Last Modification Date: 2024-10-24 @ 2:00 AM
PIN: 11291080140000
Property Address: 7600 N SHERIDAN RD
City - Zip: CHICAGO - 60626
2023 Property Class: 315
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75031
2023 Tax District: 75005
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 42 Violations
Violation Inspector Comments Address Category Status View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW AT BASEMENT SOUTHEAST ELEVATION. 7600 N SHERIDAN RD COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS TORN SCREEN AT BASEMENT AND 2ND FLOOR SOUTHEAST. 7600 N SHERIDAN RD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST COMPLETE MANAGEMENT I.D. 7600 N SHERIDAN RD COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH IMPROPER STRINGER CONNECTION, IMPROPER BEAM AND UPRIGHT CONNECTIONS IMPROPER, UPRIGHT CONNECTIONS MISSING JOIST, RAILS LOW DEFLECT JOIST HANGERS RUSTING BEAMS AT 2ND AND 3RD FLOOR ROTTING ALSO JOISTS PLANS AND PERMITS REQUIRED FOR REPAIRS 7600 N SHERIDAN RD COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW 1ST FLOOR SOUTH 7600 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGN 3RD FLOOR WEST NOT ILLUMINATED 7600 N SHERIDAN RD COMPLAINT FAILED View
HOLDOPEN DEVICE, STAIR 3+ FLRS STAIRWELL DOORS PROPED OPEN AT ALL LEVELS 7600 N SHERIDAN RD COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH IMPROPER STRINGER CONNECTION, IMPROPER BEAM AND UPRIGHT CONNECTIONS IMPROPER, UPRIGHT CONNECTIONS MISSING JOIST, RAILS LOW DEFLECT JOIST HANGERS RUSTING BEAMS AT 2ND AND 3RD FLOOR ROTTING ALSO JOISTS PLANS AND PERMITS REQUIRED FOR REPAIRS 7600 N SHERIDAN RD COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW 1ST FLOOR SOUTH 7600 N SHERIDAN RD COMPLAINT PASSED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGN 3RD FLOOR WEST NOT ILLUMINATED 7600 N SHERIDAN RD COMPLAINT PASSED View
HOLDOPEN DEVICE, STAIR 3+ FLRS STAIRWELL DOORS PROPED OPEN AT ALL LEVELS 7600 N SHERIDAN RD COMPLAINT PASSED View
PARAPET NORTH ELEVATION / PARAPET AT 3RD STORY - SPALLING BRICKS WITH WASHED OUT MORTAR. 7600 N SHERIDAN RD COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS WITH EXPIRED OR MISSING TAGS. 7600 N SHERIDAN RD COMPLAINT FAILED View
INSECTS BED BUG INFESTATION, PROFESSIONAL EXTERMINATOR SERVICE REQUIRED. 7600 N SHERIDAN RD COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS WITH EXPIRED OR MISSING TAGS. 7600 N SHERIDAN RD COMPLAINT PASSED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGNS NOT ILLUMINATED. 7600 N SHERIDAN RD COMPLAINT PASSED View
INSECTS BED BUG INFESTATION, PROFESSIONAL EXTERMINATOR SERVICE REQUIRED. 7600 N SHERIDAN RD COMPLAINT PASSED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGNS NOT ILLUMINATED. 7600 N SHERIDAN RD COMPLAINT FAILED View
PARAPET NORTH PARAPET WALL WITH ERODING MORTAR AND SPALLING BRICK. 7600 N SHERIDAN RD COMPLAINT CLOSED View
SUBMIT 2 COPIES CRITICAL EXAM PROVIDE STRUCTURAL ENGINEERS REPORT FOR SOUTH AND EAST ELEVATIONS 100% HANDS-ON INSPECTION, SEND TO JOSE APARICIO, DEPARTMENT OF BUILDINGS, 120 N. RACINE, 60607 BL00831 7600 N SHERIDAN RD COMPLAINT CLOSED View
