The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 2919 W BELMONT AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION, REAR EXTERIOR STAIR FROM GRADE TO 1ST FLOOR - 4X4 COLUMNS SHIFTING FROM BRICK FOUNDATION. TOP OF STRINGER CRACKED BOTTOM OF STRINGER ROTTING. TREADS AND RISERS CRACKED AND BROKEN. RAILING AT TOP OF LANDING ONLY 34 1/2 INCHES HIGH, MISSING RAILINGS AT STAIR - FALL HAZARD. PLANS AND PERMIT REQUIRE TO REPLACE STAIR STRUCTURE. WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2919 W BELMONT AVE | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | 1ST FLOOR DWELLING UNIT REHAB - NEW DRYWALL AND ELECTRICAL AS SEEN FROM OPEN FRONT DOOR AND SIDE WINDOW. NO PERMITS POSTED. | 2919 W BELMONT AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | BUILDING - 2ND FLOOR NO RESPONSE, 1ST FLOOR, WORKER REFUSED ENTRY THEN CLOSED AND LOCKED DOOR. UNVERIFIED DETECTORS AND 2ND FLOOR CONDITIONS, UNVERIFIED EXTENT OF REHAB AT 1ST FLOOR. | 2919 W BELMONT AVE | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN ATTIC DWELLING UNIT WITHOUT A PERMIT. | 2919 W BELMONT AVE | COMPLAINT | FAILED | View |
ADDITIONAL EXIT | ATTIC DWELLING UNIT - ONLY ONE MEANS OF EGRESS AT REAR ENCLOSED PORCH. MISSING 2ND MEANS OF EGRESS FOR DWELLING UNIT. | 2919 W BELMONT AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FRONT INTERIOR STAIRS AND ATTIC LEVEL AT REAR ENCLOSED PORCH - MISSING SMOKE DETECTORS AT TOP OF EACH STAIRWELL. | 2919 W BELMONT AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION, BASEMENT - BROKEN GLASS BLOCK WINDOW. SOUTH ELEVATION, REAR ENCLOSED PORCH AREA - 1ST AND 2ND FLOOR WINDOWS BOARDED UP. | 2919 W BELMONT AVE | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS IN ATTIC DWELLING UNIT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. ALL WORK SUBJECT TOFIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES PRIOR TO OCCUPANCY. | 2919 W BELMONT AVE | COMPLAINT | FAILED | View |