Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 4:18 PM
PIN: 20113070060000
Property Address: 5235 S DREXEL AVE
City - Zip: CHICAGO - 60615
2023 Property Class: 315
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70020
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 84 Violations
Violation Inspector Comments Address Category Status View
UNAPPROVED HEATING DEVICE IMPROPER HEATING DEVICE STOVES AND SPACE HEATERS ALL UNITS INSP 5235 S DREXEL AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY INSUFFICIENT HEAT IN UNIT 5235-1-63 DEGREES 5237-1-63 DEGREES 3-60 DEGREES 5235 S DREXEL AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION NOT REGISTERED 2009-2011 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR COPING COPING TILE - MISSING 5235 S DREXEL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE APPLIANCES, MATERIALS STORED IN REAR YARD. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR COPING COPING TILE - MISSING 5235 S DREXEL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE APPLIANCES, MATERIALS STORED IN REAR YARD. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES HORIZONTAL HANDRAILS ALL PORCHES ALL FLOORS 5235-37-39-41 AND 906-08 ALL HAVE COLUMN ON TOP OF BEAM CONSTRUCTION AT 5245 THE COLUMN SPLICES ARE NOT ROTTED ALL HAVE 4X4 COLUMNS OVER 24 ALL COLUMNS ARE NOT BRACKETED TO FOOTINGS NO HANDRAILS OR GUARDS AT BASEMENT OR PASSAGEWAY STEPS TREADS UNDERSIZED AT 9 1/4 INCHES 5235 S DREXEL AVE PERIODIC FAILED View
PIGEONS-NESTING BIRDS FOULING 3RD FLOOR 5235 5235 S DREXEL AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY DOUBLE KEYED GATE AT PASSAGEWAY 5235 S DREXEL AVE PERIODIC FAILED View
SERVICE WALK, PASSAGE, AREAWAY SERVICE WALK AT EAST OF 906-08 POCKMARKED DEEPLY UNEVEN 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO COMMON AREA OR 5245 2ND FLOOR 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM RAER PORCH 5235-37 IMPROPER PICKET, NO LEDGER BOLTS , REPLACE 4X4 WITH 6X6 , RAILS LOOSE , IMPROPERLY BUILTTREADS SPLIT 5239 PORCH STRINGER SCAB WORK NO FOOTING, IMPROPER PICKETS, UPRIGHT IMPROPERLY JOINT AND OUT OF PLUMB , TREADS WOOD SPLIT, 5245 PORCH IMPROPERLY PICKET , NO FOOTING NO LEDGER BOLTS LOOKOUTS NOT SEALED IN WALL , UPRIGHT IMPROPER JOINT. 5235 S DREXEL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH WINDOW PANES BROKEN. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; 2X8 JOISTS SPAN 9'-11"; 6X6 BEAMS NOTCHED, TOENAILED TO 6X6 COLUMNS;STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; SPINDLES MISSING THRU-OUT; PAINT PEELING; SCUTTLE PANEL MISSING AT #5245. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR COPING EAST ELEVATION/ COPING NEAR SOUTH END - MISSING TILES. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR LINTELS WEST ELEVATION/ LINTEL ABOVE 5235-37 ENTRANCE DOOR - SEVERELY RUSTED, BENT AND DEFLECTING.(APPROXIMATELY 70-72 INCHES IN LENGTH). PLAN AND PERMIT REQUIRED TO REPLACE DEFECTIVE LINTEL. 5235 S DREXEL AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR WEST ELEVATION/ NORTHERN AREAWAY - GATED AND DOUBLE KEY LOCKED. (UNABLE TO ENTER REAR YARD AND NORTH SIDE OF BLDG). 5235 S DREXEL AVE PERIODIC FAILED View
PARAPET EAST ELEVATION/ PARAPET WALL NEAR SOUTH END - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. 5235 S DREXEL AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION/ REAR METAL GATE 80 INCHES HIGH AND METAL OVERHEAD ROLL UP GATE 9 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS. 5235 S DREXEL AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER ID NOT COMPLETE. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION ALL APARTTMENTS AND INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF INTERCOM SYSTEM AND HALL LIGHTS NOT WORKING. UNABLE TO I9NSPECT INTERIOR STAIRWAYS, REAR PORCHES, NORTH EXTERIOR ELEVATION AND SOME POTIONS OF EAST EXTERIOR ELEVATION. UNABLE TO VERIFY COMPLIANCE ON PREVIOUS PORCH VIOLATIONS. UNABLE TO COMPLETE INTERIOR INSPECTION (OVERALL CONDITIONS) FOR 2016 ANNUAL INSPECTION. 5235 S DREXEL AVE PERIODIC FAILED View
PARAPET EAST PARAPET WALL LOOSE BRICKS AND MORTAR MISSING PORCH AREA WALL MORTAR MISSING 5239 WALL BRICKS MISSING , EAST WALL MORTAR MISSING . 5235 S DREXEL AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP. 5235 S DREXEL AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE ALL PORCH SYSTEMS 5235 S DREXEL AVE PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER CEILING COLLAPSED WATER DAMAGED BATHROOM 5245 BASEMENT 5235 S DREXEL AVE PERIODIC FAILED View
