REPAIR EXTERIOR WALL | SOUTH ELEVATION ROTTING SIDING. | 5343 N FRANCISCO AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION ROTTING WINDOW FRAME AND SILL AT 1. EAST ELEVATION WINDOW FRAME, SILL AND CASING AT 1 ROTTING. | 5343 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY PORCH- SCREENED ENCLOSURE PORTION- COLUMNS IN SOIL, NO FOUNDATIONS. ROTTING AND LOOSE COLUMNS. ROTTING RIM JOIST. ENCLOSURE SINKING. JOISTS, BEAMS, COLUMNS, STRINGERS, RAILS, POSTS, ALL MEMBERS ANCHORED WITH NAILS ONLY. 2X8 JOISTS SPAN 12'. OPEN AND LADDER TYPE RAILS. LOOSE AND DEFLECTING RAILS. ROTTING ENCLOSURE ROOF DECKING. OPEN EAVES. RISERS VARY IN HEIGHT FROM 6 1/2" TO 9''. DECK AT 2 WITH 2X8 JOISTS SPANNING OVER 13'. 36'' GUARD RAILS. OBTAIN COMPLETE PLAN AND PERMIT. | 5343 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | NO SMOKE DETECTOR UNIT 1S. | 5343 N FRANCISCO AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CO DETECTOR UNIT 1S. | 5343 N FRANCISCO AVE | COMPLAINT | FAILED | View |