Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH-FLIGHTS SHIFT FROM SIDE TO SIDE UPON LOAD. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. ONLY PERMIT REQUIRED FOR REPAIRS. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-MISSING A MAILING ADDRESS. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH 3RD FLOOR COLUMN TO BEAM CONNECTION METAL STRAP 2ND FLOOR AND 1ST FLOOR REPAIR NO PERMIT NEEDED | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED COMPLAINT OF: SR#101090352-FLAMMABLE MATERIALS STORED, LIKE WOOD AND MACHINERY WITH GASOLINE IN THEM. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING JOIST HANGERS NO PLANS NEEDED NO PERMIT NEEDED TO REPAIR | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT OF BUILDING/ EXTERIOR WALLS - SOME WASHED OUT MORTAR JOINTS ON MASONRY CORNICE, SILL AND CAPPING STONES. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRS / TOP OF RETAINING WALL - MISSING GUARDRAILLING SYSTEM. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING JOIST HANGERS NO PLANS NEEDED NO PERMIT NEEDED TO REPAIR | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ REFUSED ENTRY, UNVERIFIED DETECTORS OCCUPANCY, AND CONDITIONS | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH GRADE TO 3RD FLOOR FROM 6224 TO 6226 4X4 COLUMNS AT RAMP ERECTED ON DIRT AND SIDE WALK FOUNDATION STATUTS UNKNOWN.2X8 JOIST 1ST 2ND AND 3RD SPAN 13' SPAN..2X8 NAILED TO HEADER..6X6 LAP12" WITH 2 BOLTS.GUARD RAILS1ST FLOOR RAMP. LOOSE . GUARD RAILS SECTIONS SPAN 13' SPAN.PLANS AND PERMIT REQUIRED FOR REPAIRS REAR PORCH..GUARD RAILS AND STRINGERS NAILED TO HEADERS STRINGERS AND WALL. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING OWNER ID NOT POSTED FROM 2009 TO 2017. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT COMPLETE. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING OWNER ID NOT POSTED FROM 2009 TO 2017. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT NORTH GRADE TO BASEMENT MISSING HAND RAIL. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH GRADE TO 3RD FLOOR FROM 6224 TO 6226 4X4 COLUMNS AT RAMP ERECTED ON DIRT AND SIDE WALK FOUNDATION STATUTS UNKNOWN.2X8 JOIST 1ST 2ND AND 3RD SPAN 13' SPAN..2X8 NAILED TO HEADER..6X6 LAP12" WITH 2 BOLTS.GUARD RAILS1ST FLOOR RAMP. LOOSE . GUARD RAILS SECTIONS SPAN 13' SPAN.PLANS AND PERMIT REQUIRED FOR REPAIRS REAR PORCH..GUARD RAILS AND STRINGERS NAILED TO HEADERS STRINGERS AND WALL. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | PLANS AND PERMIT# 100789457 ISSUED ON 10/24/2018 TO REPLACE REAR PORCH NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. SUBJECT TO FIELD INSPECTION AND APPROVAL BY CONSERVATION BUREAU. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT NORTH GRADE TO BASEMENT MISSING HAND RAIL. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ REFUSED ENTRY, UNVERIFIED DETECTORS OCCUPANCY, AND CONDITIONS | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT COMPLETE. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION OF REAR PORCH/ 3RD FLOOR - POWER LINE WITHIN REACH AND MISSING SCREENING. | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REPAIR OR REPLACE | LOOSE HANDICAP RAMP AT THE STOOP / THRESHOLD OF THE REAR ENTRANCE TO THE APARTMENT (SEC.7-28-060). | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |
REMOVE | BARBEQUE GRILL ON THE 3RD FLOOR LANDING (SEC.7-28-060). | 6224 S KIMBARK AVE | PERIODIC | FAILED | View |