SUPPLY HOT WTR MIN TEMP 120DEG | WATER TEMPERATURE 69 DEGREES | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS - VERTICAL CRACKS | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
PARAPET | PARAPET WALLS - SPALLING BRICKS AND MORTAR | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR AREAWAY WALL | REAR RETAINING WALL AT BASEMENT BROKEN CONCRETE | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR OPEN WOOD PORCH - IMPROPER FOOTINGS AT COLUMNS; 2X6 JOISTS ARE UNDERSIZED FOR SPAN OF DECKS; BEAM TO COLUMN CONNECTIONS NAILED; GAP AT BEAM TO COLUMN CONNECTION; ROTTED WOOD AT STAIR STRINGERS,DECKING AND GUARDRAILS; PICKETS MISSING; GUARDRAILS LESS THAN 42" HIGH;ROOF AREA LOOSE SHEET METAL; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OF PORCH | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH - SIDE WALLS BUCKLED,BROKEN CONCRETE; TREADS AND RISERS BROKEN CONCRETE; PERMIT REQUIRED FOR REPAIRS | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR DOOR MISSING KNOBS; REAR BASEMENT DOOR MISSING KNOBS AND LOCK | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | FRONT GUTTER FILLED WITH DEBRIS; DOWNSPOUT MISSING | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | REAR GUTTER RUSTED WITH HOLES; DOWNSPOUT DISCONNECTED AT ROOF; RUSTED WITH HOLES | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | BASEMENT CEILING BROKEN AND MISSING PLASTER; WALLS DAMAGED | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | BROKEN AND UNEVEN CONCRETE THRU-OUT; HOLES IN FLOOR | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR 2ND FLOOR - BROKEN WINDOW PANE | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | SEVERAL WINDOWS BOARDED UP; WINDOW OPENING ALTERED FROM ORIGINAL SIZE; FRAMES HAVE PEELING PAINT AT VARIOUS LOCATIONS | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | DEFECTIVE KNOB LOCK | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPAIR DOOR FRAME, MULLION | DOOR FRAME DAMAGED AT LOCK SIDE | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
INSTALL DEAD BOLT LOCK | NO DEAD BOLT LOCK | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
INSTALL DEAD BOLT LOCK | 2ND FLOOR REAR DOOR - NO DEAD BOLT LOCK | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | MISCELLANEOUS ITEMS STORED UNDER PORCH AND ON 1ST AND 2ND FLOOR DECKS | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | BASEMENT - EXCESSIVE FUNK AND DEBRIS THRU-OUT | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | BASEMENT FLOOR - EXCESSIVE WASTE AND RAW SEWAGE THRU-OUT | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE SOIL PIPING | BASEMENT FLOOR COVERED WITH WASTE FROM TOILETS; RAW SEWAGE | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
CLEAN CATCH BASIN | BASEMENT FLOOR COVERED WITH RAW SEWAGE, HUMAN FECES | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR CONCRETE STAIRWAY - STEPS SPALLING. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR OF BUILDING - BRICKS SPALLING WITH OPEN MORTAR JOINTS. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING THROUGH OUT. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | RECENTLY BUILT 2 STORY STEEL PORCH - UNDER PERMIT # 100406992 ISSUED ON 11/22/2011, PLANS AND PERMIT NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 3239 W CARROLL AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 2ND FLOOR REAR DOOR - NO VIEWING DEVICE | 3239 W CARROLL AVE | COMPLAINT | PASSED | View |