Chicago Building Violations Data: 84 Violations
Violation Inspector Comments Address Category Status View
STOP LEAKING WATER STOP WATER LEAKING INTO 7320 IW BATHROOM 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7320 COLUMNS UNDERSIZED, SPLICE JOINTS, REQUIRE 5 BOLTS JOISTS OVERSPANNED GUARDEAILS LESS THAN 42" WITH WEAK CONNECTIONS STRINGERS UNDERSIZED AND WEAK, NO BOLTED CONNECTIONS 7324 NO TIE STRAPS AT BEAM TO MASONRY WALL DEFICIENT BEAM TO COLUMN CONNECTION STRINGER UNDERSIZED WITH WEAK CONNECTIONS, GUARDRAILS TOO LOW WITH LOOSE CONNECTIONS MISSING ALL NECESSARY HARDWARE SUCH AS BOLTS, BRACKETS AND JOIST HANGERS 42" FOUNDATIONS REQUIRED 7322 STRINGERS UNDERSIZED WINDERS WEAK NO BOLTED CONNECT 42" FOUNDATIONS REQUIRED LEDGER ATTACHED WITH CUT NAILS GUARDRAILS TOO LOW NO JOIST HANGERS OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE THREE PORCH SYSTEMS 7320 S PHILLIPS AVE PERIODIC FAILED View
FILE BLDG REGISTRATION FILE REGISTRATION WITH DEPT OF BUILDINGS 7320 S PHILLIPS AVE PERIODIC FAILED View
PROVIDE DEADLOCK FOR ENTRANCE PROVIDE DEADLOCK FOR ALL MAIN ENTRY DOORS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET REAR DOOR ROTTED, FRAME DAMAGED 7320 1W 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS DETECTOR OUT OF SERVICE BEEPING ALL INTERIOR STAIRWELLS 7320 S PHILLIPS AVE PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER BATHROOM WALLS WATER DAMAGED 7320 1W 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7320 COLUMNS UNDERSIZED, SPLICE JOINTS, REQUIRE 5 BOLTS JOISTS OVERSPANNED GUARDEAILS LESS THAN 42" WITH WEAK CONNECTIONS STRINGERS UNDERSIZED AND WEAK, NO BOLTED CONNECTIONS 7324 NO TIE STRAPS AT BEAM TO MASONRY WALL DEFICIENT BEAM TO COLUMN CONNECTION STRINGER UNDERSIZED WITH WEAK CONNECTIONS, GUARDRAILS TOO LOW WITH LOOSE CONNECTIONS MISSING ALL NECESSARY HARDWARE SUCH AS BOLTS, BRACKETS AND JOIST HANGERS 42" FOUNDATIONS REQUIRED 7322 STRINGERS UNDERSIZED WINDERS WEAK NO BOLTED CONNECT 42" FOUNDATIONS REQUIRED LEDGER ATTACHED WITH CUT NAILS GUARDRAILS TOO LOW NO JOIST HANGERS OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE THREE PORCH SYSTEMS 7320 S PHILLIPS AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION SR#07-02406023-UNABLE TO DO THOROUGH INSPECTION OF REAR PORCHES. VISIBLE FROM ALLEY AND ADJACENT PROPERTY ONLY, ALSO COULD NOT VERIFY INTERIOR CONDITIONS OR DETECTORS. COULD NOT VERIFY COMPLAINT OF INADEQUATE DOOR LOCKS AT 7324 S. 7320 S PHILLIPS AVE PERIODIC FAILED View
SYSTEM III RESTORE DEFECTIVE AND INOPERABLE BATTERY UNITS, 7320 STAIR CASE AT GROUND,1ST-3RD FLOORS,7322 STAIR CASE AT 1ST-3RD FLOORS,7324 STAIR CASE AT 2ND FLOOR, A PERMIT WILL BE REQUIRED TO CORRECT VIOLATION 7320 S PHILLIPS AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR REAR SCREEN/SECURITY DOORS AT MOST APARTMENTS DOUBLED KEYED LOCKS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7320 S/REAR PORCH COLUMNS ERECTED ON CONCRETE PAVEMENT, STRINGER SEPERATING FROM MASONARY WALLS, 3RD FLOOR RAILS WEAK BEAMS POCKETED INTO WALLS OVER DOOR AND WINDOW OPENINGS, 7322 S/COLUMNS ERECTED ON PAVEMENT, OVERSPANNED 2X8 JOISTS SPAN 10' FOOT, 4X4 COLUMNS OVER 12'FOOT ARE UNDERSIZED, STAIR TRENDS WEAK STRINGERS OVER NOTCHED LEANING 3 1/2" INCHES OF MATERIAL AT WINDERS. 