The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE COMPLETED PERMIT INSP. | 6515 N SEELEY AVE | PERMIT | PASSED | View | |
ARRANGE FOR RE-INSPECTION | EXCESSIVE CUPPINGS | 6515 N SEELEY AVE | PERMIT | PASSED | View |
REPLACE D&H PORCH | REAR PORCH-NORTH PORCH-ROTTED WOOD THRU-OUT, 6X6 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN, 6X6 COLUMNS OVER NOTCHED, LOOKOUT BEAMS MISSING TIE STRAPS, 2X8 JOIST OVER SPANNED (18 FEET), MISSING JOIST HANGERS, STRINGERS INADEQUATELY SUPPORTED AT COLUMNS, STAIR TREADS TOO SMALL, STRINGERS SKABBED TOGETHER, DECKING LOOSE, RAILINGS TOO LOW, SOUTH PORCH - 6X6 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN, 4X4 COLUMN USED FOR SUPPORT OVER 12 FEET HIGH, LAP JOINTS TOO SMALL, 2X8 JOIST OVER, SPANNED (14 FEET). BEAM TO COLUMN CONNECTION INADEQUATE, STRINGERS INADEQUATELY SUPPORTED, RAILING TOO LOW (39) PLANS AND PERMIT REQUIRED. | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 6525 ENTRY DOOR - PEELING VENEER | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 6521 FRONT STAIRWAY-NON WORKING SMOKE DETECTOR. | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
INSECTS | 6525 FOYER-ANTS | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 6521 APT. 25-DRAFTY WINDOWS-LARGE GAPS ON INTERIOR SIDE | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING-MISSING OWNERS I. SIGN | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 6521 2ND FLOOR-MISSING PEEP HOLES | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | 6523 ENTRY DOOR-SCREWED SHUT | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF RODENT INFESTATION. | 6515 N SEELEY AVE | COMPLAINT | FAILED | View |