The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO MOST DWELLING UNITS TO VERIFY DETECTORS | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | APT. 3N, 6460: NO CARBON MONOXIDE DETECTOR | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES: CONDITIONS TYPICAL ON BOTH-RAILINGS TOO LOW, ONLY 30" HIGH, STRINGERS NOT BOLTED, IMPROPER BEAM TO COLUMN CONNECTION, 2X4 COLUMNS USED TO SUPPORT STAIR STRINGER, WOOD ROTTED THROUGHOUT, NO JOIST HANGERS, NO BOLTS OBN LEDGER; PLANS AND PERMITS REQUIRED | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOWS IN BASEMENT-EAST ELEVATION | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEV 6458 BSMT. WINDOWS GLASS BLOCK BROKEN AND OPEN. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2009. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS OR PERMIT ON FILE TO COVERT TO CONSO'S PERMIT #100150150 HAS BEEN REVOKED. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | 2331-33 FRONT STAIRWAY MISSING FIRE EXTINGUISHERS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | 6458-60 FRONT STAIRWAY FIRE EXTINGUISHERS - DISCHARGED OR MISSING TAGS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | 6458-60 AT GRADE AND 2ND FLOOR EXPOSED WIRES. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 6458-60 FRONT STAIRWAY CEILING WATER DAMAGED DRYWALL. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | 6458-60 FRONT STAIRWAY SKYLIGHT BROKEN GLASS PANES | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQUIRED | 2333 BASEMENT DWELLING UNIT UNFINISHED DWELLING UNIT,EXPOSED STUDS THRU OUT UNIT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | 2333 BASEMENT DWELLING UNIT AND LAUNDRY ROOM / CEILING EXPOSED LATHE AND FLOOR JOIST. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | BASEMENT LAUNDRY ROOM AT ELECTRICAL METER DANGEROUS CONDITIONS EXPOSED WIRES AT BREAKER BOX.WIRES JUMPED AND CROSSED. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES (CONDITIONS TYPICAL) (1) 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB WITH CONCRETE BOX POURED AROUND COLUMNS AT BASE.(2)FOUNDATION STATUS UNKNOWN.(3)LOOK OUT BEAMS OVER SPANNED.(4)STRINGERS INADEQUATELY SUPPORTED.(5)2X8 JOIST OVER SPANNED.(6)STAIR TREADS TOO SMALL.(7)GUARDRAILS TOO LOW.(8)PLANS AND PERMIT REQUIRED. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PIGEONS-UNSANITARY HOUSING | REAR PORCHES PIGEON FECES THRU-OUT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | REAR ENCLOSED PORTION OF PORCHES- NO FIRE RATING,EXPOSED WOOD ON INTERIOR SIDE. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCHES GANG GRAFFITI. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | ALL ENTRY DOORS WOLL NOT LOCK. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | 6458-60 AT GRADE AND 2ND FLOOR EXPOSED WIRES. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 2331-33 ENTRY DOOR MISSING GLASS PANE. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | EXPIRED FIRE EXTINGUISHERS FRON INTERIOR STAIRS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 6458-60 FRONT INTERIOR STAIR WITH WATER DAMAGED STAIR SOFFIT BEFORE 3, LOOSE AND FLAKING PLASTER. SKY LIGHT WITH LOOSE AND FALLING DRY WALL AND WATER DAMAGE. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PIGEONS-UNSANITARY HOUSING | REAR PORCHES- PIGEON WASTE THROUGHOUT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR SOUTH EAST PORCH- RAILS ARE 34 1/2'' IN HEIGHT. ROTTING RAILS, LOOSE AND DEFLECTING, ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY AT 6X6 COLUMN CONNECTIONS. NUMEROUS STRINGER CONNECTIONS MADE WITH NAILS ONLY. WINDER / STRINGER COLUMN IN 4X4 AND EXTENDS OVER 20' AND IS NOT CONTINUOS TO GROUND BUT IS SUPPORTED FROM 1RST TO 3RD BY STRINGER AT 1. ROTTING RIM JOITS AT 2. LEDGER BOLTS SPACE AS FAR APART AS 36''. JOISTS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 11''. WORN TREADS. OBTAIN COMPLETE PLAN AND PERMIT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR SOUTH WEST PORCH- DANGEROUS AND HAZARDOUS DUE TO SIGNIFICANT ROTTING JOISTS AND DECKING AT 2 AND BROKEN, LOOSE, ROTTING GUARD RAIL AT 3. 6X6 LOOKOUT BEAMS SPAN 7' 5''. 4X4 CENTER STRINGER COLUMN SPANS OVER 20'. STRINGERS, RAILS AND POSTS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. 