Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SAFE WORKING CONDITIONS | BASEMENT HEATING SYSTEM IS NOT WORKING. (GAS IS SHUT OFF). | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING DETECTORS IN BASEMENT. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING DETECTORS IN BASEMENT. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | HOT WATER IS 60 DEGREES. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7011) 18-28-711 CARBON MONOXIDE DETECTORS 18-28-101.3 CARBON MONOXIDE DETECTORS, CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS 18-9-908.7 THROUGH 18-9-908.12 AND 18-35-3517 FOR RESIDENTIAL OR INSTITUTIONAL OCCUPANCIES COVERED IN THE ABOVE SECTIONS | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REMOVE | REMOVE DEBRIS FROM CHIMNEY THAT IS BLOCKED | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | SPECIFICALLY, THE FIRST FLOOR AND BASEMENT OCCUPANTS ARE USING THE STOVE FOR HEAT. DANGEROUS AND HAZARDOUS CONDITION. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SPECIFICALLY, REAR TWO STORY WOOD PORCH MISSING SPINDLES, A DANGEROUS AND HAZARDOUS CONDITION. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | SPECIFICALLY, THE AREA DRAIN IN THE BASEMENT WALK WAY IS HOLDING WATER, ROD DRAIN | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALLATION OF ELECTRICAL CONDUIT, BOXES,WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE BASEMENT, FIRST FLOOR UNIT AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING WITHOUT ROUGH INSPECTION. ROUGH INSPECTION REQUIRES ALL WALLS AND CEILINGS TO BE OPENED PURSUANT TO 13-12-380 CODE. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | SPECIFICALLY , THERE IS A WATER DAMAGED CEILING WITH A HOLE IN IT IN THE BASEMENT BATHROOM AREA, A DANGEROUS AND HAZARDOUS CONDITION | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROVIDE A WATER MAIN GROUND NCONDUCTOR, CONDUIT RUN TO WITHIN FIVE FEET OF WATER METER OR VALVE, 18-27-250.50 | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
ENGAG LIC & BOND PLMBNG CNTRC | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
CONTINUITY OF RACEWAY | SPECIFICALLY,PROVIDE GROUND CONTINUITY FOR CONDUIT APART AT FITTING AT REAR PORCH AREA, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
1-HR HEATING PLANT SEPARATION | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
PROPER MATRL WATER SUPPLY PIPE | SPECIFICALLY, REMOVE THE FLEX WATER LINES TO THE BASEMENT WATER HEATER AND INSTALL APPROVED PIPE AND MATERIALS, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | SPECIFICALLY NO ENTRY TO THE SECOND FLOOR DWELLING UNIT, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
NO PERMIT WIRING | SPECFICALLY, OBTAIN AN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVISES, AND ELECTRICAL EQUIPMENT WITHOUT PLANS AND PERMITS THROUGHOUT THE BASEMENT, FIRST FLOOR AREA AND OTHER TYPICAL UNITS THROGHOUT THE BUILDING 13-12-360 CODE | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL COVERS | SPECIFICALLY, PROVIDE PROPER TYPE COVER FOR OPEN BOX AT EXTERIOR SIDE GANG WAY AREA WITH DEFECTIVE LIGHT AND MISSING COVERS AT MOGUL LB BY METER BOX AREA, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
