Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | EAST ELEVATION / TWO STORY OPEN WOOD PORCH - BUILT WITH NO PLANS ON FILE OR PERMIT OBTAINED, REMOVE. NO LANDING PROVIDED AT ATTIC EXTERIOR DOOR, 4X4 COLUNNS ON CONCRETE SLAB WITH NO FOUNDATION. WORN AND WEATHERED MEMBERS THROUGHOUT. PICKET SPACING CREATES VOIDS GREATER THAN 4 INCHES IN DIAMETER. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. DEFICIENTLY SIZED RAILING SYSTEM THROUGHOUT. 4X4 COLUMNS WITH 8 INCH LAP JOINT ANCHORED ONLY WITH NAILS. | 5617 S TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION / STAIRS FROM GRADE TO BASEMENT - MISSING HANDRAIL.EAST ELEVATION / STAIRS FROM GRADE TO FIRST FLOOR - LADDER TYPE RAILING SYSTEM WITH HORIZONTAL TIES SPACED 10 INCHES APART. | 5617 S TROY ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 1) NORTH ELEVATION / NEAR GRADE - EXTERIOR WALL STRUCTURALLY MODIFIED FOR NEW NEW DOOR OPENING. SERVICE WALK MODIFIED FOR NEW STAIR SYSTEM SERVING AS BASEMENT EGRESS. NO PLANS ON FILE OR PERMIT OBTAINED. SUBMIT PLANS AND OBTAIN FOR ALL RELATED WORK TO AUTHORIZE ALTERATION TO NORTH ELEVATION EXTERIOR MASONRY WALL AND TO NORTH SERVICE WALK. 2) NORTH, SOUTH AND EAST ELEVATIONS / ATTIC DORMERS BUILT, NO PERMIT OBTAINED. PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 5617 S TROY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF SINGLE FAMILY HOME, ENTRY REFUSED BY ATTIC TENANT / NO RESPONSE AT 1ST FLOOR / NO RESPONE AT BASEMENT. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT OF ILLEGAL DWELLING UNITS IN BASEMENT AND ATTIC. | 5617 S TROY ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | 1) EAST ELEVATION / TWO STORY OPEN PORCH BUILT FOR EGRESS PATH TO ATTIC, NO PLANS ON FILE OR PERMIT OBTAINED.2) NORTH, SOUTH AND EAST ELEVATIONS / ATTIC - DORMERS BUILT WITH NO PLANS ON FILE OR PERMIT OBTAINED. | 5617 S TROY ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTH ELEVATION / GUARDRAIL AT GRADE - DEFICIENTLY SIZED, LOOSE AND PULLING.EAST ELEVATION / STAIRS FROM GRADE TO BASEMENT - MISSING GUARDRAIL AT GRADE LEVEL. | 5617 S TROY ST | COMPLAINT | FAILED | View |