7324 S/COLUMNS ERECTED ON PAVEMENT, UNDERSIZED 4X4 COLUMNS OVER 12' FOOT LING, STRINGERS OVERNOTCHED LEANING 3 1/2" OF MATERIAL AT WINDERS, 6 FOOT 6" INCHES HEADROOM AT GRADE TO 1ST FLOOR LEVEL STAIRS SPANNING 12' FOOT ARE UNDERSIZED, SUBMIT PLANS AND OBTAIN A PERMIT FOR REPAIRS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION OPEN STORE SILLS ALL LEVELS. 7320 S PHILLIPS AVE PERIODIC FAILED View
MICE/RODENTS MICE 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7320 S/REAR PORCH COLUMNS ERECTED ON CONCRETE PAVEMENT, STRINGER SEPERATING FROM MASONARY WALLS, 3RD FLOOR RAILS WEAK BEAMS POCKETED INTO WALLS OVER DOOR AND WINDOW OPENINGS, 7322 S/COLUMNS ERECTED ON PAVEMENT, OVERSPANNED 2X8 JOISTS SPAN 10' FOOT, 4X4 COLUMNS OVER 12'FOOT ARE UNDERSIZED, STAIR TRENDS WEAK STRINGERS OVER NOTCHED LEANING 3 1/2" INCHES OF MATERIAL AT WINDERS. 7324 S/COLUMNS ERECTED ON PAVEMENT, UNDERSIZED 4X4 COLUMNS OVER 12' FOOT LING, STRINGERS OVERNOTCHED LEANING 3 1/2" OF MATERIAL AT WINDERS, 6 FOOT 6" INCHES HEADROOM AT GRADE TO 1ST FLOOR LEVEL STAIRS SPANNING 12' FOOT ARE UNDERSIZED, SUBMIT PLANS AND OBTAIN A PERMIT FOR REPAIRS1.-SUBMIT THE INSPECTOR SIGNED PERMIT ACCEPTING THE REPAIRS AND UPGRADES OF SYSTEMS UNDER PERMIT #100291100. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION OPEN STORE SILLS ALL LEVELS. 7320 S PHILLIPS AVE PERIODIC FAILED View
PROVIDE DEADLOCK FOR ENTRANCE PROVIDE DEADLOCK FOR ALL MAIN ENTRY DOORS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET REAR DOOR ROTTED, FRAME DAMAGED 7320 1W 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS DETECTOR OUT OF SERVICE BEEPING ALL INTERIOR STAIRWELLS 7320 S PHILLIPS AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR REAR SCREEN/SECURITY DOORS AT MOST APARTMENTS DOUBLED KEYED LOCKS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION OPEN STONE SILLS ALL LEVELS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET 7320 STAIRWELL ENTRY DOOR AT GRADE WITH GAPS AROUND FRAME, MISSING SILL, OPEN WALL JOINTS. OTHER ENTRY OPENINGS WITH SIMILAR DEFECTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
PROVIDE DEADLOCK FOR ENTRANCE PROVIDE DEADLOCK FOR ALL MAIN ENTRY DOORS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS DETECTOR OUT OF SERVICE BEEPING ALL INTERIOR STAIRWELLS 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7320 S/REAR PORCH COLUMNS ERECTED ON CONCRETE PAVEMENT, STRINGER SEPERATING FROM MASONARY WALLS, 3RD FLOOR RAILS WEAK BEAMS POCKETED INTO WALLS OVER DOOR AND WINDOW OPENINGS, 7322 S/COLUMNS ERECTED ON PAVEMENT, OVERSPANNED 2X8 JOISTS SPAN 10' FOOT, 4X4 COLUMNS OVER 12'FOOT ARE UNDERSIZED, STAIR TRENDS WEAK STRINGERS OVER NOTCHED LEANING 3 1/2" INCHES OF MATERIAL AT WINDERS. 