Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE DISTRIBUTION | 18-27-384.13 PANELS | 3534 W 13TH PL | COMPLAINT | FAILED | View |
WORKING SPACE | 18-27-110.26 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | 18-27-230.70 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 18-27-410.22 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL COVERS | 18-27-370.25 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | 18-27-373.4 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 18-27-570.8 PROVIDE GFCI FOR KITCHEN AND BATHS | 3534 W 13TH PL | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | PUBLIC PANEL AND METER REQUIRED 18-27-210.25 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 18-27-110.2 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
ADD RECEPTACLES | 18-27-570.10 (E) ENTIRE BUILDING | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | 18-27-560.7 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | IRON FENCE AT THE FRONT OF PROPERTY OVER 5 FT. REMOVE, REDUCE HEIGHT, OR OBTAIN PERMIT FOR FENCE TO STAND AS IS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR EAVES | REAR BUILDING - MISSING SECTIONS OF EAVES AND FASCIA EAST AND WEST ELEVATIONS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR BUILDING - OPEN WOOD PORCH SYSTEM FAILING MISSING COMPONENTS. A). 4X6 COLUMNS NOT RESTING ON VERIFIED FOOTINGS. B). 6X6 COLUMNS STACKED TWISTED AT CONNECTION, RESTED ON SOIL, NO VERIFIED FOOTINGS. C). ALL CONNECTIONS NAILED ONLY, NO ANGLE BRACES WHERE REQUIRED. D). MISSING PICKETS AT INTERMEDIATE LEVEL (DANGEROUS AND HAZARDOUS). E). RAILS AT INTERMEDIATE LOOSE AND PULLING (DANGEROUS AND HAZARDOUS). F). RAILS UNDER REQUIRED 42" AT 2ND FLOOR LEVEL. G). RAILS NOT BOLTED TO PROPERTY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BUILDING - DOORS AT COACH HOUSE FRONT AND REAR ROTTED, NOT FUNCTIONING PROPERLY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
CORD TO FIXTURE | REAR BUILDING - LIGHT ON THE EXTERIOR OF THE COACH HOUSE ABOVE THE EAST DOOR HAS A CORD GOING THROUGH THE DOOR. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND JBOX | REAR BUILDING - BOX ON THE REAR SECOND FLOOR BACK PORCH AREA IS HANGING AND NOT SUPPORTED TO THE WALL PROPERLY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | REAR BUILDING - MISSING ENTRY LIGHT FIXTURE ON THE FIRST FLOOR REAR OF THE COACH HOUSE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REAR BUILDING - MISSING CORRECT FITTINGS ON THE EAST ELEVATION OF THE COACH HOUSE. (18-27-110.3)(B) | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
CORD TO FIXTURE | REAR BUILDING - HANGING ROMEX ON THE REAR OF THE COACH HOUSE LIGHT FIXTURE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS. (13-12-360) | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
EXPOSED WIRING | REAR BUILDING - EXPOSED WIRING ON THE REAR OF THE COACH HOUSE (NORTH ELEVATION). | 3534 W 13TH PL | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXSPOSED WIRING ON THE REAR OF THE COACH HOUSEAT NORTH ELEVATION | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR OF PROPERTY SOUTH ELEVATION ENTRY DOORS NOT LATCHING DEFECTIVE/MISSING HARDWARE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
MICE/RODENTS | MICE AND RODENT INFESTATION THROUGHOUT PROPERTY - EXTERMINATOR REQUIRED. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
ROACHES | ROACHES INFESTATION THROUGHOUT PROPERTY - EXTERMINATOR REQUIRED. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS THROUGHOUT AT TIME OF INSPECTION - DANGEROUS AND HAZARDOUS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | FLOORS FLEXING UNDER LIVE LOAD AT 2ND AND 3RD FLOOR LEVELS AT FRONT PROPERTY. REAR OF UNITS VISIBLY OUT OF LEVEL, SIGNS OF STRUCTURAL FAILING SPECIFICALLY IN REAR BEDROOMS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | CLASS B HEATING PLANT DOOR REQUIRED FOR ALL ENCLOSED FURNACE ROOMS, CURRENTLY HOLLOW CORE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIR SYSTEM FROM 2ND FLOOR TO 3RD FLOOR SEVERELY OUT OF LEVEL AND LEANING, SIGNS OF FAILING, REPAIRS NEEDED. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | REPAIR WALLS AT 2ND FLOOR LEVEL BATHROOM CEILING SIGNS OF WATER DAMAGE, UNFINISHED WET WALL AT THE SHOWER AREA, MISSING TILE AND BACKER BOARD. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | BLACK MOLD LIKE SUBSTANCE AT THE 2ND FLOOR LEVEL BATHROOM AREA ABOVE TUB. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR CORRECTION OF VIOLATIONS BUT NOT LIMITED TO WORK TO BE DONE THROUGHOUT PROPERTY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING MANAGEMENT/OWNER I.D. - REQUIRED NAME, ADDRESS, PHONE/CONTACT INFORMATION. (15-4-880) | 3534 W 13TH PL | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED FLEXIBLE WATER SUPPLY LINES TO 1ST, 2ND AND 3RD FLOOR BATHROOM LAVATORIES, TOILETS AND KITCHEN SINKS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED CORRUGATED PVC TUBULAR DRAINAGE PIPING TO 1ST, 2ND AND 3RD FLOOR KITCHEN SINKS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPL DEFECTIVE BATHROOM FLOOR | BATHROOM FLOORS AT 1ST, 2ND AND 3RD FLOOR ELEVATIONS NOT WATER IMPERVIOUS AND EASILY CLEANABLE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | UNAPPROVED S-TRAP WITH NO VENT AT 2ND FLOOR ELEVATION KITCHEN SINK DRAINAGE PIPING. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH TANK | TOILET TANK LEAKING WATER INTO BOWL AT 3RD FLOOR BATHROOM. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
