Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | HOUSE/1ST FLOOR AND 2ND FLOOR/ ROOM TEMPERATURE 33 DEGREES F. AT 12:35 PM.HEATING SYSTEM IS OFF AT TIME OF INSPECTION.GAS SERVICE IS SHUT OFF. NO HEAT PROVIDED. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | HOUSE 1ST FLOOR / GAS SERVICE IS SHUT OFF, NO HOT WATER PROVIDED. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | BASMENT OF HOUSE./ FURNACES APPEAR BROKEN WITH PARTS EXPOSED. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT, 1ST AND 2ND FLOORS - MISSING SMOKE DETECTORS. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST FLOOR - MISSING CARBON MONOXIDE DETECTORS. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT, 1ST AND 2ND FLOORS - MISSING SMOKE DETECTORS. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST FLOOR - MISSING CARBOM MONOXIDE DETECTORS. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR BALCONY | REAR ELEVATION/ ROOF TOP BALCONY / MISSING GUARD RAILINGS. ROTTED WOOD FRAMING MEMBERS. (SEEN FROM REAR YARD). | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 1-STORY ENCLOSED PORCH/ BEAMS ARE ONLY NAILED TO COLUMNS. 2X6 DECK JOISTS - ROTTED AND ONLY NAILED TO HEADER JOISTS. STRINGERS - UPPER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. 1ST FLOOR RAILING SECTION - BROKEN, LOOSE AND ONLY 18 INCHES HIGH. GRADE TO 1ST FLOOR STAIR RAILING - LOOSE, PULLING AND MISSING PICKETS. (UNABLE TO INSPECT SOME FRAMING MEMBERS).PLANS AND PERMITS REQUIRED FOR REAR PORCH REPAIRS. FRONT 1-STORY WOOD PORCH/ MASONRY COLUMNS - LEANING OUT OF PLUMB. UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET AND ARE ONLY NAILED TO RIM JOISTS. LEDGER BEAM - ONLY NAILED TO COLUMNS. STINGERS - UPPER END ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED FOR FRONT PORCH REPAIRS. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR PARTITIONS BUILT IN BASEMENT FORMING 6 ROOMS AND FOR BEDROOM BUILT ON REAR ENCLOSED PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT OF BUILDING / EXTERIOR DOOR / BURGLAR GATE - AT 1ST FL | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / SIDING SECTION - 2NF MISSING. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT OF BUILDING / PORCH GRADE TO 1ST FL LEDGER BOARD NAILED TO WALL .2X6 JOIST NAILED TO HEADERS.2X6 JOIST SPAN 12FT .GUARD RAILS AND STRINGERS NAILED TO COLUMNS ,HEADERS AND WALL.PICKTES LOOSE . PERMIT REQUIRED FOR REPAIRS TO FRONT PORCH. JOIST HANGERS RUSTED. GUARD RAILS AND STRINGERS NAILED ONLY TO COLUMNS, HEADERS AND WALL . | 6128 S BISHOP ST | COMPLAINT | CLOSED | View |
CONNECT DOWNSPOUT TO SEWER | NORTH ELEVATION / DOWNSPOUT - BOTTOM SECTION MISSING. | 6128 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / SIDING SECTION - 2NF MISSING. | 6128 S BISHOP ST | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT OF BUILDING / EXTERIOR DOOR / BURGLAR GATE - AT 1ST FL | 6128 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR ROOF | REAR ENCLOSED PORCH/ ROOF - BUCKLED AND SAGGING. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BUILDING/ 1ST FLOOR / WEST BED ROOM DOOR - BROKEN. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS [INCLUDING ELECTRIC] INSTALLED IN THE BASEMENT FORMING ROOMING UNITS AND PARTITIONS FORMING ROOM ON REAR ENCLOSED PORCH. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT ENTRANCE DOOR - GATED AND PADLOCKED. (UNABLE TO EXIT FROM INTERIOR).REAR YARD GATE - CHAINED AND PADLOCKED. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1ST TO 2ND FLOOR INTERIOR STAIRWAY/ STAIR RAILING - LOOSE, BROKEN AND WEAK; UNDERSIZED. | 6128 S BISHOP ST | COMPLAINT | FAILED | View |