Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 7:04 PM
PIN: 11324050220000
Property Address: 6460 N SHERIDAN RD
City - Zip: CHICAGO - 60626
2023 Property Class: EX
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75033
2023 Tax District: 75018
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 38 Violations
Violation Inspector Comments Address Category Status View
PROPER SIZE GRD ELECTRODE COND EXTENSION AMOUNT OF STORAGE IN CARDBOARD DIRECTLY IN FRONT OF TRANSFORMERS IN REAR HALLWAY D&H 6460 N SHERIDAN RD COMPLAINT PASSED View
ARRANGE COMPLETED PERMIT INSP. 100641867 6460 N SHERIDAN RD PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION OF TACO BELL SPACE THAT HAS ALREADY OPENED FOR BUSINESS WITHOUT ANY VENTILATION INSPECTIONS,HAVE STAMPED PLAN ON SITE AND PROVIDE ACCESS TO CEILINGS (PERMIT # 100641867) 6460 N SHERIDAN RD COMPLAINT FAILED View
14 GAUGE HOOD/STACK ABOVE ROOF HOOD EXHAUST TERMINATION OUTLET DOES NOT MEET CRITYRIA TO SIDE VENT RELOCATE HOOD EXHAUST OUTLET TO ABOVE REAR 1 STORY ROOF 18-28-506.3.13.1 6460 N SHERIDAN RD COMPLAINT FAILED View
PROVIDE PROVIDE HEATED MAKE UP AIR TO NEW TACO BELL HOOD AT THE RATE APPROX EQUAL TO HOOD EXH FAN CFM, 18-28-508.1 6460 N SHERIDAN RD COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT OBTAIN PERMIT TO CORRECT VIOLATIONS AND ADDITION OF MAKE UP SYSTEM IN TACO BELL SPACE 6460 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION 18-28-106.1 TACO BELL RESTAURANT BUILT WITHOUT ANY PERMITS 6460 N SHERIDAN RD COMPLAINT FAILED View
APPROVE PLANS ON SITE KEEP APPROVED PLANS ON SITE (13-40-090)(13-20-290) 6460 N SHERIDAN RD COMPLAINT FAILED View
14 GAUGE HOOD/STACK ABOVE ROOF KITCHEN EXHAUST INSTALLED INTO ALLEY (18-28-506.3.13.3) 6460 N SHERIDAN RD COMPLAINT FAILED View
14 GAUGE HOOD/STACK ABOVE ROOF 18-28-506.3.2 GREASE DUCT MATERIALS PROVIDE INDEPENDENT DUCT #14US GAUGE SHEET METAL FROM HOOD TO MECHANICAL VENTILATION EXHAUST SYSTEM TO DISCHARGE INDEPENDENTLY ABOVE ROOF-KITCHEN EXHAUST TERMINATING INTO ALLEY 6460 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED ARRANGE FOR COMPLETE PERMIT INSPECTION FOR VENTILATION SYSTEM WHEN WORK IS COMPLETE 6460 N SHERIDAN RD COMPLAINT FAILED View
STOP NUISANCE TO NEIGHBORS 7-28-00 NOTICE TO ABOVE 7-28-060 CONDITIONS DETRIMENTAL TO HEALTH PUBLIC NUISANCE VIOLATION 7-28-080 NUISANCE IN CONNECTION TO BUSINESS NEED TO ABATE EXCESSIVE GREASE BUILD UP IN ROOF REAR ALLEY 6460 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN MECH. VENT SYSTEM 18-28-102 APPLICABILITY MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE VENTILATION DURING HOURS OF OCCUPANCY NEED TO MAINTAIN KITCHEN EXHAUST SYSTEM MONTHLY TO ELIMINATE NUISANCE SMELLS 6460 N SHERIDAN RD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS DANGEROUS AND HAZARDOUS 14X-5-504.9 6460 N SHERIDAN RD COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS OUT DATED TAGS AND MISSING SIGNAGE DANGEROUS AND HAZARDOUS 14X-5-504.5 6460 N SHERIDAN RD COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY CORRIDOR EXCESSIVE STORAGE CAUSING OBSTRUCTION 24-26" DANGEROUS AND HAZARDOUS 26 14X-5-505.7.2 6460 N SHERIDAN RD COMPLAINT PASSED View
PROVIDE AISLES REDUCTION-CUP STATION AT CASHIER, DESK WITH CHAIR NEAR KITCHEN AREA, AND CORRIDOR DANGEROUS AND HAZARDOUS COMPROMISES FIRE SEPARATION 14X-3-303.13 6460 N SHERIDAN RD COMPLAINT PASSED View
