The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN WINDOW SASH | 1357 BASEMENT WINDOW FLAKING PAINT | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | 1355 1/2 STEEL LINTEL AT DOOR DEFECTED RUSTED | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1357 3RD HOLE IN PLASTER REAR STAIRWELL | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY MOST UNITS OWNER ASKED US TO LEAVE | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 3RD FLOOR APARTMENT BATHTUB *1357* | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL SYSTEM III EMERGENCY LIGHTING SYSTEM | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL GFCI IN WEST LOCATIONS (18-27-210.8) | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | REAR STAIRWELLS FLAKING PAINT ON BRICKS | 1351 W TOUHY AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2005 - 2008 | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2005 - 2008-1/25/10- COMPLIED | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | MISSING FIRE EXTINGUISHERS THROUGH OUT. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
PARAPET | WASHED OUT MORTAR | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTHEAST AND NORTHWEST INNER COURT YARD WALLS WASHED OUT MORTAR | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WEST ENCLOSED PORCH AT CEILING-OPEN HOLE MISSING PLASTER -BUBBLED PLASTER. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | 1359 3RD CFLOOR UNIT-NORTH WALL BUBBLED PLASTER, FLAKY PAINT | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | SOUTH AND EAST PORCHES NO ENTRY | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | MISSING FIRE EXTINGUISHERS THROUGH OUT. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
PARAPET | WASHED OUT MORTAR | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTHEAST AND NORTHWEST INNER COURT YARD WALLS WASHED OUT MORTAR | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1359 FRONT INTERIOR STAIRS WATER DAMAGED WALLS AND CEILING.1359 3N WEST ENCLOSED PORCH MISSING PLASTER -BUBBLED PLASTER AND THROUGH OUT APARTMENT WATER DAMAGE . | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | 1359 3RD N FLOOR UNIT-NORTH WALL BUBBLED PLASTER, FLAKY PAINT, AND 1351GARDEN APARTMENT FRONT CLOSET FOYER CLOSET BLACK GROWTH AT BASE OF WALL. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REMOVE STAGNANT WATER BSMT | EXTERIOR NORTH NEAR 1351 STAGNANT WATER AT SERVICE WALK. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 1351 GARDEN APARTMENT MISSING CARBON MONOXIDE DETECTOR. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | 1351 GARDEN APARTMENT KITCHEN SINK BASE WATER DAMAGED AT BASE. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EXTERIOR EAST SERVICE WALK UNEVEN AND BROKEN PAVEMENT CAUSING TRIP HAZARD. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 4 EXTERIOR WOOD 3STORY PORCH SYSTEMS- 1355- FOUNDATION NOT VERIFIRED; COLUMNS 4X6 LAP JOINT UNDERSIZED WITH 3 BOLTS, NEWEL POST 4X4 LAP JOINT NAILED CONNECTION; STAIRS WINDER TYPE, STRINGER TO BRICK CONNECTION UNDER SIZED AND OVER SPACED BOLTS, LEDGER BEAM CONNECTION AND STRINGER CONNECTION TO COLUMN ALL TOENAILED CONNECTION; RAILINGS ALL TOE NAILED CONNECTIONS CUT NAILED TO BRICK, MISSING INTERMEDIATE POST, EXCESSIVE SPACING BETWEEN STAIR TREAD AND BOTTOM OF RAILS; 1353 FOUNDATION NOT VERIFIED; COLUMN 4X6 UNDER SIZED LAP JOINTS WITH 3 BOLTS, 4X4 LAP JOINTS UNDER SIZED AND NAILED; JOIST ORIGINAL POCKETED INTO BRICK WITH SCABB ON EACH SIDE NOT POCKETED, MISSING JOIST HANGERS; RAILINGS ALL TOE NAILED CONNECTION, NAIED TO BRICK, MISSING INTERMEDIATE POST, AND OVER SPACED TREAD TO BOTTOMOF RAIL; OPEN POCKETS AT BRICK WERE STRINGER POCKETS INTO BRICK. 