Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S I.D. SIGN NOT POSTED | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | NORTH ELEVATION - DOWN SPOUT NOT EXTENDED TO GRADE | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | NORTH ELEVATION - FRONT ENTRY DOOR HAS CRACKED SIDE LITES | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | WEST ELEVATION - CHIMNEY CAP MISSING | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
PARAPET | WEST, EAST ELEVATIONS - WASHED OUT MORTAR AT PARAPET WALL | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION - REAR GATE CHAINED, PAD LOCKED; FURNITURE STORED AT 2ND FLOOR | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH ELEVATION - GUARD RAIL MISSING AT GRADE FOR BASEMENT AREA WAY | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION - REAR PORCH - 2X8 JOISTS SPAN 12'-2"; BOLTS MISSING AT STRINGERS RAILS; EAR OF STRINGER BETWEEN LANDING AND 2ND FLOOR HAS BEEN SPLICED; STEEL ANGLE BRACKETS MISSING AT COLUMN/BEAM CONNECTIONS; RAIL HEIGHT IS ONLY 36". SPINDLE LOOSE AT 2ND FLOOR; HAND RAIL MISSING FROM GRADE TO BASEMENT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - CRACKS IN EXTERIOR WALL, WASHED OUT MORTAR NEAR 6X6 BEAMS | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | SOUTH ELEVATION - MISSING SECTIONS OF FASCIA BOARDS, GUTTERS, DOWN SPOUT ARE MISSING | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT - LAUNDRY AREA - WALLS COVERED WITH BLACK BROWN SUBSTANCE | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
SELF-CLOSE CLASS B FIRE DOOR | VESTIBULE - CLOSER MISSING ON FRONT ENTRY DOOR | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | VESTIBULE - FRONT ENTRY DOOR JAMB CHIPPED NEAR LOCK SETS | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
INSTALL DOOR VIEWING DEVICE | 1ST, 2ND FLOOR VIEWING DEVICE MISSING AT FRONT ENTRY DOOR | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR STAIRWELL - SMOKE DETECTOR BEEPING - LOW BATTERY - AT TIME OF INSPECTION | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE - UNABLE TO INSPECT ENTIRE BASEMENT REGARDING MISSING DRYWALL, UNABLE TO INSPECT 2ND FLOOR APARTMENT UNVERIFIED DETECTORS | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - WASHED OUT MORTAR NEAR 6X6 BEAM AT 2ND FLOOR. | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - WASHED OUT MORTAR | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - WASHED OUT MORTAR | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - CAP MISSING | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - 2X8 JOISTS SPAN 12'-2"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; EAR OF STRINGER BETWEEN 1ST AND 2ND FLOOR HAS BEEN SPLICED; BEAMS TOENAILED TO COLUMNS; RAIL HEIGHT IS ONLY 36"; SPINDLE LOOSE AT 2ND FLOOR; HANDRAIL MISSING FROM GRADE TO BASEMENT; 2ND FLOOR DECK AND LANDING WEAK, UNSTABLE. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT ENTRY DOOR - JAMB CHIPPED NEAR LOCKSETS; NOT SECURE. | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - SERVICE DOOR ROTTING; GUTTERS AND DOWNSPOUT MISSING | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN NOT POSTED | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | 18'X20' GARAGE ERECTED WITHOUT BENEFIT OF PERMIT 14A-3-306-1 14A-4-401-1 | 3425 W EVERGREEN AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | BASEMENT - LAUNDRY AREA - EXPOSED WIRES AT JUNCTION BOX AT CEILING | 3425 W EVERGREEN AVE | COMPLAINT | CLOSED | View |