REPL DEFECTIVE BATHROOM FLOOR MISSING FLOOR TILES KITCHEN AND BATH 5245 BASEMENT 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR FLOOR ROTTED SUB FLOOR WATER DAMAGED LARGE HOLES 5235 S DREXEL AVE PERIODIC FAILED View
MICE/RODENTS EXTERMINATE FOR RODENTS 5235 S DREXEL AVE PERIODIC FAILED View
EXPOSED WIRING EXPOSED WIRES KITCHEN 5245 BASEMENT APARTMENT 5235 S DREXEL AVE PERIODIC FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT APARTMENT 5245 SUSPENDED CEILING EXPOSED JOISTS 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR SKYLIGHT 5245 LEAKING SKYLIGHT CAUSING WATER DAMAGE 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE EXTERIOR DOOR HARDWARE INOPERABLE 5245 FRONT 5235 S DREXEL AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR 5245 BASEMENT 5235 S DREXEL AVE PERIODIC FAILED View
STOP LEAKING WATER STOP WATER LEAKING INTO BATHROOM 5245 BASEMENT 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM (1535-45) GUARDRAILS LOOSE, DESIGNED WITH HORIZONTAL COMPONENTS, NO VIVIBLE FOOTINGS TREADS CRACKED AND LOOSE COLUMNS TWISTED AND BOWED NO BOLTED CONNECTIONS BEAMS AND JOIST UNDERSIZED 5235 S DREXEL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FROM 2009 THRU 2014. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR CORNICE SOUTH ELEVATION CORNICE HAS WASHED OUT MORTAR JOINTS. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 5239 TO VERIFY COMPLAINT OF MICE INFESTATION.UNABLE TO GAIN ENTRY TO VERIFY EXISTING VIOLATIONS.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS,PORCHES AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION. 5235 S DREXEL AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR WEST ELEVATION/ NORTHERN AREAWAY - GATED AND DOUBLE KEY LOCKED. (UNABLE TO ENTER REAR YARD AND NORTH SIDE OF BLDG). 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION/ ORNAMENTAL STONE CORNICE BELOW PARAPET WALL - SHIFTED MASONRY WITH WASHED OUT MORTAR.SOUT ELEVATION/ ORNAMENTAL STONE CORNICE BELOW PARAPET WALL - WASHED OUT MORTAR.PERMIT REQUIRED FOR MASONRY REPAIRS. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION/ EXTERIOR WALL - BULGING MASONRY ABOVE 3RD FLOOR WINDOWS. SPALLING BRICKS WITH WASHED OUT MORTAR ABOVE AND SOUTH OF 5235-37 S. ENTRANCE DOOR.PERMIT REQUIRED FOR MASONRY REPAIRS. 5235 S DREXEL AVE PERIODIC FAILED View
PARAPET EAST ELEVATION/ PARAPET WALL NEAR SOUTH END - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION ALL APARTTMENTS AND INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF INTERCOM SYSTEM AND HALL LIGHTS NOT WORKING. UNABLE TO I9NSPECT INTERIOR STAIRWAYS, REAR PORCHES, NORTH EXTERIOR ELEVATION AND SOME POTIONS OF EAST EXTERIOR ELEVATION. UNABLE TO VERIFY COMPLIANCE ON PREVIOUS PORCH VIOLATIONS. UNABLE TO COMPLETE INTERIOR INSPECTION (OVERALL CONDITIONS) FOR 2016 ANNUAL INSPECTION. 5235 S DREXEL AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION/ REAR METAL GATE 80 INCHES HIGH AND METAL OVERHEAD ROLL UP GATE 9 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT. 5235 S DREXEL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED FOR 2016. 5235 S DREXEL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED FOR 2016. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS. 5235 S DREXEL AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER ID NOT COMPLETE. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; 2X8 JOISTS SPAN 9'-11"; 6X6 BEAMS NOTCHED, TOENAILED TO 6X6 COLUMNS;STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; SPINDLES MISSING THRU-OUT; PAINT PEELING; SCUTTLE PANEL MISSING AT #5245. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5235 S DREXEL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE EAST ELEVATION AT GRADE GANG GRAFFITI. 5235 S DREXEL AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION/ REAR METAL GATE 80 INCHES HIGH AND METAL OVERHEAD ROLL UP GATE 9 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH AND WEST ELEVATION IN VARIOUS LOCATIONS WINDOW SILLS HAVE WASHED OUT MORTAR JOINTS. 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION ALL APARTTMENTS AND INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF INTERCOM SYSTEM AND HALL LIGHTS NOT WORKING. UNABLE TO I9NSPECT INTERIOR STAIRWAYS, REAR PORCHES, NORTH EXTERIOR ELEVATION AND SOME POTIONS OF EAST EXTERIOR ELEVATION. UNABLE TO VERIFY COMPLIANCE ON PREVIOUS PORCH VIOLATIONS. UNABLE TO COMPLETE INTERIOR INSPECTION (OVERALL CONDITIONS) FOR 2016 ANNUAL INSPECTION. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION/ ORNAMENTAL STONE CORNICE BELOW PARAPET WALL - SHIFTED MASONRY WITH WASHED OUT MORTAR.SOUT ELEVATION/ ORNAMENTAL STONE CORNICE BELOW PARAPET WALL - WASHED OUT MORTAR.PERMIT REQUIRED FOR MASONRY REPAIRS. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION/ EXTERIOR WALL - BULGING MASONRY ABOVE 3RD FLOOR WINDOWS. SPALLING BRICKS WITH WASHED OUT MORTAR ABOVE AND SOUTH OF 5235-37 S. ENTRANCE DOOR.PERMIT REQUIRED FOR MASONRY REPAIRS. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR COPING EAST ELEVATION/ COPING NEAR SOUTH END - MISSING TILES. 5235 S DREXEL AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR WEST ELEVATION/ NORTHERN AREAWAY - GATED AND DOUBLE KEY LOCKED. (UNABLE TO ENTER REAR YARD AND NORTH SIDE OF BLDG). 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR LINTELS WEST ELEVATION/ LINTEL ABOVE 5235-37 ENTRANCE DOOR - SEVERELY RUSTED, BENT AND DEFLECTING.(APPROXIMATELY 70-72 INCHES IN LENGTH). PLAN AND PERMIT REQUIRED TO REPLACE DEFECTIVE LINTEL. 5235 S DREXEL AVE PERIODIC FAILED View
PARAPET EAST ELEVATION/ PARAPET WALL NEAR SOUTH END - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR. 5235 S DREXEL AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION/ REAR METAL GATE 80 INCHES HIGH AND METAL OVERHEAD ROLL UP GATE 9 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL 5245 SOUTH WEST 1ST FL CORNER WAHED OUT MORTAR. 5235 S DREXEL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION - BASEMENT WINDOW PANE BROKEN 5235 S DREXEL AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR FRONT IRON GATE 8'X7' PERMIT REQUIRED. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR REAR (2) STAIRS GRADE TO BASEMENT NO HAND RAIL. 5235 S DREXEL AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID BASEMANT 906 NO CARBON MONOXIDE. 5235 S DREXEL AVE PERIODIC FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU 906 BASEMENT EXPOSED JOIST. 5235 S DREXEL AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT 906 NEWER WALL BUILT BY WASHER AND DRYER .PLANS AND PERMIT REQUIRED FOR THE NEWER WALLS 5235 S DREXEL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE EAST/SE REAR PORCH/1ST FLOOR - PILE OF CHARCOAL BRIQUETTES AND GRILL ON 1ST FLOOR DECK; NORTH REAR PORCH - DEEP FREEZER ON 2ND FLOOR DECK; 5235 S DREXEL AVE PERIODIC FAILED View
RAT STOP AROUND EXTERIOR EAST COURTYARD - HOLES, BURROWS NEAR SERVICEWALK NEAR SW PORCH ALLOWING RATS TO ENTER BUILDING 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS/WINDOW SCREENS - MISSING AND/OR TORN SCREENS THROUGHOUT 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME EAST/REAR ENTRY DOOR FRAMES/ALL LEVELS - PAINT PEELING 5235 S DREXEL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT ALL INTERIORS, APARTMENTS, STAIRWELLS, AND BASEMENT. UNVERIFED DETECTORS AND CONDITIONS. 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM #5239 INTERIOR STAIRWELL - LOOSE, WEAK TREADS FROM 2ND TO 3RD FLOOR 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST/EXTERIOR WALL - WASHED OUT MORTAR 5235 S DREXEL AVE PERIODIC FAILED View
PIGEONS-NESTING EAST/SE & NORTH REAR PORCHES - PIGEONS NESTING AT 3RD FLOOR 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR SKYLIGHT #5239/3RD FLOOR/INTERIOR STAIRWELL - GLASS PANE MISSING; BOARDED FROM WITHIN 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM EAST/REAR PORCHES - FOUNDATION STATUS UNKNOWN; SE REAR PORCH - DECKBOARDS CUPPING AT UPPERMOST LANDING; SW REAR PORCH - WINDERS SPLITTING FROM 2ND TO 3RD FLOOR; PAINT PEELING AT 3RD FLOOR CEILING; NORTH REAR PORCH - DECKBOARDS CUPPING AT EDGE AT 3RD FLOOR; LOOSE SPINDLE AT HANDRAIL FROM 2ND TO 3RD FLOOR; TOP RAIL CUPPING AT 3RD FLOOR RAILING SECTION; TREAD SPLITTING FROM 2ND TO 3RD FLOOR. PERMIT REQUIRED TO REPAIR REAR PORCHES. 5235 S DREXEL AVE PERIODIC FAILED View
REPUTTY WINDOW PANES EAST COURTYARD/ALL LEVELS/WINDOW TRIM - ROTTING; PAINT PEELING 5235 S DREXEL AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR NORTH/SIDE STAIRS - CRACKED, SPALLING CONCRETE TREADS; HANDRAIL MISSING FROM GRADE TO BASEMENT 5235 S DREXEL AVE PERIODIC FAILED View