POST OWNER/MANAGERS NAME/# | BUILDING MISSING OWNERS I D SIGN. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
REPAIR ROOF | SOUTH ELEVATION,FRONT PORCH UNDER-SIDE,ROTTED PLYWOOD. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS,SIDING PEELING PAINT,FRONT PORCH SIDING IS LOOSE AND HANGING.WASHED OUT MORTAR AT GRADE,ALL ELEVATIONS. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION,2ND FLOOR,WINDOW FRAME MISSING ALUMINUM CAPPING. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION,SERVICE WALK,CRACKED CONCRETE AT SEWER COVER. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTH ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING GUARD RAIL,20'' DROP. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION,FRONT PORCH GRADE TO 1ST FLOOR,RAILS ARE 36'' LOOSE AND PULLING,DECKING PLYWOOD ROTTED,STAIR TREADS SPLKITTING AND RITTED,UNABLE TO INSPECT PORCH FRAMING MEMBERS,AREA ENCLOSED.NORTH ELEVATION,REAR PORCH GRADE TO 2ND FLOOR 6 BY 6 AND 4 BY 4 COLUMNS SET ON CONCRETE BLOCKS FOUNDATION STATUS UNKNOWN,JOISTS ARE FACE NAILED ONLY,STRINGERS ARE FACE NAILED ONLY,LEDGER FACE NAILED TO BUILDING,RAILS ARE LOOSE AND PULLING,DECKING BOARDS SPLITTING WITH NAILS POPPING,STAIRS WITH VARYING RISER HEIGHT OF 6 AND 10 INCHES.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,MISSING SMOKE DETECTOR. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST FLOOR HALLWAY,EXPOSED WIRES. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
REMOVE UNUSED OIL DRUMS/TANKS | FRONT HALLWAY,3-PROPANE TANKS BEING STORED. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | FRONT INTERIOR STAIRS,BIKES,BOXES,PROPANE TANKS,STORED . | 3450 W 62ND PL | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR REAR UNIT-ROOM TEMPERATURE-60F.HEATING SYSTEM IS OFF AT TIME OF INSPECTION,NO HEAT PROVIDED. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2ND FLOOR REAR UNIT-SPACE HEATER -OUT OF SERVICE AT TIME OF INSPECTION. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR REAR UNIT.USING PORTABLE ELECTRIC SPACE HEATERS FOR HEAT. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ATTIC WINDOW,BOARDED UP,NORTH ELEVATION 1ST FLOOR BROKEN PANE. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
CHIMNEY | WEST CHIMNEY,WASHED OUT MORTAR. | 3450 W 62ND PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND COMPLAINT OF 1ST FLOOR UNIT RODENT INFESTED,SEWER PROBLEMS,SINK BACK UP. | 3450 W 62ND PL | COMPLAINT | FAILED | View |