Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR LINTELS | RUSTING LINTELS: EAST ELEVATION, WEST ELEVATION | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION, SOUTH DOOR: BROKEN PANEL | 6816 N CLARK ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINT: FRONT ELEVATION, SOUTH END DOOR, LINTELS, EAST ELEVATION CONCRETE, YELLOW SIGN BOARD, EAST ELEVATION, NORTH END | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION: BOWING & LEANING BRICK WALL, YELLOW SIGN BOARD, EAST ELEVATION, NORTH END LEANING, ROTTING, LOOSE, WEST ELEVATION: BRICK WALL LEANING WEST, BOTH FRONT AND BACK WALLS SIGNIFICANTLY LEANING; SOUTH ELEVATION: ERODING MORTAR & SPALLING BRICK; EAST ELEVATION: SEVERAL OPEN MORTAR JOINTS & FRACTURES; WEST ELEVATION: SEVERAL SEVERE FRACTURES, SOUTH END; WEST ELEVATION: FRACTURES, ERODING MORTAR, SPALLING BRICK | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION, WEST ELEVATION, NORTH OVERHEAD DOOR: EXPOSED AGRAGATE, CRUMBLING, BROKEN CONCRETE | 6816 N CLARK ST | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION PARAPET, NORHT END: FRACTURES, LOOSE BRICK, ERODING MORTAR, SPALLING BRICK; SOUTH ELEVATION, PARAPET: LOOSE BRICK, ERODING MORTAR, SPALLING BRICK; WEST ELEVATION, SOUTH END: FRACTURES, SPALLING BRICK, ERODING MORTAR | 6816 N CLARK ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | OBTAIN STRUCTURAL ENGINEER REPORT FOR STRUCTURAL INTEGRITY OF BUILDING | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANE - 1ST FLOOR EAST ELEVATION. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | MULTIPLE CRACKS ON FRONT COLUMNS - EAST ELEVATION. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | RUSTED LINTELS EAST ELEVATION OVERHEAD DOOR. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | BROKEN ENTRANCE DOOR PANEL - EAST ELEVATION SOUTH DOOR. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINT - EAST ELEVATION SOUTH DOOR AND GRADE TO WINDOW SILL LEVEL WALLS. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
PARAPET & COPING | FRONT PARAPET WALL SEVERALLY LEANING INWARD. ALL VERTICAL COLUMN HOLDING THE PARAPET WALLS ARE OUT OF PLUMB. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | ROTTED WOOD CLADDING - EAST ELEVATION. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT WALL BOWED 45'. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | ENGINEERING REPORT REQUIRED. | 6816 N CLARK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / ENTIRE EXTERIOR WALL - SEVERELY OUT OF PLUMB AND LEANING OUTWARDS OVER PUBLIC ALLEY. PLANS AND PERMIT REQUIRED FOR EXTERIOR WALL RECONSTRUCTION. DANGEROUS AND HAZARDOUS CONDITIONS. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | WEST ELEVATION / MIDDLE OF BUILDING / CHIMNEY CAP - MISSING. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
CHIMNEY | WEST ELEVATION / MIDDLE OF BUILDING / CHIMNEY - BULGING AND SHIFTING MASONRY, WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION / MIDDLE OF THE BUILDING / 1ST FLOOR WINDOW GLASS PANE - SEVERELY CRACKED. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | MULTIPLE LOCATIONS / EXIT SIGNS - NOT ILLUMINATED. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
REPAIR ROOF STRUCTURE | MULTIPLE ROOF TRUSSES - BROKEN AND SOME MEMBERS CUT OUT AND REMOVED. SOME ROOF TRUSSES - SEVERELY OUT OF PLUMB AND LEANING. ENTIRE ROOF STRUCTURE WEAK AND UNSTABLE. MULTIPLE LOCATIONS - LARGE HOLES IN ROOF SHEATING. PLANS AND PERMIT REQUIRED FOR ROOF REPAIRS. DANGEROUS AND HAZARDOUS CONDITIONS. | 6816 N CLARK ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | HOLE ON WALL - INTERIOR WALL VIA EAST OVERHEAD DOOR FRAME. | 6816 N CLARK ST | COMPLAINT | FAILED | View |