Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 6:37 PM
PIN: 14053060010000
Property Address: 5920 N RIDGE AVE
City - Zip: CHICAGO - 60660
2023 Property Class: 318
2023 Township: 73 - Lake View
2023 Neighborhood: 73011
2023 Tax District: 73005
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 24 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY INSUFFICIENT HEAT, UNIT 214 66 DEGREES LIVING ROOM AND 65 DEGREES BED ROOM. 205 66 DEGREES LIVING ROOM, 202 66 DEGREES BED ROOM. 5920 N RIDGE AVE COMPLAINT PASSED View
SAFE WORKING CONDITIONS UNIT 209 RADIATOR BROKEN, DETACHED, NOT SUPPLYING HEAT. 5920 N RIDGE AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS UNIT 201 NO SMOKE DETECTOR. 5920 N RIDGE AVE COMPLAINT PASSED View
HEAT UNIT ADEQUATELY APT.301 - ROOM TEMPERATURE 58F AT 12:10PM. HEATING SYSTEM OFF AT TIME OF INSPECTION. NO HEAT PROVIDED. 5920 N RIDGE AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE APT.301 - BEDROOM WINDOW PANE BROKEN. CARDBOARD IN WINDOW. 5920 N RIDGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS APT.301 /BEDROOM WINDOW PANE - BROKEN. 5920 N RIDGE AVE COMPLAINT FAILED View
STOP SMOKE, NOXIOUS ODORS APT.301 - NOXIOUS ODORS. 5920 N RIDGE AVE COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY APT.301 - FILTHY AND UNSANITARY CONDITIONS. GARBAGE, JUNK, PERSONAL ITEMS SCATTERED THROUGHOUT ENTIRE APARTMENT. UNABLE TO SEE THE FLOOR. BATHROOM TOILET COVERED WITH FECES. 5920 N RIDGE AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE UNIT 305 AND UNIT 302- WINDOWS NOT CLOSING PROPERLY, TOP PORTION IS DOWN AND WILL NOT STAY UP AND LATCH IN PLACE, GAPS, SIGNIFICANT AIR INFILTRATION. 5920 N RIDGE AVE COMPLAINT PASSED View
HEAT UNIT ADEQUATELY UNIT 305- 65 DEGREES. UNIT 302 65 DEGREES. 5920 N RIDGE AVE COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG INTERIOR ALL FIRE EXSTINGUISHERS OUT DATED TAGS. 5920 N RIDGE AVE COMPLAINT PASSED View
MAINTAIN EXIT SIGN ILLUMINATED INTERIOR 2ND FLOOR CORRIDOR STAIRWELL SIGN NOT ILLUMINATED. 5920 N RIDGE AVE COMPLAINT PASSED View
FILE BLDG REGISTRATION BUILDING PROVIDE EVIDENCE OF REGISTRATION FOR 1990 -2011. 5920 N RIDGE AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR INTERIOR ALL CORRIDORS DROPPED DRY WALL FRAME CEILING, NO PERMIT ON SITE. ALL CORRIDOR LIGHT FIXTURES BEING REPLACED WITHOUT PERMIT. CALLED 311 MS WARD CSR 1100062511. 5920 N RIDGE AVE COMPLAINT PASSED View
PROVIDE MINIMUM VENT QUANTITY (1) INCREASE SUPPLY AND EXHAUST C.F.M. SIZES TO WEIGHT RM IN BASEMENT TO MEET MIN. REQUIREMENT (2) PROVIDE SUPPLY AND EXHAUST TO REAR PUNCHING BAG AREA IN BASEMENT THAT CURRENTLY HAS NO VENTILATION 18-28-403 18-28-403.3 5920 N RIDGE AVE COMPLAINT FAILED View
PROVIDE SUPPLY PROVIDE SUPPLY VENTILATION TO BASEMENT GYM ROOMS AT RATE OF 2 C.F.M. PER SQ FT OF FLOOR AREA 18-28-403.3 5920 N RIDGE AVE COMPLAINT FAILED View
GIVE VENT OPENINGS % FL. AREA PROVIDE EXHAUST VENTILATION TO BASEMENT GYM ROOMS AT RATE OF 1.5 C.F.M. PER SQ FT OF FL AREA 18-28-403.3 5920 N RIDGE AVE COMPLAINT FAILED View
PROVIDE FRESH AIR SUPPLY UNIT MUST BE PROVIDED WITH SOME TYPE OF HEAT ELEMENT 34(13-196-750) 5920 N RIDGE AVE COMPLAINT FAILED View
REPAIR OR REPLACE REPAIR SMASHED AND DISCONNECTED DUCTWORK ON EXTERIOR WALL AND IN BOILER RM. 5920 N RIDGE AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 7011) PROVIDE CARBON MONOXIDE DETECTORS IN BOILER RM AND IN GYM SPACE. 5920 N RIDGE AVE COMPLAINT FAILED View
ARRANGE ANNUAL INSP. ARRANGE INSPECTION AFTER VIOLATIONS ARE CORRECTED 13-20-290 13-20-020 LARGE RM APPROX. 3700 SQ FT (INSUFF. VENT) SMALLER RM APPROX 1630 SQ FT (NO VENT) 5920 N RIDGE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS SEE DEFECT NOTICE # 12492 5920 N RIDGE AVE PERMIT PASSED View
HEAT UNIT ADEQUATELY UNIT #301 - ROOM TEMPERATURES WERE 66-71 DEGREES AT TIME OF INSPECTION; INSUFFICIENT HEAT PROVIDED 5920 N RIDGE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID UNIT #301 - CARBON MONOXIDE DETECTOR - MISSING 5920 N RIDGE AVE COMPLAINT FAILED View