ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND FLOOR. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | SOUTH GRADE TO BASEMENT MISSING HAND RAIL. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | 1ST FLOOR/GRADE AND GRADE/BASEMENT MISSING HAND RAILS | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
PROVIDE | WEST ENCLOSED WOOD PORCH HAS OPEN WOOD STUDDING. 34(13-200-260)(2) | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION ENCLOSED WOOD PORCH HAS MISSING PICKETS, LOOSE HAND RAILS, WORN, BROKEN TREADS. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | WEST ELEVATION AT GRADE HAS A WOOD CONSTRUCTED ADDITION OF ENCLOSED PORCH WITH 2X4 WALLS AND CEILING JOIST. STRUCTURE WAS BUILT WITH OUT PLANS/PERMITS. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | TUB AND SHOWER VALVE 1ST FLOOR UNIT HANDLE IS MISSING | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET AND KITCHEN FAUCET 1ST FLOOR UNIT. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET AND KITCHEN FAUCET. BASEMENT UNIT. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMITS FOR LAVATORY, TOILET, TUB AND KITCHEN FAUCET IN BASEMENT UNIT. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON LAVATORY WASTE BASEMENT UNIT. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
PROVIDE | LAVAROTY BOWL WORN BASEMENT BATHROOM. 18-29-402.1 | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT FOR VIOLATIONS. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE. IMPROPERLY INSTALLED. REMOVE MULTIPLE CONNECTIONS AND REMOVE EMT CONDUITS TO SERVICE AND INSTALL RIGID CONDUIT. INSTALL PUBLIC PANEL AND PUBLIC METER. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES IN BASEMENT APARTMENT AND EXTERIOR. ALL FIXTURES ON EXTERIOR AND SUPPORT BOXES MUST BE WEATHER PROOF. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 6348 S ELLIS AVE | PERMIT | PASSED | View | |
13.12.360 PROVIDE PERMIT TO CORRECT VIOLATIONS. | 6348 S ELLIS AVE | COMPLAINT | PASSED | View |