7324 S/COLUMNS ERECTED ON PAVEMENT, UNDERSIZED 4X4 COLUMNS OVER 12' FOOT LING, STRINGERS OVERNOTCHED LEANING 3 1/2" OF MATERIAL AT WINDERS, 6 FOOT 6" INCHES HEADROOM AT GRADE TO 1ST FLOOR LEVEL STAIRS SPANNING 12' FOOT ARE UNDERSIZED, SUBMIT PLANS AND OBTAIN A PERMIT FOR REPAIRS1.-SUBMIT THE INSPECTOR SIGNED PERMIT ACCEPTING THE REPAIRS AND UPGRADES OF SYSTEMS UNDER PERMIT #100291100. 7320 S PHILLIPS AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR REAR SCREEN/SECURITY DOORS AT MOST APARTMENTS DOUBLED KEYED LOCKS 7320 S PHILLIPS AVE PERIODIC FAILED View
NO POSTED ADDRESS DOOR AT 7324 MISSING NUMBER. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSTALL DEAD BOLT LOCK AT 7322 BOTH DOOR MISSING DEADBOLT LOCKS. 7320 S PHILLIPS AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS ALL LEVEL ONE OF TWO WINDOWS SCREENS MISSING. 7320 S PHILLIPS AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION PART OF BUILDING -7320 AND 7322-NO ENTRY, UNABLE VERIFY COMPLAINT OF ROOF LEAKING AND ROTTED FLOOR APT. 3E 7320, ROACHES AND MICE APT. 1E 7322. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR CORNICE SOUTH CORNICE; BROKEN STONE AND OPEN JOINTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION NORTHEAST CORNER - STONE CORNER OPEN MORTAR JOINTS. SOUTH ELEVATION, PARAPET ABOVE 7322 ENTRY - STONE WITH OPEN JOINTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 7324 INTERIOR STAIR - SMOKE DETECTOR AT TOP OF STAIR NOT WORKING. 7324-3N UNIT - SMOKE DETECTOR NOT WORKING. 7320 GROUND FLOOR - MAINTENANCE STORAGE ROOM - SMOKE DETECTOR BEEPING.7320 INTERIOR STAIRS - SMOKE DETECTOR AT TOP OF STAIRWELL NOT WORKING. 7320 UNIT 3W - SMOKE DETECTOR NOT WORKING. 7320 S PHILLIPS AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID 7324-UNIT 3N - CARBON MONOXIDE DETECTOR NOT WORKING. 7320 UNIT 3W - CARBON MONOXIDE DETECTOR NOT WORKING.7320 1-W, NO CARBON MONOXIDE. 7320 S PHILLIPS AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR 7324-3N UNIT - REAR SCREEN DOOR LOCKED, KEY REQUIRED TO EXIT. TENANT DOES NOT HAVE KEY TO OPEN DOOR. 7320 S PHILLIPS AVE PERIODIC FAILED View
MICE/RODENTS BUILDING MICE INFESTED. 7320 S PHILLIPS AVE PERIODIC FAILED View
1HR PUB.CORRIDOR IN MULT. D.U. 7320 GROUND FLOOR - MAINTENANCE STORAGE ROOM AT ENTRY LOBBY MISSING DOOR. PROVIDE PROPER FIRE DOOR TO MAINTAIN CORRIDOR SEPARATION. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSECTS 7320 - UNITS 3E, 3W AND 2E - BEDBUG INFESTATION THROUGHOUT. - PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BEDBUGS THROUGHOUT, BY EMPLOYING AND EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATIONS. 7320 S PHILLIPS AVE PERIODIC FAILED View
ABANDONED REFRIGERATOR 7322 PORCH AREA; ABANDON REFRIGERATOR. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH EXTERIOR WALL; MORTAR MISSING 7320 S PHILLIPS AVE PERIODIC FAILED View
CHIMNEY CHIMNEY; MORTAR MISSING. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR WINDOW SILLS NORTH AND WEST WINDOW SILLS; OPEN JOINTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS BUILDING WINDOW SCREENS; TORN OR MISSING. 7320 S PHILLIPS AVE PERIODIC FAILED View
