Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /ALL APTS. ¿ NO RESPONSE. UNABLE TO VERIFY DETECTORS, AND CONDITIONS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO 2ND AND 3RD FLOOR (INTERIOR) | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2008,2009 | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT STAIR NO RISER, TREADS SPLIT AND WEAK. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | ENCLOSE PORCH NO SMOKE DETECTOR | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT CEILING DRYWALL DAMAGE, INTERIOR WALL MORTAR MISSING, 1ST FLOOR MIDDLE AREAWAY WALL DRYWALL BROKEN. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSE PORCH TREADS, LANDING WOOD WORN OUT G TO 2ND FL. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 1ST FLOOR REAR FLOOR ROTTED, BATHROOM FLOOR WEAK | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER I.D SIGN INCOMPLETE(MISSING ADDRESS). | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
RESET LOOSE FIXTURE | 1ST FLOOR BATHROOM TOILET LOOSE | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | 1ST FLOOR CEILING JUNCTION BOX EXPOSED WIRING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO INTERIOR | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO INTERIOR TO VERIFY OCCUPANCY,DETECTORS,PORCHES AND OVERALL CONDITION FOR 2016 ANNUAL INSPECTION. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO INTERIOR TO VERIFY OCCUPANCY,DETECTORS,PORCHES AND OVERALL CONDITION FOR 2016 ANNUAL INSPECTION. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | BUILDING THROUGHOUT /PEEPHOLE DEVICES ON ALL DWELLING UNIT DOORS - MISSING. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT / CARTBON MONOXIDE DETECTOR - MISSING. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 2ND AND 3RD FLOORS / FIRE EXTINGUISHER TAGS - EXPIRED (2005). | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 200 TO 2006. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION STONE CHIMNEY CAP HAS WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
CHIMNEY | NORTH ELEVATION FROM GRADE TO TOP CHIMNEY HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EAST EXTERIOR DOOR WOOD SPLIT | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED AND SPLIT | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH EXTERIOR WALL MORTAR MISSING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | IMPROPER SUPPORT, 1ST FLOOR MIDDLE AREAWAY FLOOR SAGGING. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT STAIR NO RISER, TREADS SPLIT AND WEAK. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT CEILING DRYWALL DAMAGE, INTERIOR WALL MORTAR MISSING, 1ST FLOOR MIDDLE AREAWAY WALL DRYWALL BROKEN. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | 1ST FLOOR CEILING JUNCTION BOX EXPOSED WIRING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | ENCLOSE PORCH NO SMOKE DETECTOR | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 200 TO 2006. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EAST EXTERIOR DOOR WOOD SPLIT | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR REPAIRS FLOORING, FLOOR JOIST AND REHAB 1ST FLOOR WEST SECTION OF BUILDING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR COPING | SOUTH COPING TILES MISSING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH EXTERIOR WALL MORTAR MISSING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION STONE CHIMNEY CAP HAS WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND NORTH ELEVATION FROM GRADE TO ROOF IN VARIOUS LOCATIONS MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
CHIMNEY | NORTH ELEVATION FROM GRADE TO TOP CHIMNEY HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER I.D SIGN INCOMPLETE(MISSING ADDRESS). | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2008 THRU 2016. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND NORTH ELEVATION FROM GRADE TO ROOF IN VARIOUS LOCATIONS MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER I.D SIGN INCOMPLETE(MISSING ADDRESS). | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /ALL APTS. ¿ NO RESPONSE. UNABLE TO VERIFY DETECTORS, AND CONDITIONS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
RELOCATE SMOKE DETECTOR | FRONT INTERIOR STAIRWELL /RELOCATE SMOKE DETECTORS LOCATED ABOVE DOOR HEADERS. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY ENCLOSED PORCH / 4X4 COLUMN ERRECTED ON PLYWOOD SUBFLOOR, UNABLE TO DETERMIN IF JOST SYSTEM BELOW CAN SUPPORT COLUMN. 2X8 JOISTS SPAN UP TO 12 FEET 5 INCHES. SOME JOISTS ARE TWISTING. STAIR STRINGERS FASTENED WITH NAILS ONLY. STAIR RISERS MEASURE 8 1/2 INCHES. GUARD RAILS FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPAIR ENCLOSED PORCH. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO 2ND AND 3RD FLOOR (INTERIOR) | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2008,2009 | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2008 THRU 2016. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | MAIN BUILDING TO ATTACHED GARAGE /BASEMENT AND 1ST. FL. DOORS - FIRE RATED TAG - MISSING.2ND. AND 3RD. FL. /MECHANICAL ROOMS - DOORS MISSING. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT THROUGHOUT /SMOKE DETECTORS - MISSING. | 8928 S COMMERCIAL AVE | PERIODIC | FAILED | View |