Chicago Building Violations Data: 7 Violations
Violation Inspector Comments Address Category Status View
PARAPET PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. 3343 N TROY ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH1. 4X4 COLUMNS RESTING ON CONCRETE PADS SET IN DIRT.2. FOUNDATION STATUS UNKNOWN.3. 2X6 JOIST OVER SPANNED AND INADEQUATELY SUPPORTED.4. STRINGERS OVERCUT, SPLIT AND INADEQUATELY SUPPORTED.5. PLANS AND PERMIT REQUIRED.REAR PORCH1. 6X6 COLUMNS STACKED AND TOENAILED.2. LOOKOUT BEAMS OVER SPANNED.3. INADEQUATE BEAM TO COLUMN CONNECTIONS.4. 2X4 JOIST AT LANDINGS TOENAILED.5. STRINGERS INADEQUATELY SUPPORTED.6. STAIR TREADS TOO SMALL.7. 2X8 JOIST OVER SPANNED.8. GUARDRAILS TOO LOW.9. PLANS AND PERMIT REQUIRED. 3343 N TROY ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 3343 N TROY ST COMPLAINT FAILED View
PARAPET PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. 3343 N TROY ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT PORCH1. 4X4 COLUMNS RESTING ON CONCRETE PADS SET IN DIRT.2. FOUNDATION STATUS UNKNOWN.3. 2X6 JOIST OVER SPANNED AND INADEQUATELY SUPPORTED AT BEAMS.4. STRINGERS OVERCUT, SPLIT AND INADEQUATELY SUPPORTED.REAR PORCH1. 6X6 COLUMNS STACKED AND TOENAILED AT JOINTS.2. LOOKOUT BEAMS OVER SPANNED.3. BEAM TO COLUMN CONNECTIONS INADEQUATE.4. 2X4 JOIST INADEQUATELY SUPPORTED AT BEAMS.5. STRINGERS INADEQUATELY SUPPORTED.6. STAIR TREADS UNDERSIZED.7. 2X8 JOIST OVER SPANNED.8. GUARDRAILS UNDER 42 INCHES IN HEIGHT.9. PLANS AND PERMIT REQUIRED FOR BOTH PORCHES. 3343 N TROY ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 3343 N TROY ST COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# NO OWNER'S / MANAGEMENT SIGN POSTED. 3343 N TROY ST COMPLAINT PASSED View