ROACHES | SPECIFIALLY, THE BASEMENT AND FIRST FLOOR ARE FULL OF JUNK AND DEBRIS, A DANGEROUS AND HAZARDOUS CONDITION, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | SPECIFICALLY THE BASEMENT WAS ORIGINALLY STORAGE AND HEATING PLANT ROOM NOW A COMPLETE DWELLING UNIT CONSISTING OF BEDROOMS A BATHROOM A KITCHEN, AND HEATING PLANT ROOM AND THE FIRST FLOOR HAS REHABBED ROOMS AND WALLS ALTERED FROM ORIGINAL LAYOUT | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO WORKING SMOKE DETECTORS OBSERVED IN BASEMENT OR FIRST FLOOR, A DANGEROUS AND HAZARDOUS CONDITION | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | SPECIFICALLY THE FRONT TOP SECTION OF PARAPET WAS REPAIRED WITH NEW SPLIT FACE LIME STONE NOT TIED IN PROPERLY ON EAST AND WEST SIDES WITH AN OPEN CAVITY WITH NO SIGNS OF COPING OR FLASHING INSTALLED, DANGEROUS AND HAZARDOUS CONDITION, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH DEVICE | SPECIFICALLY, THE FIRST FLOOR TOILET IS RUNNING AND LEAKING WATER, WHICH NEEDS TO BE STOPPED, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR YARD, USED AS PARKING LOT IS FULL OF RUTS. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | BASEMENT UNIT IS 65 DEGREES | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND WEST ELEVATION WALLS HAVE MORTAR WASHED OUT AND BRICKS SPALLING. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
PARAPET | PARAPET AT EAST AND WEST ELEVATION HAS BRICKS AND MORTAR SPALLING. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CONCRETE SLAB AT BASEMENT LEVEL REAR, UNDER PORCH IS BROKEN AND UNEVEN AND SEWER. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING DETECTORS AT 1ST AND BASEMENT. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT COMPLETE PLANS AND OBTAIN PERMIT FOR ALTERATIONS TO PREMISE. 1ST FLOOR AND BASEMENT REHABED, BASEMENT IS BEING USED AS A DWELLING UNIT AND NEW PORCH ERECTED AND NEW ELECTRIC SERVICE. INCLUDE ALL LEVELS, PLUMBING, ELECTRICAL AND VENTILATION. NO PERMITS ON RECORD. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | SPECIFICALLY, THE FURNACE ON THE FIRST FLOOR AND BASEMENT WERE NOT WORKING AT THE TIME OF INSPECTION. | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | SPECIFICALLY, REMOVE ALL PARTIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRICAL) INSTALLED IN THE BASEMENT AND FIRST FLOOR ( AND SECOND FLOOR IF TYPICAL) WITHOUT A PERMIT, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
RATS | SPECIFICALLY, THE BASEMENT AND FIRST FLOOR ARE RODENT INFESTED, A DANGEROUS AND HAZARDOUS CONDITION, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SPECIFICALLY, THE FURNACE ROOMS IN THE BASEMENT AND FIRST FLOOR ARE FULL OF JUNK AND DEBRIS, A DANGEROUS AND HAZARDOUS CONDITION | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | SPECIFICALLY, THE BASEMENT KITCHEN SINK WASTE PIPE IS LEAKING AND NEEDS TO BE REPAIRED OR REPLACED, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | SPECIFICALLY, THE BASEMENT KITCHENSINK COUNTER AND CABINET ARE FALLING APART AND NEED TO BE REPLACED, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
STOP LEAKING WATER | SPECIFICALLY, REPAAIR THE TUB WASTE IN THE FIRST FLOOR CEILING THAT IS LEAKING INTO THE BASEMENT BATHROOM, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | SPECIFICALLY, THE FIRST FLOOR LAVATORY IS LOOSE AND NEEDS TO BE RESET, | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
PRV FLUE FOR HOT WATER HEATER | SPECIFICALLY, THE FIRST FLOOR WATER HEATER FLUE PIPE IS NOT THE PROPER SIZE OR ATTACHED PROPERLY | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION FOR ALL KITCHEN COUNTER TOP ARTES, THE BATHROOM AND LAUNDRY AREAS OF THE BASEMENT, AND THE FIRST FLOOR UNIT PURSUANT TO 18-27-570.8 | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |
THE LOCATION OF THE SERVICE DISCONNECTS SHALL BE IN THE BASEMENT OR FIRST FLOOR WITHIN THE BUILDING AND NOT MORE THAN FIVE FEET FROM THE POINT OF ENTRY PURSUANT, 18-27-230.70 | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
BOND ALL ELECTRICAL PANELS SO AS TO ESTABLISH AN EFFECTIVE PATH FOR FAULT CURRENT 18-27-250.2 CODE | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View | |
STRUCTURAL MEMBER, PIER BLOCK | 4540 W JACKSON BLVD | COMPLAINT | FAILED | View |