Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:47 PM
PIN: 13364180100000
Property Address: 1733 N FAIRFIELD AVE
City - Zip: CHICAGO - 60647
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77030
2023 Tax District: 77162
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 15 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT POSTED 1733 N FAIRFIELD AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS SCREENS MISSING 1733 N FAIRFIELD AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH: GUARD RAILS ON DECK AND STAIRS NOT 42 INCHES HIGH, DECK LEANING, JOIST SPACED TOO FAR APART, 2X12 APPROXIMATELY 32 INCHES ON CENTER; PERMIT REQUIRED FOR REPAIRS ON REPLACEMENT-PICKETS SPACED TOO FAR APART ON STAIRS 1733 N FAIRFIELD AVE COMPLAINT FAILED View
RATS-ELEVATE MATERIAL 18" REAR YARD: WOOD PILED 1733 N FAIRFIELD AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS REAR: CENTER METER COVER TAPED ON SHEET METAL 1733 N FAIRFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL ATTIC AT EAST: SIDING MISSING 1733 N FAIRFIELD AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE NO PEEPHOLES, FRONT DOORS 1733 N FAIRFIELD AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR WOOD SHED BUILT UNDER FRONT STAIRS 1733 N FAIRFIELD AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR REAR GATE: DOUBLE KEY LOCKED-REQUIRES INTERNAL THUMB LATCH 1733 N FAIRFIELD AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS STORM GLASS BROKEN, 2ND FLOOR AT SOUTH AT REAR 1733 N FAIRFIELD AVE COMPLAINT FAILED View
REPAIR BALCONY EAST WOOD BALCONIES AT 2ND AND 3RD FLOORS: NO PERMITS/PLANS ON FILE, APPROXIMATE SIZE 4 BY 8 FEET-NO SUPPORT, NO UPRIGHTS, BALCONY SYSTEM IS HANGING BY CHAINS FROM BUILDING, POOR CONSTRUCTION TECHNIQUE-2X6 JOIST UNDERSIZED, LEDGER BOARD-INSUFFICIENT BOLTS 1733 N FAIRFIELD AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD: HIGH WEEDS 1733 N FAIRFIELD AVE COMPLAINT FAILED View
DEMO DEBRIS REAR YARD: ROCKS AND BRICKS PILED 1733 N FAIRFIELD AVE COMPLAINT FAILED View
REPAIR OR REPLACE DOWNSPOUTS MISSING TWO LOWER SECTIONS AT SOUTH , SECTION 18-29-1101-2.1 1733 N FAIRFIELD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION SR#07-00809507 NO ENTRY ON MOLD COMPLAINT 1733 N FAIRFIELD AVE COMPLAINT FAILED View