The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCKS. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | EAVES - MISSING SECTION OF METAL CLAD. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - MISSING SECTION OF SIDING. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK - DIRT AND GRAVEL; UNEVEN SURFACE; MISSING HARD SURFACE. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - MISSING SECTIONS OF SIDING AND DOWNSPOUTS. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | REFUSED ENTRY BY HOMEOWNER - UNVERIFIED COMPLAINT OF HOLES IN CEILING AND KITCHEN SINK; BAD SMELL COMING FROM SINK; ROACHES AT APT.2. UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 1933 N KEYSTONE AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION / REAR SERVICE WALK-MISSING HARD PAVEMENT. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY HIGH ROOFED WOODEN PORCH:6X6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.LEDGER BEAM IS ONLY FACE NAILED TO BUILDING.UNDERSIZED 2X6 DECK JOISTS SPAN 10 FOOT 4 INCHES AND SUPPORTED BY A 2X4 BEAM.STRINGERS ONLY FACE NAILED AT TOP CONNECTION.METAL RAILINGS RUSTED AND ROOF SUPPORTS ARE ROTTED; RAILINGS ARE LOOSE AND PULLING AND ONLY 30 INCHES IN HEIGHT. REAR 3 STORY HIGH ENCLOSED WOODEN PORCH: 6X6 COLUMNS SET ON CONCRETE,FOUNDATION STATUS UNKNOWN.BEAM AND COLUMN CONNECTIONS ROTTED AT FIRE CUTS AND PULLING APART.BEAM AND COLUMNS ARE SPLITTING.UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET 8 INCHES.MID-LANDING JOISTS ARE 2X4 AND SPAN 7 FEET.STRINGERS ONLY FACE NAILED AT TOP CONNECTION. PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCH. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | FRONT INTERIOR STAIRS FROM 2ND FLOOR TO ATTIC BUILT WITHOUT A PERMIT.REAR 1ST AND 2ND FLOORS ENCLOSED PORCH REMODELED INTO KITCHEN AREAS WITHOUT A PERMIT.REAR EXTERIOR OVERSIZED (16 FEET BY 12 FEET) 1ST FLOOR WOODEN DECK BUILT WITHOUT A PERMIT. PLANS AND PERMIT ARE NOW REQUIRED FOR ALL THREE ALTERATIONS.SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO INSPECT REAR ENCLOSED PORCH. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS: EXTERIOR WALLS - SIDINGS REMOVED, EXPOSING WOOD BOARDS. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO INSPECT REAR ENCLOSED PORCH. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
PIGEONS-NESTING | WEST ELEVATION/PIGONS-NESTING. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS-NO ENTRY,UNABLE TO VERIFY COMPLAINT OF ILLEGAL BASEMENT APARTMENT. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING/NO ENTRY,UNVERIFIED DETECTORS,(OCCUPANCY AND CONDITIONS).NO ENTRY UNABLE TO VERIFY COMPLIANCE ON PREVIOUS VIOLATIONS,SEE INSPECTION # 11630418 OF DATE 07/06/2015. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
PROVIDE GUTTER & DOWNSPOUT | BUILDING / GUTTERS AND DOWNSPOUT-MISSING. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRCASE- MISSING HANDRAIL. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS - WINDOW SCREENS - TORN AND MISSING. | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
DEMO DEBRIS | REAR YARD - DEMO DEBRIS | 1933 N KEYSTONE AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR GATE-DOUBLE KEYED LOCKS. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | BUILDING / GUTTERS AND DOWNSPOUT-MISSING. | 1933 N KEYSTONE AVE | COMPLAINT | FAILED | View |