FLAKY INTERIOR PAINT BUILDING REAR EXTERIOR DOORS AND FRAMES; FLAKY PAINT. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR DOOR, INT. 7320 1-W, APARTMENT DOOR; BROKEN.7324 2-N, APARTMENT DOOR; BROKEN. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 7320 1-W, BATHROOM CEILING; BUCKLING.7320 3-E, BEDROOM CEILING; WATER DAMAGE.7322 INTERIOR STAIR WALLS; UNFINISH REPAIR WORK.7322 2-W, BEDROOM CEILING; WATER DAMAGE.7324 2-S, BATHROOM WALL; WATER DAMAGE.7324 2-N LIVING ROOM CEILING; WATER DAMAGE. 7320 S PHILLIPS AVE PERIODIC FAILED View
KEEP FIXTUR CLEAN AND SANITARY 7320 3-E, BATHROOM TUB; UNSANITARY CONDITION.7324 3-E, BATHROOM TUB; PAINT CHIPS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR DOOR HARDWARE 7320 3-E, BEDROOM DOOR KNOB; MISSING. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR DOOR FRAME, MULLION 7320 3-E, APARTMENT DOOR FRAME; BROKEN.7322 2-W, BATHROOM DOOR FRAME; BROKEN.7324 2-N, APARTMENT DOOR FRAME; BROKEN. 7320 S PHILLIPS AVE PERIODIC FAILED View
CARPETING 7320, 7322 AND 7324 INTERIOR STAIR CARPET; UNSANITARY CONDITION AND TORN. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 7320 INTERIOR STAIR; LANDING AND TREADS LOOSE AND BROKEN.7322 INTERIOR STAIR; TREADS LOOSE. 7320 S PHILLIPS AVE PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER 7322 2-W, BEDROOM CEILING; BROKEN PLASTER.7324 INTERIOR STAIR CEILING; BROKEN PLASTER AND HOLE IN CEILING.7324 2-S, BEDROOM AND LIVING CEILING; BUCKLING PLASTER.7324 2-N, LIVING ROOM CEILING; BUCKLING PLASTER. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 7322 2-W, BEDROOM WINDOW PANE; BROKEN. 7320 S PHILLIPS AVE PERIODIC FAILED View
STOP LEAKING WATER 7322 2-W, BEDROOM CEILING; LEAKS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR ROOF 7324 INTERIOR STAIR ROOF; LEAKS. 7320 S PHILLIPS AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR NO ENTRY INTO ALL FRONT STAIRWAYS, APARTMENTS OR BASEMENT TO VERIFY EGRESS, CARBON MONOXIDE DETECTORS, SMOKE DETECTORS, INTERIOR STRUCTURAL, COSMETIC OR ENVIRONMENTAL CONDITIONS 7320 S PHILLIPS AVE PERIODIC FAILED View
RESTORE EXIT AND EM 7320 S. FRONT STAIRWAY - GROUND AND FIRST FLOOR EMERGENCY LIGHTS NOT WORKING WHEN TESTED 7320 S PHILLIPS AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION EAST END PARAPET - MINOR WASHED OUT BRICK MORTAR JOINTS 7320 S PHILLIPS AVE PERIODIC FAILED View
CHIMNEY NORTH CHIMNEY BELOW CAP - MINOR WASHED OUT BRICK MORTAR JOINTS 7320 S PHILLIPS AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR OF BUILDING 7320 S PHILLIPS AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS MISSING WINDOW SCREENS 7320 S PHILLIPS AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 7322- WOOD DOOR HAS PEELING/SPLIT VENEER AND INTERIOR CASING IS BROKEN 7320 S PHILLIPS AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE 7320- ENTRY DOOR MISSING HANDLE 7320 S PHILLIPS AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS INTERIOR STAIRS-SMOKE DETECTOR,LOW BATTERY. 7320 S PHILLIPS AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY APARTMENT ENTRY DOORS-BURGLAR GATES. 