Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 2:41 PM
PIN: 20111000460000
Property Address: 4742 S DREXEL BLVD
City - Zip: CHICAGO - 60615
2023 Property Class: 915
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
UNINTERRUPTED EXIT AT GRADE THE GANGWAY AT THE SOUTH ELEVATION HAS A CHAINED / PADLOCKED GATE AT THE ALLEY. THIS IS A VERY NARROW GANGWAY WITH 3-3 STORY PORCHES EGRESSING INTO THIS GANGWAY (9 APARTMENTS USE THESE PORCHES). IN THE EVENT OF A FIRE, THERE IS NO EGRESS TO THE ALLEY. UNSAFE CONDITION. 4742 S DREXEL BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY IN ORDER TO CONDUCT ANNUAL INSPECTION. 4742 S DREXEL BLVD PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING FRONT INTERIOR STAIRWAY AT 4744-1/2 S./, 3RD FLOOR CEILING - DRYWALL HAS A HOLE.BASEMENT BICYCLE ROOM AND 4748 S./ BASEMENT STORAGE ROOM, CEILINGS - PLASTER HAS HOLES. 4742 S DREXEL BLVD COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS EAST ELEVATION - MISSING WINDOW SCREENS. 4742 S DREXEL BLVD COMPLAINT FAILED View
REPAIR EXTERIOR WALL WEST AND NORTH ELEVATIONS - WASHED OUT MORTAR AT GRADE. 4742 S DREXEL BLVD COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH EXTERIOR STAIRS - MISSING HANDRAILS. 4742 S DREXEL BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM 7 WOOD PORCHES ALL DEFICIENCIES SAME - (1) COLUMNS TWISTING (2) STRINGERS NAILED, POPING OUT (3) GUARDRAILS AND HANDRAILS NAILED TO COLUMNS AND BUILDING STRUCTURE NOT SECURE (4) PORCH STAIR WINDERS NOT PROPERLY CONNECTED NAILED, NAILS RUSTING, POPING OUT, SOME NAILS ARE NOT PROPERLY SECURE TO TREADS OR RISERS OR TO COLUMNS, TREADS AND RISERS SITTING UPON ONE ANOTHER FOR SUPPORT AT COLUMN CONNECTION INSUFFICIENT WEAK CONNECTION (5) PLANS AND PERMITS FOR ALL REPAIRS 4742 S DREXEL BLVD COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO ENTRY, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS 4742 S DREXEL BLVD COMPLAINT PASSED View