PIN: 13251030150000
Property Address: 2919 W BELMONT AVE
City - Zip: CHICAGO - 60618
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77150
2023 Tax District: 77135
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED. 2919 W BELMONT AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION, REAR EXTERIOR STAIR FROM GRADE TO 1ST FLOOR - 4X4 COLUMNS SHIFTING FROM BRICK FOUNDATION. TOP OF STRINGER CRACKED BOTTOM OF STRINGER ROTTING. TREADS AND RISERS CRACKED AND BROKEN. RAILING AT TOP OF LANDING ONLY 34 1/2 INCHES HIGH, MISSING RAILINGS AT STAIR - FALL HAZARD. PLANS AND PERMIT REQUIRE TO REPLACE STAIR STRUCTURE. WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. 2919 W BELMONT AVE COMPLAINT CLOSED View
PERMIT REQUIRED - CONTRACTOR 1ST FLOOR DWELLING UNIT REHAB - NEW DRYWALL AND ELECTRICAL AS SEEN FROM OPEN FRONT DOOR AND SIDE WINDOW. NO PERMITS POSTED. 2919 W BELMONT AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION BUILDING - 2ND FLOOR NO RESPONSE, 1ST FLOOR, WORKER REFUSED ENTRY THEN CLOSED AND LOCKED DOOR. UNVERIFIED DETECTORS AND 2ND FLOOR CONDITIONS, UNVERIFIED EXTENT OF REHAB AT 1ST FLOOR. 2919 W BELMONT AVE COMPLAINT CLOSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN ATTIC DWELLING UNIT WITHOUT A PERMIT. 2919 W BELMONT AVE COMPLAINT FAILED View
ADDITIONAL EXIT ATTIC DWELLING UNIT - ONLY ONE MEANS OF EGRESS AT REAR ENCLOSED PORCH. MISSING 2ND MEANS OF EGRESS FOR DWELLING UNIT. 2919 W BELMONT AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2ND FRONT INTERIOR STAIRS AND ATTIC LEVEL AT REAR ENCLOSED PORCH - MISSING SMOKE DETECTORS AT TOP OF EACH STAIRWELL. 2919 W BELMONT AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION, BASEMENT - BROKEN GLASS BLOCK WINDOW. SOUTH ELEVATION, REAR ENCLOSED PORCH AREA - 1ST AND 2ND FLOOR WINDOWS BOARDED UP. 2919 W BELMONT AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS IN ATTIC DWELLING UNIT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. ALL WORK SUBJECT TOFIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES PRIOR TO OCCUPANCY. 2919 W BELMONT AVE COMPLAINT FAILED View