7320 S PHILLIPS AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF UNITS NO RESPONSE,UNVERIFIED DETECTORS AND COMPLAINT OF 3E,BED BUGS. 7320 S PHILLIPS AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS ALL LEVEL ONE OF TWO WINDOWS SCREENS MISSING. 7320 S PHILLIPS AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION PART OF BUILDING -7320 AND 7322-NO ENTRY, UNABLE VERIFY COMPLAINT OF ROOF LEAKING AND ROTTED FLOOR APT. 3E 7320, ROACHES AND MICE APT. 1E 7322. 7320 S PHILLIPS AVE PERIODIC FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED FOR 7320 AND 7324 ENTRY DOORS. 7320 S PHILLIPS AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION NORTHEAST CORNER - STONE CORNER OPEN MORTAR JOINTS. SOUTH ELEVATION, PARAPET ABOVE 7322 ENTRY - STONE WITH OPEN JOINTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR CORNICE SOUTH ELEVATION CORNICE AT PARAPET - OPEN MORTAR JOINTS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 7324 INTERIOR STAIR - SMOKE DETECTOR AT TOP OF STAIR NOT WORKING. 7324-3N UNIT - SMOKE DETECTOR NOT WORKING. 7320 GROUND FLOOR - MAINTENANCE STORAGE ROOM - SMOKE DETECTOR BEEPING.7320 INTERIOR STAIRS - SMOKE DETECTOR AT TOP OF STAIRWELL NOT WORKING. 7320 UNIT 3W - SMOKE DETECTOR NOT WORKING. 7320 S PHILLIPS AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID 7324-UNIT 3N - CARBON MONOXIDE DETECTOR NOT WORKING. 7320 UNIT 3W - CARBON MONOXIDE DETECTOR NOT WORKING. 7320 S PHILLIPS AVE PERIODIC FAILED View
NO KEY TO USE EXIT DOOR 7324-3N UNIT - REAR SCREEN DOOR LOCKED, KEY REQUIRED TO EXIT. TENANT DOES NOT HAVE KEY TO OPEN DOOR. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE 7324 UNITS 1S, 2N AND 2S - MISSING PEEP HOLES IN UNIT ENTRY DOORS. 7320 S PHILLIPS AVE PERIODIC FAILED View
MICE/RODENTS 7324 UNIT 1S - MICE HOLES IN DWELLING UNIT. 7320 S PHILLIPS AVE PERIODIC FAILED View
1HR PUB.CORRIDOR IN MULT. D.U. 7320 GROUND FLOOR - MAINTENANCE STORAGE ROOM AT ENTRY LOBBY MISSING DOOR. PROVIDE PROPER FIRE DOOR TO MAINTAIN CORRIDOR SEPARATION. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 7320 UNIT 3E - WATER DAMAGE AND HOLE SOUTH BEDROOM CLOSET CEILING. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSECTS 7320 - UNITS 3E, 3W AND 2E - BEDBUG INFESTATION THROUGHOUT. - PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BEDBUGS THROUGHOUT, BY EMPLOYING AND EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATIONS. 7320 S PHILLIPS AVE PERIODIC FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED FOR 7320 AND 7324 ENTRY DOORS. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE 7324 UNITS 1S, 2N AND 2S - MISSING PEEP HOLES IN UNIT ENTRY DOORS. 7320 S PHILLIPS AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 7320 UNIT 3E - WATER DAMAGE AND HOLE SOUTH BEDROOM CLOSET CEILING. 7320 S PHILLIPS AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS 7320 1-W AND 7322 2-E; NO SMOKE DETECTORS. 7320 S PHILLIPS AVE PERIODIC FAILED View
ROACHES BUILDING ROACH INFESTED. 7320 S PHILLIPS AVE PERIODIC FAILED View