Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:30 PM
PIN: 19154170030000
Property Address: 6109 S KILDARE AVE
City - Zip: CHICAGO - 60629
2023 Property Class: 205
2023 Township: 72 - Lake
2023 Neighborhood: 72030
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 21 Violations
Violation Inspector Comments Address Category Status View
REPAIR WINDOW SILLS FRONT AND NORTH ELEVATIONS/ ATTIC AND 1ST FLOOR WINDOW SILLS - WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT PASSED View
CHIMNEY NORTH CHIMNEY - SPALLING BRICKS NEAR TOP AND WASHED OUT MORTAR AT MULTIPLE LOCATIONS. 6109 S KILDARE AVE COMPLAINT PASSED View
MAINTAIN WINDOW SASH SOUTH AND NORTH ELEVATIONS/ WINDOW SASHES - ROTTED WITH PEELING PAINT. 6109 S KILDARE AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR FRAME SOUTH ELEVATION. EXTERIOR DOOR FRAME - BRICK MOULDING IS SEPARATING FROM JAMB CAUSING LARGE GAP WITH EXPOSED BRICK. 6109 S KILDARE AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM SOUTH INTERIOR STAIRWAY/ 1ST FLOOR TO ATTIC/ STAIR RAILING SECTION - BROKEN AND MISSING SECTION AND BALUSTERS. 6109 S KILDARE AVE COMPLAINT PASSED View
EGRESS ATTIC APT. - ONLY ONE MEANS OF EGREES AT SOUTH ELEVATION. 6109 S KILDARE AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC AND BASEMENT OR RESTORE BUILDING TO THE ORIGINAL STATE.SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 6109 S KILDARE AVE COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC} INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. 6109 S KILDARE AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT GRADE TO 1ST FLOOR EXTERIOR STAIORWAY - BROKEN AND SPALLING CONCRETE,REAR GRADE TO 1ST FLOOR EXTERIOR STAIRWAY - RAILINGS - ONLY 39 INCHES HIGH; PICKETS SPACED 6 INCHES APART. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION/ EXTERIOR WALL - WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH SOUTH AND NORTH ELEVATIONS/ WINDOW SASHES - ROTTED WITH PEELING PAINT. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS FRONT AND NORTH ELEVATIONS/ WINDOW SILLS - WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS REAR ELEVATION/ BASEMENT WINDOW - BOARDED UP. 6109 S KILDARE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT GRADE TO 1ST FLOOR EXTERIOR CONCRETE STAIRWAY/ STEPS - SPALLING AND CRACKED CONCRETE.REAR GRADE TO 1ST FLOOR EXTERIOR WOOD STAIRWAY/ RAILINGS - LOOSE AND PULLING; ONLY SCREWED TO COLUMND AND POSTS. PICKETS ARE OVERSPANNED' SPACED 5 TO 7 INCHES APART. 6109 S KILDARE AVE COMPLAINT PASSED View
CHIMNEY NORTH CHIMNEY - SPALLING BRICKS WITH WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH AND NORTH ELEVATIONS/ EXTERIOR WALLS - WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS FRONT, NORTH AND SOUTH ELEVATIONS/ WINDOW SILLS - WASHED OUT MORTAR. 6109 S KILDARE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH SOUTH AND NORTH ELEVATIONS/ BASEMENT WINDOW SASHES - ROTTED WITH PEELING PAINT. 6109 S KILDARE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT GRADE TO 1ST FLOOR EXTERIOR STAIRWAY - BROKEN AND CRACKED CONCRETE. 6109 S KILDARE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ENTRY REFUSED BY 1ST FLOOR TENANT, BASEMENT AND ATTIC - NO RESPONSE. UN ABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. 6109 S KILDARE AVE COMPLAINT FAILED View