Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 3:31 PM
PIN: 20084290240000
Property Address: 928 W GARFIELD BLVD
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72102
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
REPAIR BALCONY SOUTH ELEVATION / BALCONY / STEEL LINTELS - SEVERLY RUSTED AND DETERIORATED. 2ND FLOOR CONCRETE SLAB - FRACTURED. PLANS AND PERMIT REQUIRED TO REPAIR BALCONY. 928 W GARFIELD BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRWAY / SMOKE DETECTOR - MISSING. 928 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS APT 1 / SMOKE DETECTOR - LOW BATTERY CHIRPING AT TIME OF INSPECTION. 928 W GARFIELD BLVD COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER APT 1 / BATHROOM WALLS AND CEILING - WATER DAMAGE WITH BLACK SUBSTANCE ON SURFACE. 928 W GARFIELD BLVD COMPLAINT FAILED View
ROACHES BUILDING THROUHOUT - ROACHES. ROACHES - OBSERVED AT APT 1 AT KITCHEN CABINETS, NEAR STOVE AND IN REFRIGERATOR. 928 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH ELEVATION / 3 STORY WOOD PORCH. COLUMNS ERECTED ON CONCRETE FOUNDATION WITHOUT METAL BASES. 4X4 COLUMN AT STAIR STRINGER SUPPORT - ERECTED ON CONCRETE BASEMENT STAIR. COLUMN HALF LAP JOINTS MEASURE ONLY 12 INCHES AND FASTENED WITH ONLY 2 BOLTS. BEAM TO COLUMN NOTCHED OUT AT COLUMN HALF LAP JOINT. SINGLE 2X8 BEAMS FASTENED TO EXTERIOR WALL WITH NAILS ONLY. 2X8 JOISTS SPAN UP TO 11 FEET LONG. STAIR STRINGERS - FASTENED AT UPPER AND LOWER CONNECTIONS WITH NAILS ONLY. STRINGERS - CRACKED THROUGHOUT AND HAVE SCABBED PLYWOOD FASTENED TO STRINGERS. STAIRS - OPEN RISERS. GUARD RAILS - MEASURE UP TO 10 FEET 6 INCHES AND MOST RAILING SYSTEMS - FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQURED TO REPLACE REAR 3 STORY WOOD PORCH. 928 W GARFIELD BLVD COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWAY / 2ND FLOOR HANDRAIL - MISSING. 928 W GARFIELD BLVD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID APT 1 / CARBON MONOXIDE DETECTOR - MISSING. 928 W GARFIELD BLVD COMPLAINT FAILED View
MICE/RODENTS BUILDING THROUGHOUT - MICE. MOUSE HOLES AND MOUSE DROPPINGS - OBSERVED AT APT 1 IN KITCHEN CABINET AND NEAR STOVE. 928 W GARFIELD BLVD COMPLAINT FAILED View
RAT STOP AROUND EXTERIOR EAST ELEVATION AT GRADE / HOLES AND CRACKS WHERE SERVICE WALK MEETS EXTERIOR WALL. SERVICE WALK - CRACKED WITH HOLES. 928 W GARFIELD BLVD COMPLAINT FAILED View