Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR REINSPECTION REGAR | RECENTLY BUILT REAR PORCH. PLANS AND PERMIT NOT AVAILABLE FOR REVIEW AT TIME OF INSPECTION. | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 BEAMS NOTCHED, TOENAILED TO 6X6 COLUMNS; 2X8 JOISTS SPAN 12'-0"; STRINGERS INADEQUATELY SUPPORTED COLUMNS; SPLICE JOINTS AT 2ND FLOOR ARE WITHIN 1" - 3 1/2" OF BEAM/COLUMN CONNECTIONS; RAILS LOOSE THRU-OUT, PULLING AWAY FROM EXTERIOR WALL AT LANDING BETWEEN 1ST AND 2ND FLOORS, UNSECURED, UNSTABLE; LOOSE DECKBOARDS AT SOUTH END OF 1ST FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNABLE TO INSPECT 2ND FLOOR APARTMENT, STAIRWELL, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |
CIRCUIT ONE UNIT ONLY | INTERMINGLING AND LACK OF PUBLIC PANEL 3 DY'S PROVIDE ADDITIONAL PANEL AND METERING TO SERVE COMMON AREA LOADS | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |
TENANT ACCESS TO SERVICE | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View | |
STRAP SERVICE CONDUIT | UNDER PORCH, SERVICE CONDUIT DAMAGED AND NOT SUPPORTED | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | METER ASSEMBLY BROKEN AND RUSTED | 5311 S MARYLAND AVE | COMPLAINT | PASSED | View |