The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT AREAWAY NO GUARDRAILS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNER I.D. SIGN POSTED | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 1ST FLOOR BROKEN PANE | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | WEST ELEVATION DOWNSPOUT MISSING SECTION | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | NORTH ELEVATION - CHIMNEY CAP OPEN JOINTS | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING - NO ENTRY | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 1ST FLOOR BROKEN PANE | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | WEST ELEVATION DOWNSPOUT MISSING SECTION | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING - NO ENTRY | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH AND SOUTH ELEVATIONS I BEAM AT WINDOWS HEADER RUSTED | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY WEST AND SOUTH EAST ERODED MORTAR, LOOSE BRICKS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK REAR UNLEVEL AND BROKEN CONCRETE AT BASEMENT | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | EAST ELEVATION YARD STOOP CRACKED CONCRETE ADJACENT TO WALK | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT STAIRS IMPROPER HANDRAIL NO BALUSTERS IN RAILINGS. LOOSE AND INSUFFICIENT HEIGHT | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | REAR BASEMENT RETAINING WALL MISSING MASONRY CRACKED MORTAR | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL NORTH BASEMENT WINDOWS AND (1) ONE SOUTH BBOARDED | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | NORTH AND REAR ELEVATION DOWNSPOUT DRAINGIN ONTO ADJACENT VACANT LOT (SEC. 18-29-1101.2.1) | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMIT REQUIRED TO ENCLOSE BASEMENET WINDOWS WITH BRICK | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | WATER DRAINAGE INTO ADJACENT LOTS, STANDING WATER | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS VARIOUS LOCATIONS OPEN MORTAR JOINTS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS NORTH AND SOUTH ERODED MORTAR OPEN JOINTS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | NORTH AND SOUTH PARAPET ERODED MORTAR OPEN JOINTS, MISSING COPINGS ON SOUTH ELEVATION BRICKS LOOSE AND SPALLING | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | PERIMETER AND REAR LOT TRASH AND DEBRIS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR REAR ELECTRIC FENCE OVER (6) SIX FEET. | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR MASONRY WORK TO BE PERFORMED | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL WINDOWS AT GRADE DILAPIDATED PLYWOOD | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
RATS | REAR LOT EVIDENCE OF RATS HARBORING | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN WOOD PORCH NO FOOTINGS BASE OF COLUMNS, SEATED DIRECTLY ON CONCRETE. 1ST FLOOR BEAM NOT CEMENTED INTO POCKET 1ST FLOOR JOIST SECTION SPLIT AT BEAM CONNECTION SPLIT TREADS 1ST FLOOR GUARDRAIL AND COLUMN CONNECTION GAP SPLIT WOOD AT BOTTOM 2ND FLOOR GUARDRAIL TOP AND BOTTOM MEMBERS PIECED TOGETHER GAP AT COLUN CONNECTION ALL LEVELS GUARDRAILS LESS THAN 42" HIGH AND NOT PROPERLY ATTATCHED TO WALL NO BOLTS 2ND FLOOR DECK BOARD REAR STAIRS UNSUPPORTED WEAK 3RD FLOOR SPLIT DECKING SECTION PIECED TOGETHER LOOSE 3 SOUTH RAILS PULLING AWAY FROM WOOD ALL LEVELS VARIOUS LOCATIONS ALL LEVELS WALL STRAPS MISSING AT SEVERAL BEAM POCKETS INSUFFICIENT T BRACKETS INSTALL STEEL FACE PLATES AND ANGLES AT CONNECTIONS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED TO REPAIR OR REPLACE REAR PORCH | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED TO CONVERT (63) UNITS INTO 6 UNITS | 4420 S VINCENNES AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPAIR COPING | EAST ELEVATION - COPING TILES - MISSING. | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - CEMENT PARGE BETWEEN 3RD FLOOR AND ROOF - SPALLING AND LOOSE. | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2018 ANNUAL INSPECTION. | 4420 S VINCENNES AVE | PERIODIC | FAILED | View |