Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEBRIS, EXCESSIVE | REAR YARD - ACCUMULATION OF CHAIRS, FURNITURE, TIRES, HOUSEHOLD ITEMS AND OTHER DEBRIS. | 3529 W MELROSE ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTHEAST CORNER/ DOWNSPOUT - BOTTOM SECTION MISSING. | 3529 W MELROSE ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | EAST ELEVATION/ SERVICE WALK - OBSTRUCTED BY EXTENDED LADDER. | 3529 W MELROSE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1-STORY WOOD PORCH/ COLUMNS - IMBEDDED IN FRACTURED CONCRETE BASES. ENTIRE GRADE TO 1ST FLOOR STAIRWAY IS WEAK AND UNSTABLE; SWAYS. STRINGERS - UPPER ENDS ARE INADEQUATELY FASTENED WITH NAILS ONLY; ROTTED. CONRETE STOOP AT BOTTOM OF STAIRWAY HAS BROKEN AND MISSING CONCRETE. TREADS AND RISERS - ROTTED. ALL RAILINGS - LOOSE, PULLING AND ROTTED; PICKETS SPACED 5 TO 7 INCHES APART. GUARD RAILINGS - ONLY 37 INCHES HIGH. FRONT 2ND FLOOR ROOFTOP DECK - CONSTRUCTED OF 2X4 DECK JOISTS. DECK BOARDS - LOOSE AND WEAK. | 3529 W MELROSE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT METAL SPIRAL STAIRCASE BUILT WITHOUT A PERMIT, NOT SECURELY ATTACHED TO 2ND FLOOR ROOF TOP DECK. ENTIRE STAIRCASE IS LOOSE, WEAK AND UNSTABLE. METAL COLUMN IS RESTING ON SOIL, FOUNDATION STATUS UNKNOWN. PLANS AND PERMIT NOW REQUIRED FOR FRONT METAL SPIRAL STAIRCASE.SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU. | 3529 W MELROSE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT METAL SPIRAL STAIRCASE BUILT WITHOUT A PERMIT, NOT SECURELY ATTACHED TO 2ND FLOOR ROOF TOP DECK. ENTIRE STAIRCASE IS LOOSE, WEAK AND UNSTABLE. METAL COLUMN IS RESTING ON SOIL, FOUNDATION STATUS UNKNOWN. PLANS AND PERMIT NOW REQUIRED FOR FRONT METAL SPIRAL STAIRCASE.SUBJECT TO FIELD INSPECTION AND APPROVAL BY IRON BUREAU. | 3529 W MELROSE ST | COMPLAINT | PASSED | View |
REPAIR DOWNSPOUT | SOUTHEAST CORNER/ DOWNSPOUT - BOTTOM SECTION MISSING. | 3529 W MELROSE ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | EAST ELEVATION/ SERVICE WALK - OBSTRUCTED BY EXTENDED LADDER. | 3529 W MELROSE ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR YARD - ACCUMULATION OF CHAIRS, FURNITURE, TIRES, HOUSEHOLD ITEMS AND OTHER DEBRIS. | 3529 W MELROSE ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT 1-STORY WOOD PORCH/ COLUMNS - IMBEDDED IN FRACTURED CONCRETE BASES. ENTIRE GRADE TO 1ST FLOOR STAIRWAY IS WEAK AND UNSTABLE; SWAYS. STRINGERS - UPPER ENDS ARE INADEQUATELY FASTENED WITH NAILS ONLY; ROTTED. CONRETE STOOP AT BOTTOM OF STAIRWAY HAS BROKEN AND MISSING CONCRETE. TREADS AND RISERS - ROTTED. ALL RAILINGS - LOOSE, PULLING AND ROTTED; PICKETS SPACED 5 TO 7 INCHES APART. GUARD RAILINGS - ONLY 37 INCHES HIGH. FRONT 2ND FLOOR ROOFTOP DECK - CONSTRUCTED OF 2X4 DECK JOISTS. DECK BOARDS - LOOSE AND WEAK. | 3529 W MELROSE ST | COMPLAINT | PASSED | View |