Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:09 PM
PIN: 20184010210000
Property Address: 5941 S WINCHESTER AVE
City - Zip: CHICAGO - 60636
2023 Property Class: 202
2023 Township: 72 - Lake
2023 Neighborhood: 72120
2023 Tax District: 72163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 37 Violations
Violation Inspector Comments Address Category Status View
CARPETING TORN INDOOR - OUTDOOR CARPETING 5941 S WINCHESTER AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM IMPROPER PICKET SPACED TOO FAR APART; LOOSE RAILINGS 5941 S WINCHESTER AVE COMPLAINT CLOSED View
PERMIT REQUIRED - CONTRACTOR PERMIT FOR WOOD (6) SIX FOOT FENCE 5941 S WINCHESTER AVE COMPLAINT CLOSED View
NO POSTED ADDRESS POST FULL ADDRESS ON BUILDING 5941 S WINCHESTER AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION ARRANGE FOR FULL INTERIOR INSPECTION 5941 S WINCHESTER AVE COMPLAINT CLOSED View
DEBRIS, EXCESSIVE LOT WITH JUNK 5941 S WINCHESTER AVE COMPLAINT CLOSED View
REPLACE DEFECTIVE PLBG FIXTURE REPAIR OR REPLACE LOOSE GUTTER IN REAR OF THIS BUILDING 5941 S WINCHESTER AVE COMPLAINT CLOSED View
SECURE SEC STRAP AND SECURE SERVICE ENTRANCE CABLE 5941 S WINCHESTER AVE COMPLAINT CLOSED View
SECURE RACEWAY STRAP AND SECURE CONDUIT AT FRONT BASEMENT 5941 S WINCHESTER AVE COMPLAINT CLOSED View
SERVICE WALK, PASSAGE, AREAWAY SOUTH - SERVICE WALK BROKEN, CRACKED. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR REAR - GRADE TO BASEMENT - MISSING HAND AND GUARD RAILS. 5941 S WINCHESTER AVE COMPLAINT PASSED View
DEBRIS, EXCESSIVE BASEMENT - REMOVE JUNK ACCUMULATION. 5941 S WINCHESTER AVE COMPLAINT PASSED View
CARPETING FRONT PORCH STAIRS - REMOVE TORN CARPET. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR PORCH - MISSING PICKETS, UNDER 42 INCHES. 5941 S WINCHESTER AVE COMPLAINT PASSED View
CONTRARY TO ORIGINAL PLAN ATTIC - STORAGE SPACE HAS BEEN CONVERTED TO A DWELLING UNIT. 5941 S WINCHESTER AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR ATTIC - SUBMIT PLANS AND PERMITS FOR DECONVERSION. 5941 S WINCHESTER AVE COMPLAINT PASSED View
STAIRWELL ENCLOSURE ATTIC - WOOD, LATH AND PLASTER DOES NOT PROVIDE A 1 HOUR FIRE RATING. 5941 S WINCHESTER AVE COMPLAINT PASSED View
SEPARATION OF DWELLING ATTIC - PROVIDE A 1 HOUR FIRE RATING FOR DWELLING SEPARATION. 5941 S WINCHESTER AVE COMPLAINT PASSED View
CEILING HEIGHT - 7' ATTIC - CEILING HEIGHT LESS THAN 7 FEET. 5941 S WINCHESTER AVE COMPLAINT PASSED View
LIGHT AND VENT ATTIC - ALL ROOMS USED FOR HUMAN OCCUPANCY MUST PROVIDE A EIGHT PERCENT NATURAL LIGHT AND 4 PERCENT VENTILATION. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR FLOOR BATH ROOM FLOOR 1ST FLOOR - MISSING FLOOR TILE. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR EXTERIOR STAIR - MISSING HAND AND GUARD, REAR GRADE TO BASEMENT. 5941 S WINCHESTER AVE COMPLAINT PASSED View
PRV CAST IRON COVER FOR BASIN MISSING CATCH BASIN COVER IN REAR. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR OR REPLACE CONNECT DOWNSPOUT TO SEWER IN REAR (18-29-1101) 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPLACE DEFECTIVE FAUCET KITCHEN SINK 1ST FLOOR DRIPS. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPLACE DEFECTIVE PLBG FIXTURE CRACKED LAUNDRY TUB 5941 S WINCHESTER AVE COMPLAINT PASSED View
REMV OBSTR FROM DRAINAGE SYSTM ROD OUT LAUNDRY TUB 5941 S WINCHESTER AVE COMPLAINT PASSED View
PRV WATER AT PLUMBING FIXTURE LOW WATER PRESSURE THROUGHOUT BUILDING. 5941 S WINCHESTER AVE COMPLAINT PASSED View
PRV WATER PIPES PROPER SIZE UNDERSIZED WATER LINES AT WATER HEATER & TRUCK LINES. 5941 S WINCHESTER AVE COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV EXTEND RELIEF VALVE DISCHARGE PIPE AT WATER HEATER IN BASEMENT. 5941 S WINCHESTER AVE COMPLAINT PASSED View
OBTAIN PERMIT FOR PLUMBING TO CORRECT ALL PLUMBING VIOLATIONS. 5941 S WINCHESTER AVE COMPLAINT PASSED View
REPAIR DEFECTIVE FITTINGS PROVIDE DIELECTRIC UNIONS AT ALL DOMESTIC WATER LINES WHEN METALS OF DISSIMILAR MATERIAL COLLIDE AT WATER HEATER. 5941 S WINCHESTER AVE COMPLAINT PASSED View
SECURE RACEWAY LOOSE EMT. AT BASEMENT. 5941 S WINCHESTER AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTORS 5941 S WINCHESTER AVE COMPLAINT PASSED View
PRV FLOOR DRAIN WITH METAL STR MISSING FLOOR DRAIN GRATE. 5941 S WINCHESTER AVE COMPLAINT PASSED View
UNAPPROVED CORDS EXTERIOR CORD BASEMENT. 5941 S WINCHESTER AVE COMPLAINT PASSED View
WORK NOT ALLOWED ATTIC - RESTORE SPACE TO ITS ORIGINAL CONFIGURATION. 5941 S WINCHESTER AVE COMPLAINT PASSED View