Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
REPAIR FENCE REAR FENCE - BROKEN; LEANING; TOP RAIL PROTRUDING AND OBSTRUCTING REAR EXIT 524 E 41ST ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR FENCE - BROKEN; TOP RAIL PROTRUDING OBSTRUCTING REAR EXIT 524 E 41ST ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT CONCRETE STAIRS - BROKEN, CHIPPED, CRACKED CONCRETE TREADS EXPOSING REBAR; SEVERE FRACTURES; TRIP/FALL HAZARD 524 E 41ST ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT SOME COLUMNS; CRACKED RISERS FROM GRADE TO 2ND FLOOR; LOOSE DECKBOARD AT 2ND FLOOR DECCK. PERMIT REQUIRED TO REPAIR REAR PORCH. 524 E 41ST ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT INTERIOR, STAIRWELLS, AND APARTMENTS. UNVERIFIED DETECTORS AND CONDITIONS. 524 E 41ST ST COMPLAINT FAILED View
REPAIR DOWNSPOUT SOUTH ELEVATION AT 530 / DOWNSPOUT - MISSING BOTTOM 6 FOOT SECTION. 524 E 41ST ST COMPLAINT FAILED View
REPAIR FLOOR APT. - 2A / 2ND FLOOR FRONT BEDROOM / FLOOR UNEVEN AT CLOSET ( HUMP UNDERNEATH CARPETING). DOOR RUBS ON FLOOR AND DAMAGED CARPETING. 524 E 41ST ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM SOUTH ELEVATION / STEEL AND CONCRETE PORCHES AT 524, 526 AND 530 / STEEL STRUCTURE - SEVERLY RUSTED AND DETERIORATED. CONCRETE TREADS - SPALLING MASONRY WITH EXPOSED RUSTEDED AND DETERIOARTED REBAR. PLANS AND PERMIT TO REPAIR STEEL AND CONCRETE PORCHES. SUBJECT TO FIELD INSPECTION BY IRON BUREAU. NORTH ELEVATION / 2 STORY WOOD PORCH / SOME GUARD RAILS - MISSING BRACKETS. DECK COVERED WITH GREEN ALGEA. WESTERN GUARD RAIL - LOOSE ANT BOTTOM. 524 E 41ST ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT. - 2A / REAR BEDROOM WALLS AND CEILING - WATER DAMAGE. 524 E 41ST ST COMPLAINT FAILED View
CARPETING APT. - 2A / 2ND FLOOR BEDROOM / CARPET - STAINED. FRONT BEDROOM CARPET TORN AT BIFOLD DOOR. 524 E 41ST ST COMPLAINT FAILED View