Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | ALL REAR EXTERIOR STAIR SYSTEMS-6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLABS. FOUNDATION STATUS UNKNOWN. 4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET HIGH. 4X4 COLUMNS WITH BUTT JOINT OR WITH NO BOLTS USED AT LAP JOINTS. STRINGER INADEQUATELY SUPPORTED, 2X8 JOIST OVER SPANNED. MISSING JOIST HANGERS, GUARD RAILS TOO LOW. PLANS AND PERMIT REQUIRED | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
CARPETING | COURT YARD INTERIOR STAIRWELLS LOOSE & TORN CARPET SOME AREA'S DIRTY. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST & WEST GRADE TO BASEMENT STAIRWELLS MISSING HANDRAILS. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENT TO VERIFY DETECTORS AND ABLE TO ACCESS PORCHES. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FOR 2013. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
PIGEONS-UNSANITARY HOUSING | 1347 W - WEST PORCH AT 3RD - PIGEON FOULING. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 1349 W AND 1349 W - 1345 1 / 2 W - WEST PORCHES AT 3RD - EXCESSIVE ACCUMULATION OF PERSONAL ITEMS , BIKES , FURNITURE , JUNK AND DEBRIS. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | BASEMENT BOILER ROOM - CEILING - OPEN HOLES WITH MISSING PLASTER / DRYWALL - EXPOSED WOOD LATH. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1349 W - FRONT INTERIOR STAIRWAY AT 3RD - GUARDRAIL WITH BALUSTER MISSING. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
STOP LEAKING WATER | APARTMENT 1349 W - 3 SOUTH - KITCHEN FAUCET LEAK. 1347 1 / 2 W - 1 SOUTH - BATH TUB FAUCET LEAK. 1347 1 / 2 W - 2 NORTH AND 2 SOUTH - KITCHEN FAUCETS - LEAKING. 1347 1 / 2 W - 3 NORTH BATH TUB FAUCET LEAK. 1345 1 / 2 W - 2 WEST TUB FAUCET LEAK. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE FAUCET | 1345 1 / 2 W - 2 WEST - KITCHEN FAUCET - LOOSE AND BROKEN HANDLE. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | 1347 W - 3 NORTH - FRONT ENTRY DOOR THRESHOLD - LOOSE. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 1341 W - 2 SOUTH - BATHROOM CEILING - MILDEWED AND UNSANITARY CONDITIONS. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 1347 1 / 2 W - 1 SOUTH - BATHROOM THRESHOLD AND HALL FLOOR - LOOSE AND BUCKLED WOOD SECTIONS. 1343 W - 2 SOUTH - KITCHEN FLOOR - BROKEN , LOOSE , AND MISSING FLOOR TILES. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS , BASEMENT WINDOWS PLYWOOD BOARDED . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - POSTED OWNER'S I.D. SIGN INCOMPLETE INFORMATION . MISSING COMPLETE MAILING ADDRESS . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | ALL FRONT ENTRY DOORS AND FRAMES , ROTTED WITH WORN FINISH . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS , BASEMENT WINDOW SASHES ROTTED WITH FLAKING PAINT AND PUTTY . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH AT EAST AND WEST FRONT BASEMENT AREAWAY STAIRS MISSING HANDRAILS . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | NINE OPEN REAR PORCH ROOFS , AREAS OF DECKING AND RAFTERS ROTTED WITH FLAKING PAINT . DECKING SUBSTANDARD REPAIRS WITH PLYWOOD SCAB SCREWED TO UNDERSIDE . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | NORTHWEST BASEMENT AREAWAY , WATER LEAKING FROM CEILING . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTHWEST BASEMENT AREAWAY IRON GATE , BROKEN LOCK KNOB . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | SOUTHEAST BASEMENT BOILER ROOM STOCKPILED WITH JUNK AND DEBRIS . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NINE THREE STORY WOOD PAINTED PORCHES HAVE BEEN SCABBED WITH TREATED LUMBER MATERIALS , WITH SUBSTANDARD REPAIRS AND CONNECTIONS AND REQUIRE REPLACEMENTS WITH PLANS AND PERMITS . ALL PORCHES HAVE THE SAME AND SIMILAR DEFECTS . UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SCABBED ( DOUBLE UPRIGHT ) ONTO UNDERSIZED FOUNDATIONS WITH TWO UPRIGHTS SET ON ONE METAL BASE . NO SUPPORT FOR STRUCTURE . UPRIGHTS SCABBED TO OLD DETERIORATED COLUMNS WITH UNDERSIZED LAP JOINTS WITH ONLY TWO BOLTS . ALL PAINTED LUMBER AREAS ROTTED WITH FLAKING PAINT . ROTTED FLOOR JOIST AND DECKING WORN AND LOOSE . TREADS ONLY NINE INCHES WIDE WITH NO STAIR HEADER SUPPORT . WINDERS STAIRS WEAK WITH NO SUPPORT , ONLY NAILED WITH TWO BY FOURS SCABBED TO UNDERSIDE OF TREADS WITH ONLY NAILS FOR SUPPORT . GUARDRAILS WEAK AND OVERSPANNED . STAIR GAPS OVER SIX INCH MAXIMUM FROM TOP OF TREAD TO GUARDRAIL BASE. STAIR STRINGER CRACKED IN AREAS OF TREAD REPLACEMENT . | 1341 W TOUHY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | NORTH/#1347 1/2 FOYER - CRACKED PLASTER AT CEILING | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH - EXTERIOR WALL - WASHED OUT MORTAR | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH - THRU-CORRIDOR - CRACKED CONCRETE TREADS AT NE CORNER | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1345W /APT.2N - HALLWAY CEILING - BUBBLE PAINT. 1349W /APT.1S - BEDROOM CEILING - WATER STAIN[MINOR]1341W /APT.3N - HALLWAY CEILING - NEEDS PAINT OVER RECENTLY PATCH REPAIR. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION /EXTERIOR WALL - SPALLED BRICKS, WITH WASHED OUT MORTAR. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 1345 1/2 REAR PORCH AT 1 AND 3 ROTTEN DESK AND JOIST. REAR PORCHES IMPROPER FOUNDATION, ARCHOR LEDGES, STRINGERS NO JOIST HANGERS, 4"X4" COLUMNS, RAILS 33 ROTTEN DECKING. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMIT AND PLANS TO REPAIR PORCH. | 1341 W TOUHY AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | WEST AT SOUTH AT GRADE OPEN MORTAR JOINTS. | 1341 W TOUHY AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AND EAST PORCHES. | 1341 W TOUHY AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | 1345 1/2 REAR PORCH AT 1 AND 3 ROTTEN DESK AND JOIST. REAR PORCHES IMPUOPES FOUNDATION, ARCHOR LEDGES, STRINGERS NO JOIST HANGERS, 4"X4" COLUMNS, RAILS 33 ROTTEN DECKING. | 1341 W TOUHY AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, REAR PORCHES, AND SPECIFICALLY APT. #1347 1/2-1N OR 1S FOR COMPLAINT OF ROACHES. UNVERIFIED DETECTORS AND CONDITIONS. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | 1341 NORTH STAIR GRADE TO BASEMENT CRACKED CONCRETE. | 1341 W TOUHY AVE | PERIODIC | PASSED | View |
REPLACE DEFECTIVE FLUSH DEVICE | 1345 1 / 2 W - 2 EAST - BATHROOM TOILET FLUSH VALVE - BROKEN. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
INSTALL COVERS | 1347 W - 3 NORTH - BATHROOM ON WALL - ELECTRICAL OUTLET COVER - MISSING. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | BASEMENT BOILER ROOM - CEILING AND WALL - OPEN ELECTRICAL JUNCTION BOXES. | 1341 W TOUHY AVE | PERIODIC | FAILED | View |