36'' GUARD RAILS ROTTING AND SPAN 8' 6'' WITH NO INTERMEDIATE SUPPORT- LOOSE AND DEFLECTING. OBTAIN COMPLETE PLAN AND PERMIT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 6458-60 FRONT INTERIOR STAIR WITH WATER DAMAGED STAIR SOFFIT BEFORE 3, LOOSE AND FLAKING PLASTER. SKY LIGHT WITH LOOSE AND FALLING DRY WALL AND WATER DAMAGE. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR SOUTH EAST PORCH- RAILS ARE 34 1/2'' IN HEIGHT. ROTTING RAILS, LOOSE AND DEFLECTING, ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY AT 6X6 COLUMN CONNECTIONS. NUMEROUS STRINGER CONNECTIONS MADE WITH NAILS ONLY. WINDER / STRINGER COLUMN IN 4X4 AND EXTENDS OVER 20' AND IS NOT CONTINUOS TO GROUND BUT IS SUPPORTED FROM 1RST TO 3RD BY STRINGER AT 1. ROTTING RIM JOITS AT 2. LEDGER BOLTS SPACE AS FAR APART AS 36''. JOISTS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 11''. WORN TREADS. OBTAIN COMPLETE PLAN AND PERMIT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR SOUTH WEST PORCH- DANGEROUS AND HAZARDOUS DUE TO SIGNIFICANT ROTTING JOISTS AND DECKING AT 2 AND BROKEN, LOOSE, ROTTING GUARD RAIL AT 3. 6X6 LOOKOUT BEAMS SPAN 7' 5''. 4X4 CENTER STRINGER COLUMN SPANS OVER 20'. STRINGERS, RAILS AND POSTS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. 36'' GUARD RAILS ROTTING AND SPAN 8' 6'' WITH NO INTERMEDIATE SUPPORT- LOOSE AND DEFLECTING. OBTAIN COMPLETE PLAN AND PERMIT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PIGEONS-UNSANITARY HOUSING | REAR PORCHES- PIGEON WASTE THROUGHOUT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | ALL ELEVATRIONS/ SILLS- WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOWS THRUOUT- MISSING SCREENS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PARAPET | NORTH ELEVATION/ PARAPET WALL- FRACTURED MASONRY, WITH WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | NORTH AND WEST ELEVATIONS- WINDOW FRAMES- ROTTING, WITH PEELING PAINT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | EAST ELEVATION/ CORNICE- WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR ROOF | 2331W/ REAR EXTERIOR PORCH ROOF- ROTTING, LOOSE, AND HANGING DOWN SECTIONS OF SHEATHING. EXISTING ROOF TO REMAIN AS PER ARCHITECTS PLANS FOR PORCH REPLACEMENT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT MOST INTERIOR STAIRWAYS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR EXTERIOR MASONRY WALL-SOUTH -WEST ELEVATION SPALLED BRICKS AND WASHED OUT MORTAR, AT GRADE. | 6458 N CLAREMONT AVE | COMPLAINT | CLOSED | View |
REPAIR COPING | NORTH ELEVATION/ COPING STONEWORK- WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
PARAPET | NORTH ELEVATION/ PARAPET WALL- FRACTURED MASONRY, WITH WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR EXTERIOR MASONRY WALL-SOUTH -WEST ELEVATION SPALLED BRICKS AND WASHED OUT MORTAR, AT GRADE. | 6458 N CLAREMONT AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING REGISTERATION, NOT REGISTERED FROM 2009 THRU 2015. | 6458 N CLAREMONT AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINT NORTH ELEVATION EAST END OF BUILDING, WINDOWS AND TRIM, FLAKING PAINT BASEMENT WINDOWS NORTH ELVATION AND EAST ELEVATION WINDOWS. AT ARTHUR PORCHES PANTRY WINDOWS FLAKING PAINT. WEST ELEVATION EAST END FLAKING PAINT WINDOWS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES WHERE JOISTS ARE NOT IN MASONRY POCKETS BOLT LEDGERS AND INSTALL JOIST HANGERS. SECURE BEAM TO COLUMN CONNECTIONS, BOLT STRINGERS TO MASONRY. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION EAST END RUSTING LINTELS, FLAKING PAINT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | ARTHUR ENTRY DAMAGED PLASTER AT BOTTOM OF STAIRWELL AND WATER DAMAGED PLASTER - FLAKING PAINT AT SKY LIGHT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 2331-33 ENTRY DOOR MISSING GLASS PANE. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2009 TO PRESENT. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | EXPIRED FIRE EXTINGUISHERS FRON INTERIOR STAIRS. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 2331W/ REAR EXTERIOR WOODEN PORCH- CHARCOAL GRILL AT 1ST FLOOR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR COPING | NORTH ELEVATION/ COPING STONEWORK- WASHED OUT MORTAR. | 6458 N CLAREMONT AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. | 6458 N CLAREMONT AVE | COMPLAINT | FAILED | View |