Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | 2ND AND 3RD FLOOR WINDOWS - MISSING AND BROKEN GLASS PANES.BL00831 | 2701 W FRANCIS PL | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | ROTTED WINDOW SASHES.BL00831 | 2701 W FRANCIS PL | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | ROTTED WINDOW FRAMES.BL00831 | 2701 W FRANCIS PL | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE - UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY.BL00831 | 2701 W FRANCIS PL | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS - RETEINING WALL IS LEANING.MISSING GUARD AND HANDRAILS. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION (FRONT) - BROKEN BASEMENT WINDOW PANE. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | REAR ENCLOSED PORCH, SMOKE DETECTOR INSTALLED IN THE 2ND FLOOR. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENCLOSED PORCH - EXCESSIVE HOUSEHOLD L ITEMS STORED. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR CONCRETE PLATAFORM WITH 29" DROP - MISSING GUARD AND HANDRAILS.REAR WOOD DECK, COLUMNS ERECTED ON SOIL.UNDERSIZED 2"X6" DECK JOISTS SPAN 8'-1"LEDGER BEAM - FASTENED TO EXTERIOR WALL WITH NAILS ONLY.LOOSE HANDRAILS.GUARD AND HAND RAILING SECTIONS ARE ONLY 30" HIGH, AND ARE OF LADDER TYPE DESIGN; WITH HOIRIZONTAL RAILS 5-1/2" APART.PLANS AND PERMIT ARE REQUIRED TO REPAIR REAR WOOD DECK. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALL LEVELS ALL DWELLING UNITS - NO RESPONSE, UNABLE TO VERIFY DETECTORS, INTERIOR CONDITIONS AND OCCUPANCY. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION / EXTERIOR 1 STORY WOODEN PORCH.LEDGER BEAM,FACE NAILED ONLY TO BUILDING.COLUMNS ARE 4X4 SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.JOISTS ARE 2X6 AND SPAN 12 FEET,DRY ROTTED.STRINGERS ONLY FACE NAILED AT TOP CONNECTION,TREADS ARE LOOSE.COLUMNS SUPPORTING PORCH ROOF ARE ROTTED AT TOP CONNECTIONS.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO RESPONSE,UNVERIFIED DETECTORS,(OCCUPANCY AND CONDITIONS). | 2701 W FRANCIS PL | COMPLAINT | FAILED | View |