Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | OWNERS ID SIGN IS NOT POSTED. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS - WASHED OUT MORTAR. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH WASHED OUT MORTAR. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR COPING | EAST STONE COPING - WASHED OUT MORTAR | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EAST -WASHED OUT MORTAR | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH WASHED OUT MORTAR, SPALLING BRICKS BUILDING FORWARD ABOVE 1432 SERVICE WALK MISSING CAP SOUTH WASHED OUT MORTAR MISSING CAP PERMIT IS REQUIRED FOR REPAIRS OR REPLACEMENTS. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS- ROTTED FRACTURED RISERS LOOSE THREADS ROTTED DECK. LOOSE HAND AND GUARD RAIL HEIGHT, STRUCTUAL MEMBERS ARE ENCLOSED WITH PLYWOOD UNABLE TO VERIFY CONDITIONS. IMPROPER CONNECTIONS MOST MEMBERS ARE TOENAILED TOGETHER AND ARE SSEPERATING AT THE CONNECTIONS PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENTS | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | FRONT ENTRY LIGHT FIXTURE IS MISSING A BULB OPEN SOCKET | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT GATES DOUBLED KEYED CYCLINDER LOCKS. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRAON AND REAR YARD AND REAR STAIRS FROM G TO B ACCUMULATION OF MISC. TRASH AND JUNK. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR YARD DOG FENCES | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR YARD MUD AND STANDING WATER | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR WOODEN GATES IS BROKEN AND MISSING A SECTION. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- CLOLUMNS ARE RESTED ON CONCERETE, FOUNDATION STATUS IS UNKNOWN COLUMNS ARE OUT OF PLUMB AND PULLING AWAY FROM THE BEAMS. ONLY A 4X6 CENTER BEAM PROPPED U WITH A 4X4 MEMEBER AT (1) LOOSE TREADS AND HAND/GUARD RAILS. GUARDRAILS ONLY 34" IN HEIGHT WITH MISSING PICKETS DECK AT (1) IS SEVERLY PITCHED DOWNWARD AWAY FROM THE BUILDING. IMPROPER CONNECTIONS MOST MEMBERS ARE TOENAILED TOGETHERAND ARE SEPERATING AT THE CONNECTION PLAND AND PERMITS ARE REQUIRED FOR REAPIRS OR REPLACEMTNS. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY- BROKEN THREADS AND RISER AT 2 PERMIT IS REQUIRED FOR REPAIRS. | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BSMT. NO RESPONSE APT 1 REFUSED ENTRY UNVERFIED DECTS. OCCCUPANCY AND CONDITIONS, | 1434 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |