The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | ADDRESS NOT VISIBLE. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST PORCH G TO 1ST FLR.; NO FOOTINGS,GAURD RAILS PICKETS MISSING,TREADS AD DECKING WOOD BROKEN AND SPLIT,REPLACE 4X4S WITH 6X6S [SUBMIT PERMITS TO REPLACE]. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO INTERIOR, POSSIBLE ATTIC AND BASEMENT ALTER INTO APARTMENT. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S IDENTIFICATION SIGN MISSING. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY / CAPPING - MISSING. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | ENCLOSED REAR STAIR SYSTEM / 1ST FLOOR LANDING TO GRADE - FIBERBOARD PARTITION AND PADLOCKED DOOR INSTALLED. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | TOP OF INTERIOR STAIR AND TOP OF REAR ENCLOSED STAIR SYSTEM / SMOKE DETECTORS - MISSING. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION / STAIRS FROM GRADE TO 1ST FLOOR - 4X4 POSTS ON CONCRETE SLAB, FOUNDATION UNKNOWN. ROTTING JOISTS, POSTS, TREADS, RISERS, STRINGER AND RAILING SYSTEM. LOOSE AND PULLING RAILING SYSTEM. UPPEREND OF STAIR STRINGER INADEQUATELY ANCHORED TO POSTS WITH NAILS ONLY. LADDER TYPE RAILING WITH HORIZONTAL TIES SPACED 18" APART.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF 1 STORY EXTERIOR STAIRS AT EAST ELEVATION. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | EAST ELEVATION / ENCLOSED TWO STORY PORCH - PORTIONS OF REAR PORCH HAVE BEEN ENCLOSED AND REMODELED INTO LIVING SPACE. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED AT THE REAR PORCH WITHOUT A PERMIT. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | BASEMENT / NEW STEEL BEAM AND COLUMNS - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO STRUCTURAL BEAMS AND COLUMNS. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / ENCLOSED TWO STORY WOOD PORCH - 6X6 POSTS AND 4X4 POSTS FOUNDATION UNKNOWN. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. LADDER TYPE RAILING SYSTEM THROHGOUT. GUARDRAIL AT ATTIC AT HEIGHT OF ONLY 25 INCHES. STAIR RAILING FROM ATTIC TO 2ND FLOOR AT HEIGHT OF ONLY 28 INCHES. OPEN RISERS AT STAIR FLIGHTS. UPPER AND LOWER ENDS OF STAIR STRINGERS INADEQUATELY ANCHORED WITH NAILS ONLY. STRIGERS ANCHORED TO EXTERIOR WALLS WITH NAILS ONLY. STAIR FLIGHT FROM 2ND FLOOR TO ATTIC SLOPING TOWARDS EAST. PLANS AND PERMIT REQUIRED FOR REPAIRS TO ENCLOSED TWO STORY WOOD PORCH. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | EAST ELEVATION / DOWNSPOUT - SECTION MISSING. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | BASEMENT / THROUGHOUT - ODOR OF REMOVED STAGNANT WATER REMAINS. | 13051 S HOUSTON AVE | COMPLAINT | FAILED | View |