Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REMOVE EXPOSED CABLE | UNAPPROVED NM CABLE (ROMEX) AT LOWER REAR INTERIOR STAIRS REMOVE WHERE REQUIRED | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR OF PROPERTY GARAGE FASCIA ROTTED REPAIRS REQUIRED (14X-3-303.1) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION AT EXTERIOR ENTRIES,GARAGE DOOR INTERIOR STAIRS AND WHERE REQUIRED | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
INTERIOR FINISH FIRERESISTANCE | MISSING SECTIONS OF 1HR FIRE SEPARATION ABOVE DROP CEILING IN BATHROOM (D&H) (14B-8-803.1.1) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH CHIMNEYS - SPALLED BRICKS OPEN MORTAR JOINTS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WOOD WINDOW SASHES - ROTTED WITH FLAKING PAINT AND PUTTY. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | REAR GUTTERS AND DOWNSPOUTS RUSTED WITH FLAKING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST WOOD WINDOW SILLS ROTTED WITH FLAKING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR GARAGE EAVES AND TRIM ROTTED WITH FLAKING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | NORTH SIDE OF GARAGE WOOD PILED | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
RATS | NORTH SIDE OF GARAGE RAT HOLES AND RAT HARBORAGE . | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH RUSTED WITH FLAKING PAINT HANDRAILS AND GUARDRAILS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - SPALLED BRICKS WITH OPEN MORTAR JOINTS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS ,TORN, LOOSE AND MISSING. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SIX FOOT HIGH CHAINLINK FENCE IN FRONT AND REAR YARD REQUIRES PERMIT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEYS (2)-ERODED MORTAR; OPEN JOINTS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALLS-LOOSE, ERODED MORTAR; OPEN JOINTS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES / SASHES-WORN; PEELING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | GUTTER / DOWNSPOUT-PEELING PAINT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS-ROTTED. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SECURITY GATE ATTACHED TO THE DOOR OPENING; PADLOCKED. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | CHAINLINK FENCE-6 FOOT HEIGHT; INSTALLED WITHOUT A PERMIT. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR DOOR-BROKEN GLASS PANEL. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR-MISSING. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR-MISSING. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST ELEVATION - GATE - CHAINED AND PADLOCKED. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION - FRONT STEPS - SPALLING AND BROKEN CONCRETE. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION - SILLS - WASHED OUT MORTAR. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR COPING | WEST ELEVATION - COPING - WASHED OUT MORTAR. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION - PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF MISSING COOKING STOVE. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | NORTH ,SOUTH AND EAST ELEVATIONS - LOOSE ,TANGLED PHONE AND CABLE LINES.SOUTH SIDE OF GARAGE HIGH WEEDS AND WEED TREES. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRY DOOR ROTTED AT BASE WORN FINISH. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED DETECTORS. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | WEST ELEVATION - CORNICE - WASHED OUT MORTAR. | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | CORRODED RECEPTACLES AND SWITCHES 1ST FLOOR VARIOUS | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | OPEN AIR SPLICED EXTENSION CORD RUN THROUGH GARAGE DOOR AND ATTACHED TO EXTERIOR LIGHT FIXTURE REMOVE UNAPPROVED CORDS WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT OF PROPERTY CONCRETE STAIRS BROKEN AND FRACTURED STEPS (14X-3-303.1.1) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | NO APPARENT BOX AT LIGHT FIXTURE FRONT FOYER, FLEXIBLE METAL CONDUIT NOT ATTACHED TO BOX AT 1ST BATH CEILING ENSURE GROUND CONTINUITY WHERE REQUIRED THROUGHOUT DANGEROUS AND HAZARDOUS | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | OBTAIN PERMIT BEFORE CONSTRUCTING ALTERING OR USING PLUMBING SYSTEM | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT (14A-5-505.2) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View | |
STOP LEAKING WATER | WATER LEAKING IN 1ST FLOOR BATHROOM FROM UNKNOWN SOURCE AT 2ND FLOOR BATHROOM OBSERVED THROUGH 1ST FLOOR BATHROOM DROP CEILING | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES WHERE REQUIRED AT 1ST FLOOR APARTMENT AND THROUGHOUT TO MEET MINIMAL REQUIRED | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT VIOLATIONS (14A-4-404.6) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View | |
MAINTAIN WINDOW | BOARDED BASEMENT WINDOWS (14X-3-303.13) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
RATS | SEVERE RAT INFESTATION VISIBLE FROM REAR ENCLOSED PORCH (14X-1-103.3.5) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OF PROPERTY ENCLOSED PORCH SYSTEM STAIRS LEANING REPAIRS REQUIRED (14X-3-302.3) REAR ENCLOSED PORCH 1HR FIRE SEPARATION REQUIRED FOR ALL WALLS UNDER STAIRS AND ALL AREAS PERTAINING TO THIS STRUCTURE | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | UNAPPROVED, EXCESSIVE, UNSUPPORTED FLEXIBLE METAL CONDUIT REAR INTERIOR STAIRS REMOVE WHERE REQUIRED (14E-3-348.10) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | DAMAGED WIRING VISIBLE AT OPEN BOX 1ST FLOOR BATH CEILING REPLACE WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BROKEN LIGHT FIXTURE AT REAR EXTERIOR REPLACE/REPAIR WHERE REQUIRED THROUGHOUT PREMISES | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED ACCORDION STYLE PVC TUBULAR DRAINAGE PIPING AT 1ST FLOOR BATHROOM LAVATORY | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PROVIDE | 1ST FLOOR BATHROOM IS LACKING PROPER VENTILATION BECAUSE WINDOW IS PAINTED SHUT AND UNABLE TO OPEN WITH NO EXHAUST FAN PRESENT | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH EAST CHIMNEY MISSING MORTAR (14X-303.1.1) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN BOX WITH HANGING WIRES AT 1ST FLOOR BATH CEILING CLOSE WHERE REQUIRED THROUGHOUT DANGEROUS AND HAZARDOUS | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED PLASTIC FLEXIBLE WATER PIPING AT 1ST FLOOR KITCHEN SINK | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FULL INTERIOR INSPECTION REQUIRED FOR THE ENTIRE PROPERTY,ACCESS TO 1ST FLOOR ONLY AT TIME OF INSPECTION (14A-1-104.7) | 6221 S CAMPBELL AVE | COMPLAINT | FAILED | View |