Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT - CEILING HEIGHT ONLY 6 FEET 8 INCHES. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT CEILING HIGHT ONLY 6 FOOT 8 INCHES IN HEIGHT. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
CHIMNEY | EAST ELEVATION//CHIMNEY-WASHED OUT MORTAR. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY HALF OPEN-HALF ENCLOSED WOODEN PORCH.4X4 COLUMN SET ON BASEMENT SLAB,FOUNDATION STATUS UNKNOWN.4X4 COLUMN SPANS 3 FLOORS,WARPED AND BOWED.COLUMNS HALF-LAP JOINTS ARE ONLY 8 INCHES,FACE NAILED ONLY.BEAM AND COLUMN CONNECTIONS PULLING APART,SECURED WITH LIGHT GAGE METAL STRAPS.JOISTS ARE ONLY FACE NAILED TO SUPPORTS.TREADS ARE SPLITTING WITH NAILS POPPING.RISERS NOT UNIFORM HEIGHT RANGING FROM 4 1/2 INCH TO 8 INCHES.STRINGERS ONLY TOE NAILED TO SUPPORTS.GUARD RAIL HEIGHT ONLY 36 INCHES,LOOSE AND PULLING.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT AND BASEMENT FURNACE ROOM-MISSING CARBON MONOXIDE DETECTOR'S. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT APARTMENT/SMOKE DETECTOR OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT FURNACE ROOM-MISSING SMOKE DETECTOR. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | BASEMENT APARTMENT- REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
HEATING PLANT SEPARATION | BASEMENT APARTMENT/REAR EGRESS GOES THROUGH ENCLOSED FURNACE ROOM. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |
RATS | BASEMENT APARTMENT AND BASEMENT FURNACE ROOM-RAT DROPPINGS. | 3313 W VAN BUREN ST | COMPLAINT | FAILED | View |