Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING- NO OWNER'S ID SIGN POSTED. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL,NORTH ELEVATION,SPALLED BRICKS AND WASHED OUT MORTAR. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED STAIRWAY, AND APT.3 -MISSING SMOKE DETECTORS. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APT.#3- MISSING CARBON MONOXIDE DETECTOR. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT APARTMENT-NO RESPONSE,UNVERIFIED DETECTORS. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION- EXTERIOR MASONRY WALL AT THIRD FLOOR,FRACTURED MASONRY AND WASHED OUT MORTAR. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO ENTRY TO BASEMENT,FIRST FLOOR AND SECOND FLOOR APARTMENTS. UNVERIFIED DETECTORS AND CONDITIONS. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES, INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN BASEMENT WITHOUT PERMIT. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORGINIAL STATE. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED THREE STORY WOOD PORCH - IMPROPER CONNECTIONS THROUGHOUT ENTIRE PORCH, 4X4 COLUMNS STACKED AND AT BASEMENT LEVEL ROTTING AT CONNECTION POINT, BEAMS AND JOISTS NOT TIED BACK TO WALLS INSIDE BEAM POCKETS MISSING STRAPS, STRINGERS UPPER ENDS INADEQUATELY SUPPORTED AT HEADER JOISTS AND NOT BOLTED TO BUILDING STRUCTURE GAPS, TREADS DAMAGED AND CRACKED BETWEEN FIRST AND SECOND FLOOR DANGEROUS AND HAZARDOUS, DECKING WORN, RAILINGS SHORT, ENCLOSED PORCH DRYWALL WATER DAMAGED. PLANS AND PERMIT REQUIRED TO REPLACE DANGEROUS AND HAZARDOUS REAR ENCLOSED PORCH. | 5640 N SPAULDING AVE | COMPLAINT | FAILED | View |