Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 4735 S PRINCETON AVE | COMPLAINT | CLOSED | View | |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSE PLUMBER TO DO PLUMBING WORK | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT INFO | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW MISSING OR BROKEN WEST ELEVATION | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SIDING MISSING WEST ELEVATION AND NORTH ELEVATION SIDING BOWING OUT SOUTH AND NORTH ELEVATIONS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FASCIA AND SOFFIT MISSING WEST ELEVATIONS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | NO SCREENS AT VARIOUS LOCATIONS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FENCE AT WEST ELEVATION NEEDS REPAIR | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARD RAILS AND HANDRAIL ON STAIRWAY TO BASEMENT EAST ELEVATION | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NO FOUNDATION UNDER POST EAST ELEVATION PORCH | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WRONG BOLT PATTERN ON EAST ELEVATION PORCH | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NO GUTTER SOUTH ELEVATION | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR IN COMMON STAIRWAY, NO WORKINGS SMOKE DETECTORS FIRST AND SECOND FLOOR DANGEROUS AND HAZARDOUS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CO2 DETECTOR FIRST AND SECOND FLOOR DANGEROUS AND HAZARDOUS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | NO LOCK ON SECOND FLOOR ENTRY DOOR | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PERFRM STRUCT ENGINEER REPAIRS | TEMPORARY SHORING IN BASEMENT, SIXTH MAIN BEAM SPLIT NEED STRUCTURAL ENGINEER REPORT | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | CARS IN BACK YARD EAST ELEVATION | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | FLOORING NEEDS REPAIR FIRST FLOOR FRONT ROOM TILES BROKEN | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLYS TO KITCHEN FAUCET, LAVATORY AND TOILET SECOND FLOOR | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER KITCHEN SINK SECOND FLOOR. | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLYS TO KITCHEN FAUCET, LAVATORY, TOILET FIRST FLOOR | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | LAVATORY DOESN'T DRAIN FIRST FLOOR | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | FOR ALTERING WASTE SYSTEM REMOVING GALVANIZE WASTE PIPE AND INSTALLING EXISTING PVC WASTE PIPE NOT TO CODE | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROVIDE | BACK PORCH NO FIRE SEPARATION 34(13-200-260)(2) | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | TUB DOESN'T DRAIN SECOND FLOOR RESTROOM | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | TANK LID MISSING SECOND FLOOR RESTROOM | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS | 4735 S PRINCETON AVE | COMPLAINT | FAILED | View |