The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CUT OR REMOVE HIGH WEEDS | OVERGROWN. 2' HIGH. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | COLUMNS SET ON CONCRETE - FOUNDATION STATUS UNKNOWN. LEDGER BEAM ATTACHED TO EXTERIOR WALL WITH NAILS ONLY. 2" X 6" DECK JOIISTS SPAN 12". DECK JOISTS ATTACHED TO RIM JOISTS WITH NAILS ONLY. STRINGERS ATTACHED TO RIM JOISTS AND DECK JOISTS WITH NAILS ONLY. RAIL SECTIONS ARE ONLY36" HIGH. RAIL ROTTEN AND LOOSE. DECKING ROTTEN. NO PERMIT REQUIRED. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CONCRETE CRACKED. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | 2ND APT / FURNACE - OUT SERVICE .2ND FL NO ELCT IN APT . PER SECTION CODE (14X-3-305.1, 14X-8-804.1 THRU 14X-8-804.5 AND 14X-8-804.8) . | 8057 S COLES AVE | COMPLAINT | PASSED | View |
HEAT UNIT ADEQUATELY | 2ND FL APT TEMP AT 1142AM 1ST BED RM 64 2ND BED RM 65 DEGRESS PER SECTION CODE (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) | 8057 S COLES AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / SIDING - LOOSE AND BULGING. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 2ND FL APT / STOVE USED AS HEATER . PER SECTION CODE(. (14X-8-802.2) | 8057 S COLES AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY UNVERIFIED DETECTORS AND CONDITIONS. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | OVERGROWN. 2' HIGH. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY UNVERIFIED DETECTORS AND CONDITIONS. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | COLUMN SET ON SOIL - NO FOUNDATION. 4" X 4" COLUMNS RISE TO HEIGHT OF 14'. LEDGER BEAM ATTACHED TO EXTERIOR WALL WITH NAILS ONLY. STRINGERS ATTACHED LEDGER BEAM, COLUMNS, POSTS, RIM JOISTS WITH NAILS ONLY. RIM JOISTS ATTACHED TO COLUMNS AND POSTS WITH NAILS ONLY. DECK JOISTS ATTACHED TO RIM JOISTS WITH NAILS ONLY. RAILS ATTACHED TO EXTERIOR WALL, COLUMNS AND POSTS WITH NAILS ONLY.TREADS ARE ONLY 9" DEEP. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER | SECTION MISSING. OBSTRUCTED. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 8057 S COLES AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH AND APT 2 / SMOKE DETECTORS - MISSING. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | SOUTH ELEVATION / ELECTRIC METER - MISSING. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / 1 STORY WOOD PORCH / STEEL LALLY COLUMNS ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. 2X6 JOISTS - ROTTING AND DETERIORATED. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. STRINGERS - SPACED UP TO 6 FEET APART. GUARDRAILS - SPAN UP TO 9 FEET APART. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. SOUTH ELEVATION / 2 STORY WOOD PORCH / COMBUSTIBLE PORCH HAS BEEN BUILT APROX 12 INCHES AWAY FROM SOUTH NEIGHBOR. 1 COLUMN IS TOUCHING NEIGHBORING GUTTER. COLUMNS ERECTED ON CONCRETE SLAB AND DIRT. FOUNDATION STATUS - UNKNOWN. COLUMNS - TWISITING AT UPPER CONNECTIONS. LEDGER BOARD - MISSING ANCHOR BOLTS. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. REAR ENCLOSED WOOD PORCH / BEAM AT 1ST FLOOR HAS BEEN NOTCHED OUT FOR HEADROOM. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | REAR ENCLOSE PORCH / LIGHTS - OUT OF SERVICE AT TIME OF INSPECTION. | 8057 S COLES AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FL APT / SMOKE DETECTOR - MISSING . PER SECTION CODE (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THRU 14B-9-907.2.10.7, 14B-9-915.4.4 AND 14R-11-1104) | 8057 S COLES AVE | COMPLAINT | PASSED | View |