Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 9:24 PM
PIN: 20102130300000
Property Address: 4822 S EVANS AVE
City - Zip: CHICAGO - 60615
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70112
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
DEBRIS, EXCESSIVE REAR UNDER PORCH - EXCESSIVE JUNK AND DEBRI. 4822 S EVANS AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED. 4822 S EVANS AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL EAST ELEVATION 2ND FLOOR WINDOW AREA - STONE MULLIONS BULGING OUTWARDS, FRACTURES, MASONRY PERMIT REQUIRED FOR REPAIRS. 4822 S EVANS AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED. 4822 S EVANS AVE COMPLAINT FAILED View
REPLACE D&H PORCH REAR 2 STORY WOOD PORCH -ROTTED WOOD.SOME 6X6 COLUMNS SET IN DIRT, FOUNDATION STATUS UNKNOWN.6X6 COLUMNS DOUBLE NOTCHED AT BEAM TO COLUMN CONNECTION AREA.12 INCH LAPJOINTS ON COLUMNS LOCATED AT BEAM CONNECTION.MIDDLE 6X6 COLUMN IS BOWED OUTWARDS.2X8 JOIST SPAN 12 FEET.STRINGERS WRAPPED UNDER HEADER AND NAILED TO JOIST.6X6 LOOKOUT BEAMS SPAN 7 FEET, MISSING TIE STRAPS AT BUILDING CONNECTION AND NAILED TO COLUMNS.BROKEN HANDRAIL FROM LANDING TO 2ND FLOOR.2X8 JOIST AT LANDING NAILED TO BEAM.2X8 BEAMS FOR LANDING NAILED TO COLUMNS.STAIRS LEANING, DECK WITH EXCESSIVE SLOPE.PLANS AND PERMIT REQUIRED. 4822 S EVANS AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTEIROR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY, UNABLE TO VERIFY COMPLAINT OF MICE. 4822 S EVANS AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING /BASEMENT APT. - ENTRY REFUSED. 1ST. AND 2ND. FL. APTS. - NO RESPONSE; UNABLE TO VERIFY DETECTORS, AND CONDITIONS;UNABLE TO INSPECT INTERIOR STAIRWAY; 4822 S EVANS AVE COMPLAINT FAILED View
PARAPET & COPING FRONT ELEVATION /METAL PARAPET WALL AND COPING - RUSTED, WITH LARGE HOLES. 4822 S EVANS AVE COMPLAINT FAILED View
CHIMNEY SOUTH ELEVATION /CHIMNEY - LOOSE BRICK, WITH WASHED OUT MORTAR. 4822 S EVANS AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR. 4822 S EVANS AVE COMPLAINT FAILED View
REPAIR LINTELS FRONT ELEVATION /STONE [ENTRY DOOR] LINTEL - FRACTURED, BROKEN, CRACKED, HANGING DOWNWARD, WITH WASHED OUT MORTAR.MASONRY PERMIT REQUIRED TO REPLACE. 4822 S EVANS AVE COMPLAINT FAILED View
REPAIR AREAWAY WALL SOUTH ELEVATION /AREAWAY WALLS - WASHED OUT MORTAR. CEILING - COMBUSTIBLE MATERIAL INSTALLED. 4822 S EVANS AVE COMPLAINT FAILED View
REPLACE D&H PORCH PLANS AND PERMIT REQUIRED TO REPLACE:REAR ELEVATION /2 STORY WOOD DANGEROUS & HAZARDOUS PORCH WITH ROOF.FOUNDATIONS /COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN; FOUNDATIONS /BASES FORMED BY CONCRETE POURED IN AROUND COLUMN; FOUNDATION STATUS UNKNOWN;COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 12 INCHES, WITH ONLY 2 BOLT USED OF 3/8 INCHES IN DIAMETER; 6X6 COLUMNS - SPACED UP TO 10 FEET 6 INCHES APART; COLUMNS /OVER NOTCHED WITH OVERLAP, FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 4 INCHES APART; LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS/SCREWS ONLY.BEAMS /ROTTING, SAGGING AT FIRE CUT; PULLING OUT OF FIRE CUTS; IMPROPERLY SUPPORTED AT FIRE CUTS; BEAMS TOE NAILED TO COLUMNS; BEAMS /WOOD SHIMS LEFT IN PLACE UNDERNEATH BEAMS INSIDE THE BEAM POCKET; BEAMS /ROTTED, SAGGING. ROOF BEAMS /STACKED ON TOP OF COLUMNS, FASTENED WITH NAILS/SCREWS ONLY; ROOF /JOISTS ¿ FASTENED TO LOOKOUTS WITH NAILS/SCREWS ONLY;DECK JOISTS /UNDERSIZED 2X8 DECK JOISTS SPAN 10 FEET 6 INCHES; DECK JOISTS /FASTENED TO HEADERS, WITH NAILS ONLY; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; STRINGERS WEAK, OVER CUT, ROTTED, CRACKED, BROKEN. STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 9 INCHES TO 7 1/2 INCHES TO 6 1/2 INCHES; STAIRS /TREADS AND RISERS - WORN OUT, CRACKED, BROKEN, ROTTED, WEAK; PORCH UNSTABLE, LANDING ¿ EXCESSIVE PULLING, SWAYING; DECKING /DECK BOARDS, BUCKLED, ROTTED, LOOSE; RAILINGS /GUARD RAILING SECTIONS ONLY 33 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ONLY 24 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY;CONCENTRATED LOAD /ITEMS BEING STORED ON THE PORCH INCLUDE: CHAR COAL GRILLS, PLASTIC CONTAINERS OF JUNK;PLANS AND PERMIT REQUIRED TO REPLACE:REAR ELEVATION /2 STORY WOOD DANGEROUS & HAZARDOUS PORCH WITH ROOF. 4822 S EVANS AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT ELEVATION /METAL GUARD RAIL SECTIONS ONLY 33 INCHES HIGH, WITH PICKETS SPACED UP TO 9 INCHES APART. 4822 S EVANS AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR UNDER PORCH - EXCESSIVE JUNK AND DEBRI. 4822 S EVANS AVE COMPLAINT FAILED View
CHIMNEY CAPPING SOUTH ELEVATION /CHIMNEY CAPPING - MISSING. 4822 S EVANS AVE COMPLAINT FAILED View