REPAIR EXTERIOR DOOR DOOR TO INTERIOR CORRIDOR (REAR) DOOR OVERLAPS JAMB DOOR NOT CLOSING PROPERLY DANGEROUS AND HAZARDOUS COMPROMISES 6460 N SHERIDAN RD COMPLAINT PASSED View
STOP STORING GARBAGE COMMON AREA TACO BELL'S GARBAGE OVERFLOWING WITH GARBAGE 14X3-307 6460 N SHERIDAN RD COMPLAINT PASSED View
STOP SMOKE, NOXIOUS ODORS COMMON AREA FOUL ODOR DUE TO TACO BELL'S GARBAGE AND GREASE TRAP 14X6-606.4 6460 N SHERIDAN RD COMPLAINT PASSED View
PROVIDE PROVIDE ACCESS TO CEILING FOR FULL INSPECTION 2-22-020/2-22-040 6460 N SHERIDAN RD COMPLAINT PASSED View
DEFECTIVE OUTLETS REAR HALLWAY CONVENIENCE OUTLET DAMAGED AND HANGING OUT FROM DRYWALL D&H 6460 N SHERIDAN RD COMPLAINT PASSED View
SUPPORT FIXTURES REPLACE GLOBE ON HANGING FIXTURE OVER TABLE IN DINING AREA 6460 N SHERIDAN RD COMPLAINT PASSED View
RESTORE EXIT AND EM REPLACE PLASTIC EXIT SIGN IN REAR HALLWAY NEAR TRANSFORMER, REPLACE ALL PLASTIC EM LIGHT FIXTURES THROUGHOUT ENTIRE STORE REPAIR ALL OTHER INOPERABLE EXIT SIGNS AT REAR HALLWAY D&H 6460 N SHERIDAN RD COMPLAINT PASSED View
EXPOSED WIRING PLASTIC EXIT SIGN IN REAR HALLWAY HANGING BY WIRES, AND CONDUIT FOR CASH WRAP CASHIER STATION SEPARATED WITH CLASS L WIRING EXPOSED D&H 6460 N SHERIDAN RD COMPLAINT PASSED View
CONTINUITY OF RACEWAYS FLEX TO CONDUIT TRANSITION AT CASHIER STATION SEPARATED D&H 6460 N SHERIDAN RD COMPLAINT PASSED View
APPLIANCE INSIGHT DISCONNECT MUST HAVE DISCONNECT SWITCH FOR ICE MAKER IN DINING AREA 6460 N SHERIDAN RD COMPLAINT PASSED View
INSTALL GFCI'S ALL RECEPTACLES IN KITCHEN AND FOOD PREP AREAS MUST BE GFI PROTECTED 14E-2-210.8 (B) 6460 N SHERIDAN RD COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT ALL VIOLATIONS 14A-4-404.6 6460 N SHERIDAN RD COMPLAINT PASSED View
PROVIDE UNSANITARY CONDITIONS BEHIND COUNTER, IN FOOD PREP REAR AND THROUGHOUT RESTAURANT 7-28-060 6460 N SHERIDAN RD COMPLAINT PASSED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED ARRANGE FOR COMPLETE PERMIT INSPECTIONS FOR VENTILATION SYSTEMS WHEN WORK IS COMPLETE 6460 N SHERIDAN RD COMPLAINT FAILED View
14 GAUGE HOOD/STACK ABOVE ROOF 18-28-506.3.2 GREASE DUCT MATERIALS PROVIDE INDEPENDENT DUCT OF #14 US GAUGE SHEET METAL FROM HOOD TO MECHANICAL VENTILATING EXHAUST SYSTEM TO DISCHARGE INDEPENDENTLY ABOVE ROOF - KITCHEN EXHAUST TERMINATING INTO ALLEY 6460 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN MECH. VENT SYSTEM 18-28-102 APPLICABILITY - MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE VENTILATION DURING HOURS OF OCCUPANCY - NEED TO MAINTAIN KITCHEN EXHAUST SYSTEM MONTHLY TO ELIMINATE NUISANCE SMELLS. 6460 N SHERIDAN RD COMPLAINT FAILED View
STOP NUISANCE TO NEIGHBORS 7-28-010 NOTICE TO ABOVE / 7-28-060 - CONDITIONS DETRIMENTAL TO HEALTH - PUBLIC NUISANCE VIOLATION / 7-28-080 - NUISANCE IN CONNECTION TO BUSINESS - NEED TO ABATE EXCESSIVE GREASE BUILD UP IN REAR ALLEY. 6460 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 6460 N SHERIDAN RD PERMIT FAILED View
OPEN TYPE VIOLATION (VT 2021) FOLLOW APPROVED PLANS OR SUBMIT REVISED PLANS (13-32-120,130) (13-32-290) 6460 N SHERIDAN RD COMPLAINT FAILED View
NO PERMIT FLAT SIGN 1 BLDG MOUNTED FLAT 18' X 2' CHANNEL LETTER SIGN READS: "TACO BELL WITH LOGO" 6460 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 6460 N SHERIDAN RD PERMIT FAILED View