Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | 6647 1/2 UNIT 2W SMOKE DETECTOR NOT OPERATING 6647 1/2 UNIT 1E SMOKE DETECTOR NOT OPERATING 6647 1/2 UNIT 3W SMOKE DETECTOR NOT OPERATING | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View | |
STOP LEAKING WATER | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View | |
STOP ODORS RPR DFT SEWAGE SYS | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View | |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED FROM 1990 THRU 2006 AND 2009 | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST REAR PORCH-(1) 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB OR ON CONCRETE BLOCKS ON TOP OF CONCRETE SLAB (2) FOUNDATION STATUS UNKNOWN (3) 6X6 AND 4X4 COLUMNS OVER NOTCHED (4) LAP JOINTS ON COLUMNS WITH GAPS AND ONLY 2 BOLTS (5) INADEQUATE BEAM TO COLUMN CONNECTION (6) MISSING TIE STRAPS (7) 2X8 JOIST OVER SPANNED (8) STRINGERS INADEQUATELY SUPPORTED (9) STAIR TREADS TOO SMALL (10) GUARDRAILS TOO LOW (11) PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIRWAY-(1) 4X4 CENTER SUPPORT COLUMN OVER 2 FEET HIGH AND RESTING ON A HANDRAIL-DOES NOT REST ON FOUNDATION (2) WOOD ROTTED THRU-OUT (3) STRINGERS INADEQUATELY SUPPORTED (4) STAIR TREADS TOO SMALL (5) GUARDRAILS TOO LOW (6) MISSING HANDRAIL TO BASEMENT EAST STAIRS TO BASEMENT- (1) FRACTURED CONCRETE (2) MISSING HANDRAIL (3) MISSING GUARDRAILS-PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALK-FRACTURED AND MISSING SECTION OF CONCRETE | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED FROM 1990 THRU 2006 AND 2009 | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | PORCHES-(SOUTH)LEDGERS ARE ONLY NAILED INTO THE BUILDING CONNECTIONS. DECK JOISTS ARE ONLY TOE NAILED INTO THE LEDGERS. STRINGERS ARE ONLY TOE NAILED AT COLUMN / POST CONNECTIONS. WINDER STRINGERS ARE ONLY TOE NAILED INTO ROTTED, UPRIGHT 2X4 MEMBER, THAT IS ONLY NAILED INTO TO THE BUILDING. ROTTED, LOOSE WINDER STRINGER FROM (G) TO MID-LANDING. BROKEN HANDRAIL FROM (G) TO MID-LANDING. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. (EAST) COLUMNS ARE SEPERATING AT THE BEAM CONNECTIONS; NOTICEABLE GAPS. COLUMNS ARE TWISTED AT THE SPLICES; NOTICEABLE GAPS; ONLY TWO BOLTS. 2X8 BEAMS ARE ONLY NAILED INTO THE COLUMN / POST CONNECTIONS. STRINGERS ARE ONLY NAILED AT THE COLUMN / POST CONNECTIONS. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. MISSING VEHICULAR IMPACT PROTECTION. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIRWAY-(1) 4X4 CENTER SUPPORT COLUMN OVER 2 FEET HIGH AND RESTING ON A HANDRAIL-DOES NOT REST ON FOUNDATION (2) WOOD ROTTED THRU-OUT (3) STRINGERS INADEQUATELY SUPPORTED (4) STAIR TREADS TOO SMALL (5) GUARDRAILS TOO LOW (6) MISSING HANDRAIL TO BASEMENT EAST STAIRS TO BASEMENT- (1) FRACTURED CONCRETE (2) MISSING HANDRAIL (3) MISSING GUARDRAILS-PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALK-FRACTURED AND MISSING SECTION OF CONCRETE | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST REAR PORCH-(1) 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB OR ON CONCRETE BLOCKS ON TOP OF CONCRETE SLAB (2) FOUNDATION STATUS UNKNOWN (3) 6X6 AND 4X4 COLUMNS OVER NOTCHED (4) LAP JOINTS ON COLUMNS WITH GAPS AND ONLY 2 BOLTS (5) INADEQUATE BEAM TO COLUMN CONNECTION (6) MISSING TIE STRAPS (7) 2X8 JOIST OVER SPANNED (8) STRINGERS INADEQUATELY SUPPORTED (9) STAIR TREADS TOO SMALL (10) GUARDRAILS TOO LOW (11) PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | MISSING GUARDRAIL AT GRADE LEVEL. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR GUTTER | GUTTER-RUSTED THRU; HOLES; LEAKING WATER. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES-BROKEN. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND CONDITIONS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-MISSING A MAILING ADDRESS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | CALL (312) 743-0413 | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PORCHES-(SOUTH)LEDGERS ARE ONLY NAILED INTO THE BUILDING CONNECTIONS. DECK JOISTS ARE ONLY TOE NAILED INTO THE LEDGERS. STRINGERS ARE ONLY TOE NAILED AT COLUMN / POST CONNECTIONS. WINDER STRINGERS ARE ONLY TOE NAILED INTO ROTTED, UPRIGHT 2X4 MEMBER, THAT IS ONLY NAILED INTO TO THE BUILDING. ROTTED, LOOSE WINDER STRINGER FROM (G) TO MID-LANDING. BROKEN HANDRAIL FROM (G) TO MID-LANDING. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. (EAST) COLUMNS ARE SEPERATING AT THE BEAM CONNECTIONS; NOTICEABLE GAPS. COLUMNS ARE TWISTED AT THE SPLICES; NOTICEABLE GAPS; ONLY TWO BOLTS. 2X8 BEAMS ARE ONLY NAILED INTO THE COLUMN / POST CONNECTIONS. STRINGERS ARE ONLY NAILED AT THE COLUMN / POST CONNECTIONS. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. MISSING VEHICULAR IMPACT PROTECTION. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIRWAY-(1) 4X4 CENTER SUPPORT COLUMN OVER 2 FEET HIGH AND RESTING ON A HANDRAIL-DOES NOT REST ON FOUNDATION (2) WOOD ROTTED THRU-OUT (3) STRINGERS INADEQUATELY SUPPORTED (4) STAIR TREADS TOO SMALL (5) GUARDRAILS TOO LOW (6) MISSING HANDRAIL TO BASEMENT EAST STAIRS TO BASEMENT- (1) FRACTURED CONCRETE (2) MISSING HANDRAIL (3) MISSING GUARDRAILS-PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | MISSING GUARDRAIL AT GRADE LEVEL. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR GUTTER | GUTTER-RUSTED THRU; HOLES; LEAKING WATER. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | EXTERIOR WOOD PORCH SYSTEMS PERNIT # 100351836 ISSUE DATE 9.30.2010 ARRANGE FOR INSPECTION PORCH FINALS WITH ORIGINAL PLANS PLANS AND PERMIT ON SITE. | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2 NEW EXTERIOR REAR WOOD PORCH SYSTEMS FAIL INSPECTIONS, AND INCOMPLETE. PLANS AND PERMIT PULLED BUT NOT ON SITE. THESE 2 PORCHES WERE POORLY BUILT. 6647 1/2 AND 6647 HAS SIMILAR IF NOT SAME DEFICIENT MEMBERS. FOUNDATION NOT VERIFIED; BEAMS OPEN POCKETS AT BRICK, NO SUPPORT AT BRICKS, DANGEROUS; LEDGERS LIGHT GAGE METAL BRACKETS AND TOE NAILED CONNECTIONS; STAIRS UNEVEN RISER HEIGHTS AND DEPTHS OF TREADS VARY FROM 9 1/4 TO 10 1/2, AND HEIGHTS 7 1/4- 9 1/4, NOSING UNDER SIZED AT WINDERS; PORCHES ARE UNSAFE. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
TELEPHONE, DATA AND COMMUNICAT | EXTERIOR PHONE, DATA, CABLE WIRES NOT SECURE, HANGING, LOOSE, MORE SO AT REAR. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | INTERIOR FRONT STAIR WELLS, FIRE EXSTINGUISHERS OUT DATED TAGS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | PORCHES-(SOUTH)LEDGERS ARE ONLY NAILED INTO THE BUILDING CONNECTIONS. DECK JOISTS ARE ONLY TOE NAILED INTO THE LEDGERS. STRINGERS ARE ONLY TOE NAILED AT COLUMN / POST CONNECTIONS. WINDER STRINGERS ARE ONLY TOE NAILED INTO ROTTED, UPRIGHT 2X4 MEMBER, THAT IS ONLY NAILED INTO TO THE BUILDING. ROTTED, LOOSE WINDER STRINGER FROM (G) TO MID-LANDING. BROKEN HANDRAIL FROM (G) TO MID-LANDING. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. (EAST) COLUMNS ARE SEPERATING AT THE BEAM CONNECTIONS; NOTICEABLE GAPS. COLUMNS ARE TWISTED AT THE SPLICES; NOTICEABLE GAPS; ONLY TWO BOLTS. 2X8 BEAMS ARE ONLY NAILED INTO THE COLUMN / POST CONNECTIONS. STRINGERS ARE ONLY NAILED AT THE COLUMN / POST CONNECTIONS. MOST MEMBERS ARE ONLY TOE NAILED AT THE CONNECTIONS. MISSING VEHICULAR IMPACT PROTECTION. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIRWAY-(1) 4X4 CENTER SUPPORT COLUMN OVER 2 FEET HIGH AND RESTING ON A HANDRAIL-DOES NOT REST ON FOUNDATION (2) WOOD ROTTED THRU-OUT (3) STRINGERS INADEQUATELY SUPPORTED (4) STAIR TREADS TOO SMALL (5) GUARDRAILS TOO LOW (6) MISSING HANDRAIL TO BASEMENT EAST STAIRS TO BASEMENT- (1) FRACTURED CONCRETE (2) MISSING HANDRAIL (3) MISSING GUARDRAILS-PLANS AND PERMIT REQUIRED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2 NEW EXTERIOR REAR WOOD PORCH SYSTEMS FAIL INSPECTIONS, AND INCOMPLETE. PLANS AND PERMIT PULLED BUT NOT ON SITE. THESE 2 PORCHES WERE POORLY BUILT. 6647 1/2 AND 6647 HAS SIMILAR IF NOT SAME DEFICIENT MEMBERS. FOUNDATION NOT VERIFIED; BEAMS OPEN POCKETS AT BRICK, NO SUPPORT AT BRICKS, DANGEROUS; LEDGERS LIGHT GAGE METAL BRACKETS AND TOE NAILED CONNECTIONS; STAIRS UNEVEN RISER HEIGHTS AND DEPTHS OF TREADS VARY FROM 9 1/4 TO 10 1/2, AND HEIGHTS 7 1/4- 9 1/4, NOSING UNDER SIZED AT WINDERS; PORCHES ARE UNSAFE. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | EXTERIOR VARIOUS LOCATIONS TORN SCREENS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
FOLLOW APPROVED PLANS | REAR PORCH- OUTSIDE BEAMS NOT IN MASONRY POCKETS, BUT ARE ANCHORED TO JOIST SERVING AS LEDGER. BEAM CONNECTION IS MADE WITH L90 TIES ONLY AT BOTH LEDGER AND COLUMN. AT CENTER COLUMN BEAM CONNECTION MADE WITH BOLTS, BOLTS ARE MISSING NUTS. SOUTH EAST AND NORTH EAST STRINGERS CONNECTED/ ANCHORED TO COLUMNS WITH NAILS AND/ OR SCREWS ONLY. DEFLECTING RAILS. PORCH NOT BUILT ACCORDING TO APPROVED PLAN. BUILD/ REPAIR/ CORRECT PORCH ACCORDING TO PLAN. ARRANGE FOR FINAL INSPECTION AND HAVE APPROVED PLAN AND ORIGINAL PERMIT ON SITE AT TIME OF INSPECTION. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 6647 1/2 2W AND 2E- NO SMOKE DETECTORS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | 6647 1/2 3E WATER DAMAGE, FLAKING PAINT ON LIVING ROOM CEILING. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | LIMITED INTERIOR ACCESS. NO ENTRY BASEMENT. NO ACCESS SOUTH EXTERIOR PORCH. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AND SIDE PORCH SYSTEM-ARRANGE FOR INSPECTION | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
CARPETING | CARPETING IN STAIRWAY G-3 WEST ENTRANCE | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | PEEPHOLE MISSING 1ST W | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM-RAILS ARE 39", 4X4 NOT BOLTED , NO METAL TIES ON LOOKOUTS, STRINGERS NOT BOLTED | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR PORCH REPAIR | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
PIGEONS-NESTING | PIGEON NUISANCE AT REAR PORCH STRAY PIGEONS | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WALL/BRICK DETERIORATE AT 2ND FLR REAR AT RAIL MEETS WALL | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | WEST EXTERIOR STAIRWAY/2ND FLOOR-BROKEN LIGHT FIXTURE WITH EXPOSED WIRES | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | WEST EXTERIOR STAIRWAY/2ND FLOOR-BROKEN LIGHT FIXTURE WITH EXPOSED WIRES | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | MISSING HANDRAIL. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS AND CONDITIONS. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | MISSING HANDRAIL. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
RESET LOOSE FIXTURE | TOLIET IN BASEMENT APARTMENT. | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | FROM CEILING IN BASEMENT APARTMENT BATHROOM. | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT AND FIRST FLOOR APARTMENTS. | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 6647 N GREENVIEW AVE | COMPLAINT | FAILED | View | |
REPAIR INTERIOR WALLS/CEILING | 6647N/APT. #G-BATHROOM-WATER DAMAGED CEILING DUE TO LEAK FROM FIRST FLOOR UNIT. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- MOST APARTMENTS,NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED DETECTORS FOR 2022 ANNUAL INSPECTION. | 6647 N GREENVIEW AVE | PERIODIC | FAILED | View |