Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
EXPOSED WIRING | FURNACE ROOM (D&H) | 62 W 68TH ST | COMPLAINT | PASSED | View |
DEFECTIVE BREAKER | REMOVE MINI BREAKERS | 62 W 68TH ST | COMPLAINT | PASSED | View |
DEFECTIVE POWER SERVICE | USED THIN WALL FOR SERVICE RISER | 62 W 68TH ST | COMPLAINT | PASSED | View |
NO PERMIT WIRING | NEW SERVICE REHAB | 62 W 68TH ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING | 62 W 68TH ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED | NO PERMIT FOR WOOD FENCE | 62 W 68TH ST | COMPLAINT | FAILED | View |
PARAPET | SOUTH-EAST CORNER PARAPET WALL BUCKLING OUT,EAST WALL BUCKLING IN.[PERMIT FOR REPAIRS] | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | SOUTH EXTERIOR DOOR FRAME; STONE THERSHOLD BROKEN | 62 W 68TH ST | COMPLAINT | FAILED | View |
EXIT THROUGH BEDROOM/BATHROOM | 2ND FLR.REAR BEDROOM; EXIT OUT TO PORCH | 62 W 68TH ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1ST FLR.KITCHEN DOOR AND BASEMENT EXTERIOR DOOR; AIR-SEEPAGE [OPEN GAPS] | 62 W 68TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS AND PERMITS TO REHAB BUILDING,ALTER 2# DWELLING UNITS INTO 1# DWELLING UNIT | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | CYCLONE FENCE; BENT AND LOOSE | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT EXTERIOR STAIR; HAND RAIL MISSING | 62 W 68TH ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | OWNER HAS ILLEGAL GAS HOOK UP,USING FLEX HOSE OFF MAIN GAS LINE AND BYPASS GAS METER. | 62 W 68TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - MISSING OWNER'S I.D. SIGN. | 62 W 68TH ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAPPING. | 62 W 68TH ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SOUTHEAST CORNER - 6 FEET WOODEN FENCE INSTALLED WITHOUT A PERMIT. | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR YARD - CYCLONE FENCE BROKEN AND LEANING, WITH TOP RAILS MISSING. | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1ST FLOOR WOODEN STAIR - 4X4 COLUMNS ERECTED ON CONCRETE BLOCKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. 2X8 DECK JOISTS ONLY TOE-NAILED TO RIM BEAMS. REAR BASEMENT TO GRADE CONCRETE STAIRWAY - MISSING HANDRAIL. NO PERMIT REQUIRED FOR REPAIRS. | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-STORY / REAR PORCH SYSTEM - 6X6 COLUMNS ERECTED ON SERVICE WALKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X8 DECK JOISTS SPAN 22 FEET. 6X6 BEAMS PULLING AWAY FROM OVER-NOTCHED COLUMNS. RIM BEAMS ONLY TOE-NAILED TO COLUMNS. COLUMN SPLICE CONNECTIONS ONLY NAILED. GUARDRAIL HEIGHT ONLY 32 INCHES. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 62 W 68TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING: ENTRY REFUSED BY THE CALLER - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT LAUNDRY ROOM WALL; DRYWAL HAS MOLD | 62 W 68TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT INTERIOR STAIR BOTTOM RISER; IMPROPER HEIGHT | 62 W 68TH ST | COMPLAINT | FAILED | View |
REMOVE AND REPLACE***** | OUTLET IN BASEMENT KITCHEN WITH GFCI 18-27-2210.8 | 62 W 68TH ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | SOUTH PORCH; TREADS BROKEN,4X4 OUT OF PLUMB,NO FOOTING,REPLACE 4X4S WITH 6X6S. NORTH PORCH; LEDGER BOARDS PULLING AWAY FROM THE WALL,STRINGER WOOD SPLIT AND OVER NOTCH,GUARD RAILS UNDER SIZE AND LOOSE,2X6 ROOF AND DECK JOIST,UPRIGHTS LAP JOINTS TOE NAIL AND OVER NOTCH CUTS,BRACKETS MISSING AT CONNECTIONS,6X6 UPRIGHTS SEVERE STRESS CRACKS,1ST TO 2ND FLR.INSUFFICIENT HEAD ROOM.[SUBMIT PLANS AND PERMITS FOR REPAIRS] | 62 W 68TH ST | COMPLAINT | FAILED | View |
REMOVE************** | ROMEX IN FURNACE ROOM 18-27-336.3 | 62 W 68TH ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | CHIMNEY CAPPING; MISSING | 62 W 68TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | SEE NOTICE #11677 | 62 W 68TH ST | PERMIT | PASSED | View |
COVER OUTLETS AND JBS | BASEMENT REAR WALL; WALL OUTLET NO COVER PLATE | 62 W 68TH ST | COMPLAINT | FAILED | View |