Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR LINTELS | FRONT BALCONY LINTELS OVER 2- RUSTED. BL00831 | 1515 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRACTURES, OPEN MORTAR JOINTS OFF OF FRONT BALCONY LINTELS AT 2. MOST SIGNIFICANT ON NORTH ELEVATION WHERE FRACTURES AND SHIFTING BRICK ARE RESULTING FROM LINTEL CONDITION. NORTH ELEVATION WITH SHIFTED BRICK, MISSING BRICK, ERODING MORTAR. NORTH ELEVATION TOWARD REAR- SPALLING BRICK, OPEN MORTAR JOINTS. BL00831 | 1515 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | OPEN SILL JOINTS THROUGHOUT. BL00831 | 1515 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- BEAM AND COLUMN JOINTS AT FIRE CUTS SEPARATING. POSTS, BEAMS, COLUMNS, JOISTS, RAILS, STRINGERS- ALL MEMBERS ANCHORED WITH NAILS ONLY. 34 1/2'' GUARD RAILS. 2X8 JOISTS SPAN UP TO 14' INSTALLED AT 20'' CENTERS. LOOSE AND DEFLECTING RAILS. LOOSE AND BUCKLING, ROTTING DECKING. DEFLECTING STRINGERS/ TREADS AT WINDERS. LOOSE TREADS. 6X6 LOKKOUT BEAMS SPAN UP TO 10' 6''. RAILS SPAN UP TO 7' 9'' WITH NO INTERMEDIATE SUPPORT. SINGLE 2X8 HEADERS SPAN 7' 3''. FOTTING STATUS NOT KNOWN. SOUTH EAST COLUMN OUT OF PLUMB. CRACKED STRINGERS. NO HAND RAIL TO BASEMENT. OBTAIN COMPLETE PLAN AND PERMIT. | 1515 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT BALCONY LINTELS OVER 2- RUSTED. | 1515 W TOUHY AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | FRACTURES, OPEN MORTAR JOINTS OFF OF FRONT BALCONY LINTELS AT 2. MOST SIGNIFICANT ON NORTH ELEVATION WHERE FRACTURES AND SHIFTING BRICK ARE RESULTING FROM LINTEL CONDITION. NORTH ELEVATION WITH SHIFTED BRICK, MISSING BRICK, ERODING MORTAR. NORTH ELEVATION TOWARD REAR- SPALLING BRICK, OPEN MORTAR JOINTS. | 1515 W TOUHY AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | OPEN SILL JOINTS THROUGHOUT. | 1515 W TOUHY AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH- BEAM AND COLUMN JOINTS AT FIRE CUTS SEPARATING. POSTS, BEAMS, COLUMNS, JOISTS, RAILS, STRINGERS- ALL MEMBERS ANCHORED WITH NAILS ONLY. 34 1/2'' GUARD RAILS. 2X8 JOISTS SPAN UP TO 14' INSTALLED AT 20'' CENTERS. LOOSE AND DEFLECTING RAILS. LOOSE AND BUCKLING, ROTTING DECKING. DEFLECTING STRINGERS/ TREADS AT WINDERS. LOOSE TREADS. 6X6 LOKKOUT BEAMS SPAN UP TO 10' 6''. RAILS SPAN UP TO 7' 9'' WITH NO INTERMEDIATE SUPPORT. SINGLE 2X8 HEADERS SPAN 7' 3''. FOTTING STATUS NOT KNOWN. SOUTH EAST COLUMN OUT OF PLUMB. CRACKED STRINGERS. NO HAND RAIL TO BASEMENT. OBTAIN COMPLETE PLAN AND PERMIT. | 1515 W TOUHY AVE | COMPLAINT | PASSED | View |
WORK CONTRARY TO PERMIT | PERMIT # 100440771 ISSUED 6-20-2012 FOR " REPLACE REAR TWO STORY OPEN WOOD PORCH " , WORK CONTRARY TO APPROVED PLANS . ARCHITECT'S LETTER NOT SUFFICIENT FOR REVISIONS - COLUMN SPLICES SHOWN ON PLANS ABOVE DECK - BUILT WITH COLUMNS BELOW DECK - CONTRARY TO APPROVED PLANS. RIM BEAMS - MISSING BOLTS. INSUFFICIENT NUMBER OF LEDGER BOLTS - MISSING AT ENDS. SOME STRINGER CONNECTIONS ONLY NAILED TO COLUMNS AND HEADER JOISTS.STRINGER PIER AT GRADE - MISSING. GUARDRAILS AT GRADE TO BASEMENT AT GRADE - MISSING. HANDRAIL - GRADE TO BASEMENT - MISSING. REVISED PERMIT AND PLANS REQUIRED . | 1515 W TOUHY AVE | PERMIT | PASSED | View |