REPAIR EXTERIOR WALL REPAIR EXTERIOR WALL - (1) SOUTH ELEVATION NEAR SOUTHWEST CORNER PARAPET WALL SEVERE STONE DAMAGE, STONE PATCHES FAILING, MOVEMENT OF STONE WIDE JOINTS (2) LINTELS AT VARIOUS LOCATIONS RUSTING CAUSING DAMAGE TO SURROUNDING BRICK, SOME LINTELS ARE CAPPED WITH METAL, CAPS MUST BE REMOVED ARE RETAINING WATER CAUSING DAMAGE TO LINTELS (3) AT ALL ELEVATIONS WASHED OUT MORTAR (4) PARAPET WALL AND CORNICE STONES CRACKED, DAMAGED SOUTH ELEVATION (5)PLANS AND PERMITS FOR ALL REPAIRS BL00831 7600 N SHERIDAN RD COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. NO ENTRY TO APARTMENT 303 TO VERIFY COMPLAINT OF BEDBUGS. BL00831 7600 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. NO ENTRY TO APARTMENT 303 TO VERIFY COMPLAINT OF BEDBUGS.BL00831 7600 N SHERIDAN RD COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE FRONT 2ND FLOOR STAIRWELL DOOR - MISSING SELF-CLOSER.1ST FLOOR STAIRWELL DOOR - HITTING DOOR FRAME. 7600 N SHERIDAN RD COMPLAINT CLOSED View
1HR PUB.CORRIDOR IN MULT. D.U. APT. B1S - HAS HOLLOW ENTRY DOOR. 7600 N SHERIDAN RD COMPLAINT CLOSED View
CEILING HEIGHT - 7' BASEMENT APT. B1S, CEILING HEIGHT - 6'-11", LIVINGROOM PIPE HEIGHT IS 5'-5". 7600 N SHERIDAN RD COMPLAINT FAILED View
WINDOW AREA ABOVE GROUND ALL 5 BASEMENT DWELLING UNITS HAVE GLASS BLOCK WINDOWS ( 45"X31" OR SMALLER). 7600 N SHERIDAN RD COMPLAINT CLOSED View
1HR SEP-D.U. AND REST OF BLDG BASEMENT HALLWAY CEILING - ENCLOSED WITH ACOUSTIC TILES (NOT FIRE RATED MATERIAL). 7600 N SHERIDAN RD COMPLAINT CLOSED View
REPAIR EAVES EAST ROOF EAVES - PEELING PAINT. 7600 N SHERIDAN RD COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING NO RESPONSE,UNVERIFIED COMPLAINT OF MOLD IN APARTMENT B1S.UNVERIFIED DETECTORS AND CONDITIONS. 7600 N SHERIDAN RD COMPLAINT FAILED View
REPAIR CORNICE SOUTH ELEVATION CORNICE LIMESTONE WITH FRACTURES, LOOSE FRQACTURED SECTIONS, OPEN JOINTS, SOME AREAS WITH LOOSE OLDER CONCRETE SKIM COAT REPAIRS AS WELL. POSSIBLE HAZARD OVER PUBLIC WAY. OBTAIN PERMIT AND PROTECT PUBLIC WAY. 7600 N SHERIDAN RD COMPLAINT CLOSED View
FILE BLDG REGISTRATION NOT REGISTERED 2015. 7600 N SHERIDAN RD COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR WEST - HANDRAIL MISSING FROM GRADE TO BASEMENT 7600 N SHERIDAN RD COMPLAINT CLOSED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY 7600 N SHERIDAN RD COMPLAINT CLOSED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED YEAR 2015. 7600 N SHERIDAN RD COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRS (EAST) GRADE TO 3RD FLOOR - SQUEAKY STAIRS. 7600 N SHERIDAN RD COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY REAR INTERIOR STAIRS GRADE TO BASEMENT - HEADROOM IS 5'-10-1/2".(BASEMENT HAS 6 D.U.) PLANS AND PERMIT ARE REQUIRED TO PROVIDE PROPER HEADROOM. 7600 N SHERIDAN RD COMPLAINT CLOSED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED YEAR 2015. 7600 N SHERIDAN RD COMPLAINT CLOSED View
REPAIR EXTERIOR WALL WEST ELEVATION - MASONRY WALL AT GRADE - SPALLING BRICKS AND WASHED OUT MORTAR. 7600 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. 7600 N . / APARTMENT # 305 - NO ENTRY, UNABLE TO VERIFY COMPLAINT OF BUG AND ROACH INFESTATION. 7600 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ARRANGE FOR INSPECTION. INTERIOR OF BUILDING - NO RESPONSE, NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR OF BUILDING, REAR YARD, REAR PORCH. NOT ABLE TO VERIFY COMPLAINT OF DAMAGED CEILING IN APARTMENT 106. 7600 N SHERIDAN RD COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH ELEVATION / 2 STORY WOOD PORCH - COLUMN IS OUT OF PLUMB AND BOWING AT 2ND LEVEL LANDING (AS OBSERVED FROM ALLEY). PERMIT REQUIRED TO REPAIR - STRUCTURAL. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL UPON COMPLETION. 7600 N SHERIDAN RD COMPLAINT FAILED View