Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 2:20 PM
PIN: 20211240170000
Property Address: 6640 S UNION AVE
City - Zip: CHICAGO - 60621
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72130
2023 Tax District: 72082
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 51 Violations
Violation Inspector Comments Address Category Status View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR AT BASEMENT APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR AT BASEMENT APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR AT BASEMENT APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR AT BASEMENT APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
BASEMENT, DISCONTINUE BASEMENT STORAGE AREA BEING USED AS AN APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT CEILING MISSING PLASTER VARIOUS LOCATIONS AND OPEN FLOOR JOISTS. 6640 S UNION AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CO2 IN BASEMENT FURNACE. 6640 S UNION AVE COMPLAINT FAILED View
1-HR STAIR ENCLOSURE, <3 STORY REAR ENCLOSED STAIRWELL NO FIRE RESISTANT ENCLOSURE. 6640 S UNION AVE COMPLAINT FAILED View
UNDERSIDE STAIR 1HR FIRE RES REAR ENCLOSED STAIRS UNDERSIDE NO FIRE PROTECTION. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
CHIMNEY CHIMNEY MISSING CAP. 6640 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION REFUSED ENTRY TO BASEMENT- UNABLE TO VERIFY DETECTORS AND OCCUPANCY. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2ND MISSING SMOKE DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
CARB MONOX DETECT IN ASSEMBLY 2ND MISSING CARBON MONOXIDE DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR ENTRANCE DOOR BROKEN, FOYER DOOR BROKEN PANE. 6640 S UNION AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID SIGN POSTED. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL ENCLOSED REAR PORCH MISSING SIDING. 6640 S UNION AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID SIGN POSTED. 6640 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 1ST FLOOR/2ND FLOOR AND ENCLOSED PORCH. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS COMMON STAIRWAY MISSING SMOKE DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN ORIGINAL CONSTRUCTION OF BASEMENT WAS FOR THE MECHANICALS AND STORAGE CONSTRUCTION HAS NON LOAD BEARING PARTITION WALLS FORMING A LIVING ROOM, DINING ROOM, KITCHEN, BATH, AND BEDROOM. 6640 S UNION AVE COMPLAINT FAILED View
VENT SYSTEM TO PRVNT BACK PRES NO VENT ON 1.5" KITCHEN SINK WASTE BASEMENT APARTMENT. 6640 S UNION AVE COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMIT FOR ELECTRICAL SYSTEM INSTALLED TO BASEMENT WITHOUT PERMITS. 6640 S UNION AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# MISSING OWNER POSTING. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BASEMENT HAS NON-WORKING SMOKE DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT MISSING CO DETECTOR. 6640 S UNION AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR EAST HAS BROKEN WINDOW PANE. 6640 S UNION AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY BASEMENT DOOR SWINGS INTO COMMON HALLWAY CAUSING AN EGRESS ISSUE. WHEN OPEN DOOR, PROHIBITS EGRESS FROM 1ST FLOOR APARTMENT DANGEROUS CONDITION. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM NORTH STAIRS GRADE TO BASEMENT MISSING HANDRAIL. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST ENTRY DOOR MISSING DEAD-BOLT. 6640 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH EXTERIOR WALL MISSING AND LOOSE SIDING. 6640 S UNION AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT HAS GAS FIRED FURNACE IN DINING ROOM HAVING A TOTAL LACK OF FIRE SEPARATION 34 (13-196-172) 6640 S UNION AVE COMPLAINT FAILED View
REMOVE BASEMENT GAS FIRED FURNACE HAS STORED FLAMMABLE MATERIALS AROUND AND ON FURNACE. DANGEROUS CONDITION 15-4-880. 6640 S UNION AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT MISSING OR LACKING FIRE SEPARATION IN CEILING. BROKEN PLASTER WITH EXPOSED LATH. 34(13-196-710) 6640 S UNION AVE COMPLAINT FAILED View
WORK NOT ALLOWED CHAIN LINK FENCE OVER 5 FEET. REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT. 6640 S UNION AVE COMPLAINT FAILED View
BASEMENT, DISCONTINUE ORIGINAL CONSTRUCTION OF BASEMENT WAS FOR THE MECHANICALS AND STORAGE. CURRENT CONSTRUCTION HAS NON LOAD BEARING PARTITION WALLS FORMING A LIVING ROOM, DINING ROOM, KITCHEN, BATH AND BEDROOM. STOP USING BASEMENT AS DWELLING UNIT. RESTORE TO ORIGINAL USE. (13-196-740, 13-200-120, 13-200-210-13-200-240) 6640 S UNION AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR IN ORDER TO KEEP BASEMENT AT CURRENT USE, PROVIDE PROPER PLANS AND PERMITS.OR OBTAIN PERMIT TO DE-CONVERT. 6640 S UNION AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLY LIN EAT KITCHEN SINK, LAVATORY, TOILET AT BASEMENT. 6640 S UNION AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET TUB MISSING ESCUTCHEON AT BASEMENT. 6640 S UNION AVE COMPLAINT FAILED View
REMOVE REMOVE 2" FERNEO COUPLING AT 2" WASTE STACK IN BASEMENT WEST ELEVATION. 18-29-705 6640 S UNION AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMIT FOR WORK. 6640 S UNION AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN LICENSED PLUMBER FOR VIOLATIONS. 6640 S UNION AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND VANDALIZED POWER SERVICE WITH OPEN PANEL. DANGEROUS CONDITION. 6640 S UNION AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES IN BASEMENT REAR ENTRY DOOR. 6640 S UNION AVE COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS TO OPEN JUNCTION BOXES. DANGEROUS CONDITION. 6640 S UNION AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS THROUGHOUT BASEMENT. DANGEROUS CONDITION. 6640 S UNION AVE COMPLAINT FAILED View
ROACHES APT. 2 ROACHES. 6640 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION TENANT REFUSE ENTRY, UNABLE VERIFY COMPLAINT SR 131787277. 6640 S UNION AVE COMPLAINT FAILED View
PRV BALLCOCK,VB,OR AIR GAP SILLCOCK MISSING VACUUM BREAKER EAST ELEVATION. 6640 S UNION AVE COMPLAINT FAILED View
13.12.360 PROVIDE PERMIT TO CORRECT VIOLATIONS. 6640 S UNION AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE COMMON HALLWAY HAS DRUG WRAPPERS. 6640 S UNION AVE COMPLAINT FAILED View