1351 CENTER FOUNDATION NOT VERFIED; COLUMN 4X6 16" LAP JOINT 2 BOLTS, 4X4 LAP JOINT NAILED; JOIST SCABBED AND NOT POCKETED UNLIKE ORIGINAL JOIST AND MISSING JOIST HANGERS; STAIRS WINDER TYPE STRINGER TO BRICK CONNECTION UNDER SIZED BOLTS AND OVER SPACED, STRINGER TO COLUMN CONNECTION TOE NAILED; 1351 FRONT, FOUNDATION NOT VERIFIED; COLUMN 6X6, NEWEL 4X4 12" LAP JOINTS WITH 2 BOLTS, JOIST SCABBED AND NOT POCKETED LIKE ORIGINAL JOIST, MISSING JOIST HANGER; RAILINGS ALL TOENAILED AND NAILED CONNECTIONS, MISSING INTERMEDIATE POST, EXCESSIVE SPACING BETWEEN STAIR TREAD AND BOTTOM OF RAILINGS; STAIRS, STRINGER TO BRICK CONNECTION UNDER SIZED AND OVER SPACED BOLTS AND TOE NAILED CONNECTIONS TO COLUMN AND LEDGER, LOOSE TREAD 1ST TO 2ND LEVEL; PERMIT REQUIRED WITH DETAIL STAMPED PLANS WITH REQIRED REPAIRS. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | PROVIDE EVIDENCE OF BUILDING REGISTRATION FOR YEARS 1990-2004. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, REAR PORCHES, AND SPECIFICALLY UNIT #1357 1/2-1N FOR COMPLAINT OF BUGS. UNVERIFIED DETECTORS AND CONDITIONS. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - INCOMPLETE INFORMATION; ADDRESS MISSING. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH - HANDRAILS MISSING FROM GRADE TO BASEMENT (AT THRU-CORRIDOR) | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EAVES | NORTH - EAVES - PAINT PEELING | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST - LINTELS (AT ENTRY DOORS) - WARPED, RUSTING, WASHED OUT MORTAR AT 2ND AND 4TH ENTRY DOOR. PERMIT REQUIRED TO REPLACE LINTELS. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | WEST - ENTRY DOORS - DEADBOLT LOCKS - MISSING | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | 1351 REAR PORCHES FLAKY PAINT. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH 2 - 3 COURTYARD STAIRWELL 1 AND 2 BROKEN GLASS BLOCK. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH 2 AND 3 SPALLING BRICK. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | 1351 PORCH AT 2 ROTTEN DECK. PORCHES ANCHOR STRINGERS, RAILS 32", 4"X4" COLUMNS, NO JOIST HANGERS, STRINGERS, ROTTEN BOTTOM RAIL, IMPROPER FOUNDATION. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH NO GUARDRAIL . | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMIT AND PLANS TO REPAIR PORCH. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENT AND BASEMENT. | 1351 W TOUHY AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION AT GRADE AT ALLEY-SPALLED BRICKS,WASHED OUT MORTAR,AT DOWNSPOUT. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, REAR PORCHES, AND SPECIFICALLY UNIT #1357W /APT.2N AND 1359W /APT.2N FOR COMPLAINT OF RAT INFESTED. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | REAR ELEVATION AT ALLEY-MISSING DOWNSPOUT SECTION AT GRADE. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | NORTH - CORNICE - BROKEN STONE ABOVE 3RD FLOOR WINDOW AT NW CORNER | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION[GRADE TO BASEMENT] - HANDRAIL MISSING. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EAVES | NORTH ELEVATION /EAVES - PEELING PAINT. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | SOUTH AND EAST PORCHES NO ENTRY | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | PERMIT #100727488 ISSUED 12/8/2017 TO REPLACE 5 OPEN WOOD PORCHES NEVER INSPECTED. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | 1357 1/2 / FIRST FLOOR / WINDOW SCREENS - TORN, TADDERED. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION / AT GRADE OF ALLEY WAY - SPALLED BRICKS,WASHED OUT MORTAR AND MISSING BRICKS. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OR OCCUPANCY. | 1351 W TOUHY AVE | PERIODIC | FAILED | View |