PARAPET | NORTH AND SOUTH ELEVATION / PARAPET WALL - WASHED OUT MORTAR WITH STEP FRACTURES. SOUTH ELEVATION - VERTICAL CRACK AT FRONT FACE OF BUILDING. | 6551 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND WEST / EXTERIOR WALLS - SOUTH ELEVATON - VERTICAL CRACK AT FRONT FACE OF BUILDING. STEP FRACTURES RUNNING UNDER WINDOW SILLS. WEST ELEVATION / EXTERIOR WALL - MASONRY FRACTURES ALONG WINDOWS AND LARGE FRACTURE AND OR OPEN MORTAR JOINTS OVER ENTRY WAY. VERTICAL CRACKS FROM 3RD FLOOR TO GROUND LEVEL. STEP FRACTURES UNDER WINDOW SILLS. NORTH ELEVATION / REAR - EXTERIOR WALL COVERED IN IVY VINE.DANGEROUS AND HAZARDOUS - PROVIDE CANOPY PROTECTION OVER ENTRANCE AREA PRIOR AND DURING PERMITED MASONRY REPAIRS. | 6551 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION / 1ST TO 3RD FLOOR / WINDOW SILLS - CRACKED AND OR OPEN MORTAR JOINTS. WITH STEP FRACTURES UNDERNEATH. | 6551 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | PUBLIC WAY EGREE / PUBLIC WAY PROTECTION AND EMERGENCY REPAIRS - IMMEDIATELY PROVIDE EMERGENCY SCAFFOLDING OR PROTECTIVE CANOPY OVER THE PUBLIC WAY FOR THE PROTECTION OF PEDESTRIANS FROM UNSAFE BUILDING CONDITIONS AND PREVENT IMMINENT HARM TO PEOPLE OR PROPERTY. A BUILDING PERMIT APPLICATION COVERING THE SCOPE OF THE EMERGENCY REPAIR MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS ON THE NEXT BUSINESS DAY. A PERMIT APPLICATION FOR THE SCAFFOLDING/CANOPY MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS WITHIN 3 BUSINESS DAYS OF ERECTION. THE DEPARTMENT OF TRANSPORTATION MAY NOT ISSUE A PERMIT FOR USE OF THE PUBLIC WAY TO INSTALL SCAFFOLDING/CANOPY UNLESS A PERMIT FOR THE SCAFFOLDING/CANOPY HAS BEEN OBTAINED FROM THE BUILDING DEPARTMENT. (14A-4-401.1.1, 14A-4-401.1.2, 14A-4-404.16 THROUGH 14A-4-404.16.5, 14A-4-404.22.3 AND 14B-33-3306) | 6551 N SACRAMENTO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT OF BUILDING / LINTELS - RUSTED AND SAGGING. THERE ARE VOLUMETRIC EXPANSION MASONRY FRACTURES AND OR BULGING BRICKS AT LOAD AND BEARING SECTIONS. PERMITS REQUIRED FOR LINTEL REPLACEMENT OVER 6FT. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL | 6551 N SACRAMENTO AVE | COMPLAINT | FAILED | View |