Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:31 PM
PIN: 20031100200000
Property Address: 4026 S CALUMET AVE
City - Zip: CHICAGO - 60653
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70118
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 26 Violations
Violation Inspector Comments Address Category Status View
REPAIR INTERIOR WALLS/CEILING 4028 S CALUMET 2ND FLOOR APARTMENT PLASTER FALLING OFF CEILING IN FRONT KITCHEN AND BATHROOM 4026 S CALUMET AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 4028 2ND FLOOR MISSING SMOKE DETECTORS 4026 S CALUMET AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 4028 2ND FLOOR MISSING SMOKE DETECTOR 4026 S CALUMET AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST OWNER OR MANAGEMENT SIGN ON FRONT WITH PHONE # 4026 S CALUMET AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING NO OWNERS I.D. SIGN POSTED 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRS GRADE TO 1ST FLOOR MISSING HANDRAILS 4026 S CALUMET AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION PARAPET WASHED OUT MORTAR (MINOR) 4026 S CALUMET AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE FRONT ENTRY DOORS TO UNITS MISSING DOOR VIEWERS 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR PORCH LEDGERS MISSING BOLTS, 2X6 JOIST SPAN 7'6" - RIM JOIST ARE SINGLE, 2X10 MISSING BOLTS AT COLUMNS, RAILS ARE 38" HIGH - MISSING SIMPSON CLIPS AND CENTER SUPPORTS AT 8 FOOT SPAN. SUPPORTS AT MASONRY WALL MISSING BOLTS, NEWELS. POST ARE MISSING BOLTS, RAILINGS ARE LOOSE AND PULLING. STAIR RISERS ARE UNEVENT WITH A 5" RISE AND 8" RISE WITH POPPING NAILS. DECKING HAS POPPING NAILS THROUGH OUT. PLANS AND PERMITS ARE REQUIRED FOR REPAIRS OR REPLACEMENT OF REAR PORCH SYSTEM. 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR PORCH LEDGERS MISSING BOLTS, 2X6 JOIST SPAN 7'6" - RIM JOIST ARE SINGLE, 2X10 MISSING BOLTS AT COLUMNS, RAILS ARE 38" HIGH - MISSING SIMPSON CLIPS AND CENTER SUPPORTS AT 8 FOOT SPAN. SUPPORTS AT MASONRY WALL MISSING BOLTS, NEWELS. POST ARE MISSING BOLTS, RAILINGS ARE LOOSE AND PULLING. STAIR RISERS ARE UNEVENT WITH A 5" RISE AND 8" RISE WITH POPPING NAILS. DECKING HAS POPPING NAILS THROUGH OUT. PLANS AND PERMITS ARE REQUIRED FOR REPAIRS OR REPLACEMENT OF REAR PORCH SYSTEM. 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM BUILDING REAR 3 STORY DOUBLE WIDE PORCH COLUMNS DOBLE CUT FOR RIM JOSITS AND BEAMS. LEDGER BOARDS WITH INSUFFICIENT BOLTS. GUARD RAILS ARE ONLY 36" IN HEIGHT SPANNING 12' WITH NO CENTER SUPPORTS. OUTSIDE SINGLE 2X10" BEAMS SPANNING 12' HAVE A DOWNWARD BOW ON THEM, ATTACHED TO COLUMNS WITH NAILS ONLY. 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS. PLANS AND PERMIT FOR REPAIRS. 4026 S CALUMET AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNERS ID SIGN NOT POSTED. 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR DOWNSPOUT REAR PORCH DOWNSPOUT MISSING SECTION BY GROUND LEVEL. 4026 S CALUMET AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE REAR PORCH - STORING BBQ GRILLS. APT 1N AT LIVING ROOM - STORIN CAR TIRES. 4026 S CALUMET AVE COMPLAINT FAILED View
REPAIR FLOOR APT 1N / HARDWOOD FLOORING - BUCKLED. KITCHEN FLOOR - DAMAGED AND MISSING VINYL FLOORING. 4026 S CALUMET AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER APT 1N / BATHROOM CEILING AND WALL BY TOILET - UNFINSHED DRYWALL REPAIRS. 4026 S CALUMET AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY APT 1N REAR EXIT DOOR - BURGLAR GATE. 4026 S CALUMET AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF MOST APTS. - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. 4026 S CALUMET AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR 4026 S CALUMET AVE COMPLAINT PASSED View
FILE BLDG REGISTRATION BUILDING HAS NEVER BEEN REGISTERED 4026 S CALUMET AVE COMPLAINT PASSED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING ¿ NO RESPONSE. UNABLE TO VERIFY DETECTORS, AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY. NO YARD GATE TO REAR ELEVATION. UNABLE TO INSPECT REAR PORCHES. 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR LINTELS FRONT ELEVATION /METAL WINDOW LINTELS - RUSTED, BENT, SAGGING, WITH GAPS ABOVE IT.PERMIT REQUIRED TO REPLACE. 4026 S CALUMET AVE PERIODIC FAILED View
PARAPET NORTH ELEVATION /PARAPET WALL - WASHED OUT MORTAR.EAST ELEVATION /PARAPET WALL - FRACTURED, PARGED WASHED OUT MORTAR, WITH SECTIONS - MISIING. 4026 S CALUMET AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR. 4026 S CALUMET AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING. 4026 S CALUMET AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION ARRANGE FOR INTERIOR INSPECTION 4026 S CALUMET AVE COMPLAINT FAILED View