PROVIDE | CLOTHES WASHING MACHINE WASTE DISCHARGING INTO 3RD FLOOR BATHROOM TUB. NO INDEPENDENT STANDPIPE. (18-29-403.1) | 3534 W 13TH PL | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING, OR USING PLUMBING SYSTEM. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
MISSING GFCI RECEPTACLES ON ALL THE KITCHEN COUNTERTOP AREAS. (18-27-570.8) | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
SUPPORT FIXTURES | CEILING FAN IN FIRST FLOOR UNIT DINING ROOM AREA IS NOT ATTACHED TO THE BOX PROPERLY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | MISSING COVERS ON LIGHT FIXTURES THROUGHOUT THE ENTIRE BUILDING. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | PANEL IS MISSING PROPER INTERIOR COVER IN THE PANEL AND THE PANEL COVER IS NOT PROPERLY ATTACHED TO THE FACE OF THE PANEL IN THE FIRST FLOOR UNIT OF THE FRONT BUILDING. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | WIRING EXPOSED FROM LIGHT FIXTURES IN THE CEILING OF THE SECOND FLOOR UNIT AND REAR BACK PORCH AREA. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | ADD RECEPTACLES THROUGHOUT ALL THE UNITS TO EASE THE USE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | NON-FUNCTIONING RECEPTACLES THROUGHOUT THE SECOND FLOOR UNIT AND NON-FUNCTIONING SWITCHES THROUGHOUT THE THIRD FLOOR APARTMENT. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | LIGHT FIXTURE ON REAR FIRST FLOOR EXTERIOR BACK PORCH AREA IS NOT SUPPORTED TO THE BOX. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | LIGHT FIXTURE IS MISSING FROM REAR EXTERIOR BASEMENT DOOR. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
CORD TO FIXTURE | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
REPAIR EAVES | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
LISTED FOR USE TEMP & LOCATION | MISSING CORRECT FITTING ON THE EAST ELEVATION OF THE COACH HOUSE | 3534 W 13TH PL | COMPLAINT | FAILED | View |
3534 W 13TH PL | COMPLAINT | FAILED | View | ||
REPLACE D&H PORCH | WOOD OPEN PORCH SYSTEM IS FAILING MISSING COMPONENTS | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
CORD TO FIXTURE | HANGING ROMEX ON THE REAR OF THE COACH HOUSE LIGHT FIXTURE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | DOORS AT COACH HOUSE FRONT AND REAR ARE NOT FUNCTIONING PROPERLY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | MISSING ENTRY LIGHT FIXTURE ON THE 1ST FLOOR REAR OF COACH HOUSE | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | COVERS ON THE METER BANK ARE NOT PROPERLY INSTALLED ON THE METERS | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVIVE WALK AT THE EAST ELEVATION IS UNEVEN AND NOT LEVEL. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REMOVE ALL DOUBLE KEYED LOCKS FROM ALL BEDROOM DOORS AT 2ND FLOOR LEVEL. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOORS MISSING SECTIONS AT 1ST, 2ND AND 3RD FLOOR LEVELS AT FRONT PROPERTY - TRIP HAZARDS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS AT 1ST AND 2ND FLOOR LEVELS LOW BATTERIES AT 3RD FLOOR - DANGEROUS AND HAZARDOUS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALLOW FOR FULL INTERIOR INSPECTION OF THE ENTIRE PROPERTY SPECIFICALLY BASEMENT AND COACH HOUSE AREAS NO ENTRY. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REAR BUILDING - COVERS ON THE METER BANK ARE NOT PROPERLY INSTALLED ON THE METERS. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
REAR BUILDING - OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS. (13-12-360) | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
MISSING WEATHERPROOF BOXES, LIGHTS, AND FITTINGS ON THE EXTERIOR OF THE BUILDING FOR THE LIGHTS. (18-27-110.3)(B) | 3534 W 13TH PL | COMPLAINT | FAILED | View | |
SERVICE WALK, PASSAGE, AREAWAY | REAR BUILDING - SERVICE WALK AT THE EAST ELEVATION UNEVEN NOT LEVEL, TRIP HAZARD. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | INADEQUATE AND DETERIORATED 18-27-230.2 | 3534 W 13TH PL | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING IS AT THE REAR EXTERIOR BASEMENT DOOR. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 3534 W /APT 1R - USING STOVE AND POT OF BOILING WATER AS HEATING DEVICE. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 3534 W /APT 1R - TEMPERATURES FOUND AT TIME OF INSPECTION (8:56AM) WERE 60F AT REAR KITCHEN AREA AND 60F A BEDROOM. HEATING SYSTEM OFF AT TIME OF INSPECTION. NO HEAT PROVIDED. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 3534 W /APT 1R FURNACE - OUT OF SERVICE AT TIME OF INSPECTION. NO HEAT PROVIDED. | 3534 W 13TH PL | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. | 3534 W 13TH PL | PERIODIC | FAILED | View |