Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 7749 S AVALON AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7749 S AVALON AVE | REGISTRATION | CLOSED | View | |
REPAIR PORCH SYSTEM | (WEST ELEVATION) FRONT PORCH - 4X4 COLUMNS ARE ONLY SET ON TOP OF BRICKS,NORTH BRICK IS BROKEN AND SPALLED,MISSING FOOTING. MOST MEMBERS ARE ONLY TOE NAILED/ SCREWED AT THE CONNECTIONS OBTAIN PERMIT FOR REPAIRS. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |
REPAIR BAY WALL | (WEST ELEVATION) BAY WALL FIRE DAMAGE,CHARRED FLOOR JOISTS,EDGE BEAM AND SUB-FLOOR.FRONT PORCH IS ATTACHED TO THE NORTH WALL WITH ONLY ONE COLUMN FOR SUPPORT.SUBMIT PLANS / OBTAIN PERMIT FOR REPAIRS. DANGEROUS AND HAZARDOUS CONDITION. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | (EAST ELEVATION) REAR ENCLOSED PORCH (1 STORY) SOUTH 6X6 COLUMN IS ROTTED THROUGH, NORTH- SOUTH 4X4 COLUMN IS ONLY SET ON TOP OF A BRICK MISSING FOOTINGS.ROTTED EDGE BEAMS.WORN STRINGERS,ROTTED TREADS,MISSING RISER.LOOSE HANDRAILS.MOST MEMBERS ARE ONLY TOE NAILED / SCREWED AT THE CONNECTIONS.SAGGING ROOF. SUBMIT PLANS/ OBTAIN PERMIT FOR PEPAIRS. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | (SOUTH ELEVATION) EXTERIOR STAIRS (2 STORY) ENTIRE FLIGHT SHIFTS LATERALLY UPON LOAD 4X4 COLUMNS ARE ONLY SET ON TOP OF THE FRACTURED SPALLED CONCRETE SERVICE WALK,MISSING FOOTINGS. MOST MEMBERS ARE ONLY TOE SCREWED/ NAILED AT THE CONNECTIONS. SUBMIT PLANS / PERMIT FOR REPAIRS. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR FROM FRONT TO REAR OF BUILDING. FLOOR COVERED WITH CARPET UNEVEN,WEAK AND DEFLECTING WHEN WALKED WHEN WALKED UPON. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | BASEMENT CEILING JOISTS (AS SEEN FROM BASEMENT) MIXED 2X6 & 2X8 JOISTS SPAN 11 FEET.PREVIOUS FIRE DAMAGE REPAIR OF FLOOR STRUCTURE INADEQUATE, UNSAFE.SOME JOISTS MISSING CREATING 32 @ O.C.VERTICAL SUPPORT COLUMNS ROTTED AT BASE. PLANS & PERMIT REQUIRED FOR REPAIRS. | 7749 S AVALON AVE | COMPLAINT | FAILED | View |