Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY | CHIMNEY MORTAR MISSING | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL LOOSE BRICKS DETERIORATING MORTAR MISSING | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EAST EXTERIOR DOOR FRAME TRANSON BROKEN | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | 1ST FLOOR DINING ROOM LIGHT FIXTURE MISSING | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1ST FLOOR BATHROOM CEILING BUCKLING KITCHEN CEILING CRACKED PLASTER 2ND FLOOR KITCHEN CEILING BATHROOM HALLWAY CEILING BUCKLING CRACKED PLASTER | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR BATHROOM WALL TILES MISSING OR BROKEN | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST AND 2ND FLOOR BATHROOM FLOOR ROTTED | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH TREADS RISERS STRINGERS RAILS UPRIGHTS DANGEROUS AND HAZARDOUS ROTTED REPLACE 4X4' WITH 6X6 UNSTABLE SYSTEM | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH ELEVATION STONE CHIMNEY CAP MISSING. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION 2 STORY WOOD PORCH REPLACE FROM ORIGINAL.GUARDRAILS 36" HIGH,LOOSE AND MISSING PICKETS VERY UNSTABLE AND TOENAILED TO COLUMNS.TRIPLE 2X10 RIM JOIST FASTENED WITH LIGHT GAUGE METAL BOLTS AND BRACKETS NOT BEARING.CONCRETE PIERS ARE SMALLER THAN 6X6 COLUMNS,STATUS OF FOUNDATIONS UNKNOWN.INTERMEDIATE LANDING HAS ONLY 2FT OF CLEARANCE BETWEEN GUARDRAIL AND STAIRS.PLAN AND PERMIT REQUIRED TO REPAIR PORCH. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION PARAPET WALL SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH ELEVATION CHIMNEY HAS SPALLING/CRUMBLING BRICKS AND WASHED OUT MORTAR JOINTS. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EXCESSIVE STORAGE ON BACK PORCH AND INTERIOR FRONT STAIRS.NORTH ELEVATION 1ST AND 2ND BACK DOOR SCISSOR GATES AND PADLOCKED WHILE AT HOME. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST,2ND AND FRONT HALLWAY MISSING SMOKE DETECTORS. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST,2ND, AND BASEMENT CARBON MONOXIDE DETECTOR MISSING. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | 2ND FLOOR MUCH CLUTTER AND UNSANITARY CONDITIONS. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BASEMENT,1ST FLOOR FRONT AND REAR ENTRY DOORS MISSING ENTRY LOCKS. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 1ST FLOOR FRONT COMMON ENTRY DOOR DISCONNECTED DOOR CLOSER. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | APARTMENT DOOR NO PEEPHOLES | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATION PARAPET WALLS - SPALLING BRICKS AND WASHED OUT MORTAR. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH AND SOUTH ELEVATION CHIMNEYS - SPALLING BRICKS AND WASHED OUT MORTAR. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT ENTRY AREA - MISSING GUARDRAIL. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH - LEDGER BEAMS AT 1ST AND 2ND FLOOR - INSUFFICIENT NUMBER OF BOLTS USED TO ATTACH BEAM TO BUILDING.GUARDRAILS ONLY 36 INCHES IN HEIGHT AND MISSING INTERMEDIATE SUPPORT POST.DOUBLE 2X10 BEAMS ARE NAILED TO SUPPORTS.STRINGERS ARE WRAPPED UNDER HEADERS AND NAILED TO JOIST OR BUILDING.HEADROOM AT GRADE IS ONLY 6 FEET.PLANS AND PERMIT REQUIRED. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - HEADROOM AT GRADE UNDER PORCH IS ONLY 6 FEET. REAR PORCH - CLEAR PATH OF TRAVEL AT LANDING IS ONLY 24 INCHES. | 5936 S EMERALD AVE | COMPLAINT | FAILED | View |